background image

EN

www.pakole.com

Zenit70_009_004-006_01

1_210601_V004_EN

Appliance types:

ZENIT

 

70+

 

 

12...48 kW

PROPANE OR NATURAL GAS-FIRED  

ZENIT TUBE RADIANT HEATER

User’s Manual

Summary of Contents for ZENIT 70+

Page 1: ...EN www pakole com Zenit70_009_004 006_011_210601_V004_EN Appliance types ZENIT 70 12 48 kW PROPANE OR NATURAL GAS FIRED ZENIT TUBE RADIANT HEATER User s Manual...

Page 2: ...9 Electrical connection scheme of SIT 579 DBC automatic burner control 9 Optional accessories 10 Control of appliance 11 Protective distances 12 Combustion air supply 14 6 Air supply and venting syst...

Page 3: ...not play with devices ATTENTION Fire burning inhalation and explosion hazard Keep all flammable objects as follows building materials papers or carton unites away from heater according to the instruct...

Page 4: ...larly worn or damaged in that case exchange it for a new one specified by manufacturer Preserve the equipment in genuine condition do not leave it to grow old Do not use seriously aged equipment any l...

Page 5: ...fice or the closest dealer and ask for further informations ATTENTION COMPULSORY EARTHING ATTENTION ONLY QUALIFIED PERSON CAUTION DANGER CAUTION ELECTRIC SUPPLY According to the installation project i...

Page 6: ...d board box The unpacking process of the appliance unload the burner the tubes and the accessories from the card board box do not remove the protection cap from the burners gas connection or from the...

Page 7: ...tion Burner Combined hanger Radiant tube Reflector Isolation Spacer plate Isolation cover End cap Flue gas analyzer nozzle Lower clip Burner hanger Fresh air intake Burner fixing clamp Electric connec...

Page 8: ...THING Electrical connection The combustion air supply centrifugal fan is fixed to the appliance burner head the automatic burner control is located in the burner head in this way the electrical supply...

Page 9: ...re Connection points of SIT 579 DBC automatic burner control box Work out the electrical network system regarding to the diagram to the was attached to the appliance If the switcher position is 0 does...

Page 10: ...perature controllers for the appliance these can be purchased at the appliance manufacturer Optional accessories Thermostat 18 picture Temperature controllers FP 1D 2 point regulation thermostat FP 3D...

Page 11: ...sensation of temperature be continuously served during an economical operation That the reduced input can be 50 or 60 it depend on the length of pipes and the temperature of exiting combustion product...

Page 12: ...ust comply with the valid standards Disregard of these instructions can result in death injury or property damage Protective distances Protective distances to be kept considering flammable materials 2...

Page 13: ...tch and maximum angle of combustion and radiant tubes always 0 Example for location of suspensions ZENIT Tube location Minimum installation height for input power 10 kW 15 kW 20 kW 25 kW 30 kW 35 kW 4...

Page 14: ...ystem In this case the combustion air must be conducted to the device from the external space Example for outside combustion air supply Tube length for combustion air supply 6 meter with one elbow fro...

Page 15: ...e longer flue gas pipe can also be employed In such cases the maximum equipment length the fume discharge can be 30 meters in aggregate but the flue gas pipe section above 6 meters must always be heat...

Page 16: ...f the flame control of burner automation does not register flame during the safety time than repeats the all ignition procedure maximum two times If in this time there is not registered flame then it...

Page 17: ...that the load is distributed smoothly at all mountings You can check it moving each hanger a little e Cleaning the flue pipes Remove the barrier by the combustion product and reset the original condi...

Page 18: ...ion of combustion air fan Check whether the wheel of fan is able to revolve free and remove the possible contaminations from revolving blades Maintenance supervisions by a qualified service department...

Page 19: ...x x ZENIT 70 18 18 7 x x x x ZENIT 70 20 20 x x x x ZENIT 70 22 22 7 x x x x ZENIT 70 24 24 2 x x x x ZENIT 70 26 26 x x x x x x ZENIT 70 28 28 2 x x x x x x ZENIT 70 30 30 3 x x x x x x ZENIT 70 32...

Page 20: ...ENIT 70 18 11 18 7 11 6 x x x x ZENIT 70 20 12 20 12 6 x x x x ZENIT 70 22 12 22 7 12 8 x x x x ZENIT 70 24 14 24 2 14 8 x x x x ZENIT 70 26 15 26 15 9 x x x x x x ZENIT 70 28 16 28 2 16 3 x x x x x x...

Page 21: ...4 09 3 95 Type Input power kW Gas consumption m3 h kg h Natural gas Propane Butane Propane ZENIT 70 12 12 6 8 9 1 32 0 93 1 05 0 74 1 02 0 72 ZENIT 70 14 14 8 9 9 1 55 1 04 1 24 0 83 1 2 0 8 ZENIT 70...

Page 22: ...0 Minimum heat output as percentage of nominal heat output 62 0 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 60 2 Envelope insulation class U 0 0 W m2K Radiant factor at m...

Page 23: ...0 Minimum heat output as percentage of nominal heat output 61 0 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 61 6 Envelope insulation class U 0 0 W m2K Radiant factor at m...

Page 24: ...0 Minimum heat output as percentage of nominal heat output 63 0 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 63 2 Envelope insulation class U 0 0 W m2K Radiant factor at m...

Page 25: ...Minimum heat output as percentage of nominal heat output 61 0 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 64 3 Envelope insulation class U 0 0 W m2K Radiant factor at mi...

Page 26: ...0 Minimum heat output as percentage of nominal heat output 62 0 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 65 2 Envelope insulation class U 0 0 W m2K Radiant factor at m...

Page 27: ...0 Minimum heat output as percentage of nominal heat output 62 0 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 66 1 Envelope insulation class U 0 0 W m2K Radiant factor at m...

Page 28: ...0 Minimum heat output as percentage of nominal heat output 62 0 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 60 7 Envelope insulation class U 0 0 W m2K Radiant factor at m...

Page 29: ...90 Minimum heat output as percentage of nominal heat output 61 0 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 62 1 Envelope insulation class U 0 0 W m2K Radiant factor at...

Page 30: ...0 Minimum heat output as percentage of nominal heat output 63 0 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 63 7 Envelope insulation class U 0 0 W m2K Radiant factor at m...

Page 31: ...20 Minimum heat output as percentage of nominal heat output 61 0 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 64 6 Envelope insulation class U 0 0 W m2K Radiant factor at...

Page 32: ...0 Minimum heat output as percentage of nominal heat output 62 0 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 65 8 Envelope insulation class U 0 0 W m2K Radiant factor at m...

Page 33: ...10 Minimum heat output as percentage of nominal heat output 62 0 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 66 5 Envelope insulation class U 0 0 W m2K Radiant factor at...

Page 34: ...y not authorized retailer or service station The regular maintenance is the owner s responsibility The manufacturer does not assume the responsibility in case of accidentally happened or directly caus...

Page 35: ......

Page 36: ...PAKOLE TRADE Ipari s Kereskedelmi Kft H 8000 Sz kesfeh rv r B rg ndi t 8 10 www pakole com mail pakole hu Tel 36 22 316 484 www pakole com...

Reviews: