B13 LIFT ARM
FOOT
CONTROL
WARNING
LIGHTS
CAB CUT OFF SWITCH
CONTROL
BOX
HAND
REMOTE
POWER PACK
GROUND for PC BOARD
(green/yellow and black # 1)
POSITIVE for PC BOARD
(black #2 to 2
and black # 4 to 27)
CYLINDERS
LIFT 15 (2 ea)
TILT 14 (2 ea)
BL - Blue
BR - Brown
SW - Black
GE - Yellow
GN - Green
- Negative
+ Positive
AUX port
Power LED
B15 PLATFORM
Control Board Codes:
System ok / Cab switch off, (or missing bridge J11/2<->4)
System ok / Cab switch on, (or bridge J11/2<->4)
Low Voltage
Missing tilt switch B-13 at lift arm or defective.
Missing tilt angle sensor B-15 at lift platform or defective
Missing tilt angle sensor B-15 at platform or defective
Warning lights shorted
Short in cab switch/on-off switch or aux port
General short in electrical wiring
Emergency program (all sensors are bypassed).
Activation by: Press Open+Lower>10 seconds
Diagnosis mode activated
Defect at motor solenoid detected during lifting
Voltage V02 (J1 pin 2) is missing, defective fuse
Defect at opening, valve (S3/S4) or motor relay
detected during opening
S5 valve detected during closing or motor solenoid defective
S5 valve detected or defect at lowering valve (S1/S2)
Cab switch: off/on (or disconnect bridge J11/2<->4)
Automatically when the valves are back to normal
Automatically when the valves are back to normal
Automatically when the valves are back to normal
Cab switch: off/on (or disconnect bridge J11/2<->4) or close
tail lift
Cab switch: off/on (or disconnect bridge J11/2<->4) or close
tail lift
Cab switch: off/on (or disconnect bridge J11/2<->4) or
voltage interruption MBB control
Cab switch: off/on (or disconnect bridge J11/2<->4)
Automatically when the valves are back to normal
Replace the fuse
Automatically when the valves are back to normal
Automatically when the valves are back to normal
Automatically when the valves are back to normal
Removing service connector
Code
Description
Reset
Figure 6.4: Electrical Wiring overview