Pakole LLV-400 Instructions For Installation And Servicing Download Page 4

LLV 

Air destratifier ventilator family

 

Instructions for Installation and Servicing

4

• 

Make sure you have read and understood all the warnings, the exact observance of which guarantees safe and perfect opera-

tion! 

• 

Always use caution when using the device! Follow the regional regulations and recommendations!  

• 

Use the device only at the electrical voltage and frequency indicated on the nameplate! The electrical connections and earthing 

have been designed in accordance with EN 60335! 

• 

Electrical grounding requirements: this appliance is equipped with a three-point (earthed) connector for your protection! 

• 

Keep the unit away from the following strong impacts: wind, high-pressure water jet, rain or dripping water! The equipment can-

not be used in outdoor!

• 

Always check the appliance for damage before starting it� Never use damaged equipment!  

• 

Keep the appliance in its original condition, do not allow it to age! 

• 

Do not use severely obsolete equipment!

 

• 

Hang the device from a stable surface that maintains its stability during operation despite the device warming up!

• 

If the appliance is not used, always disconnect it from the power supply!

• 

Never block the air intake and exhaust vents!

• 

Never service equipment that is in operation or under electrical load!  

• 

Never attach an air duct element to the front or back of the appliance that is not approved by the manufacturer!

• 

Use only original spare parts approved by the manufacturer, do not install replacement parts with the same operating character-

istics as the original part�  Such replacement parts can cause serious damage to the operation of the system!

The device is equipped with a data board, which is located on the outside of the device� The data board contains information on the type 

of appliance, the type of gas and the electrical connection� For example: 

1. figure: Data board

2.

  

General instruction

Data board

• 

Construction of electrical connections in accordance with regulations,

• 

installation of the device according to the arrangement specified in this manual,

• 

installation in accordance with fire protection regulations,

• 

providing materials for installation (not included in the device),

• 

performing the service, providing the Owner with a copy of this Manual,

• 

ensuring satisfactory air circulation around the device,

Installer’s responsibilities

11435 m³/h

Airflow:

0,75 kW

Type

Electrical power:

Series number:

IP protection:
Electrical connection:

Max.current entry:

IP40

AC 230V, 50Hz, 1 Ph.

Date/place of 

production

15.02.2021

102-9334-135

14 A

GB

Targeted country:

PAKOLE Trade Kft.

8000 Székesfehérvár, 

Börgöndi út 8-10.

Manufacturer

LLV-650

2806 20

9400  m

3

/h

THE DEVICE HAS BEEN MANUFACTURED IN ACCORDANCE WITH DIRECTIVE 2014/35/EU.

!

Summary of Contents for LLV-400

Page 1: ...AIR DESTRATIFIER VENTILATORS EN www pakole com Appliance types LLV 400 LLV 450 LLV 500 LLV 650 LLV 800 LLV_008_036_011_220628_V004_EN instructions for installation and servicing For qualified persons...

Page 2: ...l data 8 Direction of airflow 9 6 Appliance installation 9 Installation distances 10 Electrical connection 10 Connecting cable data 11 Electrical wiring 11 Connection of the speed controller 11 Decomm...

Page 3: ...may result in seri ous injury or property damage The appliance may only be used by persons who have understood and followed the instructions in the Installation and Maintenance Manual If you need help...

Page 4: ...rical load Never attach an air duct element to the front or back of the appliance that is not approved by the manufacturer Use only original spare parts approved by the manufacturer do not install rep...

Page 5: ...essional examination in the field as well as has participated in the mandatory annual training organized by manufacturer Call your nearest reseller for information ATTENTION COMPULSORY EARTHING ATTENT...

Page 6: ...its type corresponds to the type ordered All devices are shipped from the factory after testing so if you notice any damage notify your carrier immediately Transporting unpacking and packing the devic...

Page 7: ...al mode the device can be started at any time with the help of a switch so the device can also be used for ventilation and air circulation The direction of the blow out can be set within certain limit...

Page 8: ...Engine power consumption W 180 250 420 750 1036 Power consumption A 0 82 1 2 1 95 3 5 4 5 Electrical protection IP40 IP40 IP40 IP40 IP40 Net weight Kg 15 8 18 2 19 7 46 5 54 Electrical connection 230V...

Page 9: ...TION MUST ALWAYS BE CARRIED OUT IN ACCORDANCE WITH LOCAL LEGISLATION Type LLV 400 LLV 450 LLV 500 LLV 650 LLV 800 Length of lamella mm 515 590 590 850 850 Pieces of lamella pcs 2x4 2x4 2x4 5 7 Slats e...

Page 10: ...er modification to the product will void the warranty Mark the location of the 4 wall plug on the floor Make 4 holes for the wall plugs Secure the chains on which the device is suspended with 4 M8 ten...

Page 11: ...um opening of 3 mm check the current value on the rating plate on the appliance to select the correct switch A multi pole switch is actually a bi polar insulated switch meaning the switch is suitable...

Page 12: ...LIANCE WITH ANY OBJECT OR CURTAIN THAT COULD PREVENT FREE AIR FLOW ATTENTION When operating the appli ance do not place any objects or clothing in front of the air outlet as this may block the air out...

Page 13: ...Again it should be noted that the installation and adjustment tests of the equipment may only be carried out by a qualified person Failure to do so will void the warranty and the manufacturer will not...

Page 14: ...r other deposits Check that the fan is running without vibration or noise and that the suction or dis charge flow is not obstructed to avoid overheating the motor winding Check the fan housing for dep...

Page 15: ...take exhaust side Remove the obstruction The fan rotates in the opposite direction Check the wiring diagram and the connections Excessive airflow Install the unit higher Low static pressure The fan ro...

Page 16: ...tear modification modification factors affecting operation use due to contaminated fuel installation of unsuitable parts repair by a non service center or dealer Regular maintenance is the responsibil...

Page 17: ...LLV Air destratifier ventilator family Instructions for Installation and Servicing 17...

Page 18: ...PAKOLE TRADE Ltd H 8000 Sz kesfeh rv r B rg ndi t 8 10 www pakole hu mail pakole hu Tel 36 22 316 484 www pakole com...

Reviews: