Pakedge MS Series User Manual Download Page 1

 

 

MS Series  

LAYER 3 SWITCHES WITH OVRC 

MS-1212, MS-2424, MS-2400, MS-2416, MS-4424 

 

User Guide  

Summary of Contents for MS Series

Page 1: ...MS Series LAYER 3 SWITCHES WITH OVRC MS 1212 MS 2424 MS 2400 MS 2416 MS 4424 User Guide...

Page 2: ...witch 8 Navigating the switch 8 Tabs 9 Tab layouts 9 Tiles and sub tabs 10 Table content 10 Viewing adding and editing 11 Editing multiple items 12 Configure 13 Overview 14 Connections 15 Interfaces 1...

Page 3: ...s 35 Reset to factory default settings 36 Reset using the interface 36 Reset using the physical RESET button 37 Advanced 37 Configuring IGMP Snooping 38 Enabling VLAN IGMP snooping status 40 Configuri...

Page 4: ...ion If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interfer...

Page 5: ...s PoE 2 10G SFP MS 2424 Pakedge L3 Managed Switch 44 1G 24 PoE 370W 4 10G SFP MS 4424 Switch specifications Managed switch SKU Total of ports Ports with no PoE support Ports with PoE Power budget SFP...

Page 6: ...flow required for safe operation of the equipment is not compromised Caution If you install the switch in a closed or multi unit rack assembly the operating ambient temperature of the rack environment...

Page 7: ...Rack mount set Quick Start Guide Front panel LED Type LED Color LED Definition Power LED Blue Solid Blue Device is on Flicker Blue Device is booting Off Device is off PoE Ethernet port LED Blue Amber...

Page 8: ...ck panel Reset button press Result 5 seconds 10 seconds On button release between 5 and 10 seconds Set login username password to default 10 seconds On button release after 10 seconds Revert to firmwa...

Page 9: ...el and MAC address of the switch and note the corresponding IP address obtained by the switch 4 Navigate to the IP address listed in the router DHCP table for the switch 5 Enter the Username and Passw...

Page 10: ...settings Port VLAN PoE Backup Save a configuration backup and then restore a configuration file Logs Displays a sortable record of system events affected by the switch n a Advanced Less often used or...

Page 11: ...b categories it is divided into Tiles and Sub tabs On these tabs select a tile and sub tab to view its tables Table content From the open table monitor edit or add specific switch settings The rest of...

Page 12: ...ays above the table To change a switch setting access a tab click its More icon then click Add Edit or Delete Complete the dialog then click Apply at the top of the page to finalize your changes Impor...

Page 13: ...ore icon upper right and click Edit An edit check box appears next to each item 3 Select the edit checkbox next to each item you want to edit then click Edit Selected Caution Editing multiple items re...

Page 14: ...switch a descriptive name to identify it on its web interface screen Device Location Describe the physical location of the switch here Device Notes List any other useful information about the switch...

Page 15: ...the switch you will see a message alerting you with an option to download it Notifications System notifications display at the very top of the tab This example shows a firmware update is available De...

Page 16: ...to sort the list by that field Available fields are Interface Physical interface on the switch Name Device name assigned by the user Link Status Link speed status of the interface IP Address IP addres...

Page 17: ...e switch s physical and virtual interfaces and PoE settings port VLAN and PoE settings Tiles The Interfaces tab opens to three tiles Ports VLANs and PoE Add or edit an interface To add or edit an inte...

Page 18: ...ck Apply to save and apply your changes Important Your changes will not be saved until you click Apply Completing the dialog Depending on the selected interface you will see different editing options...

Page 19: ...switch port settings Choose from two sub tabs Port Summary View or configure key port settings including the port name port status enable disable various modes and configure autonegotiation Port Deta...

Page 20: ...to negotiation and other settings Edit To edit available Port Summary settings 1 Log in to the switch then click Interfaces Port Port Summary 2 Click More then click Edit 3 Check the box next to items...

Page 21: ...s the port speed and duplex mode for physical interfaces The physical status for LAGs is not reported STP Mode Enable Disable The Spanning Tree Protocol STP Administrative Mode associated with the por...

Page 22: ...example Touch Screen Camera Controller To edit port names 1 Log in to the switch 2 Click Interfaces Port Port Details 3 Click the More icon and click Edit 4 Select the check box next to items you wan...

Page 23: ...active VLANs and create new VLANs Switchport Configuration View edit each switchport Interface Name Switchport Mode Native VLAN and Tagged VLANs Reset Return VLAN configuration parameters to their de...

Page 24: ...VLAN Data Base To edit a VLAN in the VLAN database 1 Go to Interfaces VLAN VLAN Database 2 On the upper right click the More icon 3 Click Edit 4 Complete the dialog then click Apply to save your work...

Page 25: ...switchport settings per port Select Switchport Mode Access or Trunk Edit Switchport Configuration To edit Switchport Configuration 1 Select Interfaces VLAN Switchport Configuration 2 Click the More ic...

Page 26: ...of the interface which is one of the following Access Access mode is suitable for ports connected to end stations or end users Access ports participate only in one VLAN They accept and transmit untagg...

Page 27: ...on the port 1 Priority Default 802 1p priority assigned to untagged packets arriving at the interface 0 VLAN Subpage Reset To access the VLAN reset feature go to Interfaces VLAN Reset From the Reset...

Page 28: ...t Select a port Name Priority Power Mode Power Limit General View configure additional port settings o Set the port s System Threshold enable disable Power Management Mode and Traps Statistics View on...

Page 29: ...tion Enable Indicates whether PoE is enabled disabled on the interface Interface Interface associated with the data in the row Name Name associated with the Interface on the row Priority Priority of t...

Page 30: ...o save your changes Completing the dialog See below for help completing the Edit Port Configuration dialog Explanations Edit Port Configuration dialog Title Function Input values validation Default En...

Page 31: ...ld only need to be modified for compatibility with old endpoint devices Legacy 4Pt Dot3af 4Pt Dot3af Legacy 2Pt Dot3af 2Pt Dot3af Legacy None 4Pt Dot3af Timer Schedule The time range from the list of...

Page 32: ...Threshold percent Consumed Power The amount of power in mW currently being consumed by connected PoE devices System Usage Threshold Click to type A percentage of the total power available This percen...

Page 33: ...row Name The name associated with the Interface on the row Overload Counter Number of times there has been a power overload Short Counter Number of times there has been a short circuit condition Powe...

Page 34: ...nations Title Input type Function Interface View Only Interface associated with the rest of the data in the row Name View Only User assigned name for the interface on the row High Power View Only Indi...

Page 35: ...w Only Current powering status of the interface Fault Status View Only Fault information if any Backup The Backup tab allows you to save a configuration backup and restore the configuration file Save...

Page 36: ...one time To clear or refresh the log 1 In the Logs tab click the OPTIONS button then click Clear Logs or Refresh Logs The log file is cleared or refreshed To download the log 1 In the Logs tab click...

Page 37: ...using the interface To only restart the switch maintaining all settings 1 In the Overview or Connections tab click Restart Device The switch restarts To reset to factory default settings deleting all...

Page 38: ...IGMP Snooping settings per VLAN interface IGMP Snooping Querier Manage configure and monitor IGMP Snooping Querier settings Set the query interval configure VLAN query settings and view VLAN status U...

Page 39: ...rdance with the IEEE MAC Bridge standard Eventually the packet is made accessible to all nodes connected to the network This approach works well for broadcast packets that are intended to be seen or p...

Page 40: ...the Admin Mode button to Enable or Disable IGMP Snooping globally The default is disabled This must be enabled before configuring IGMP Snooping per VLAN interface Multicast Control Frame Count Shows t...

Page 41: ...ive multicast packets directed to the group address Fast Leave Admin Mode The administrative mode of Fast Leave on the VLAN If Fast Leave is enabled the VLAN can be immediately removed from the Layer...

Page 42: ...e options are as follows Enabled Only the first IGMP report from all hosts for a group IGMP report is forwarded to the multicast routers Disabled The device forwards all IGMP reports from all hosts in...

Page 43: ...Guide 42 Configuring multicast router VLANs To configure multicast router VLANs 1 In the IGMP Snooping screen click the Multicast Router VLAN Configuration tab The Multicast Router VLAN Configuration...

Page 44: ...MS Series User Guide 43 2 Click to select the interface to change then click Edit Selected The Edit Multicast Router VLAN Configuration screen opens...

Page 45: ...s to establish appropriate forwarding IP Address The snooping querier address to be used as source address in periodic IGMP queries This address is used when no IP address is configured on the VLAN on...

Page 46: ...VLAN that is being configured Querier Election Participation The participation mode for the IGMP snooping querier election process Enabled The IGMP snooping querier on this VLAN participates in the qu...

Page 47: ...VLAN Status Use this page to view information about the IGMP snooping querier status for all VLANs that have the snooping querier enabled 1 In the IGMP Snooping Querier screen click the VLAN Status t...

Page 48: ...ned for the multicast addresses within 224 0 0 x will continue to flood with Drop set to Enabled as these groups are required for IGMP messaging Exception List Name Displays the default ACL exception...

Page 49: ...A THROUGH THE SWITCH TO STOP AND ACCESS TO BE BLOCKED CONSOLE ACCESS WOULD BE REQUIRED TO REGAIN ACCESS WITHOUT A FACTORY RESET TO DEFAULTS Seq no The ACL rule number for each exception entry Multicas...

Page 50: ...t modifications in the working but not the end effect chief among the effects is the rapid transitioning of the port to Forwarding The difference between the RSTP and the traditional STP IEEE 802 1D i...

Page 51: ...tocol MSTP includes all the advantages of RSTP and also supports multiple spanning tree instances to efficiently channel VLAN traffic over different interfaces MSTP is compatible with both RSTP and ST...

Page 52: ...ackets This prevents a new device from entering the existing STP topology so devices that were originally not a part of STP are not allowed to influence the STP topology BPDU Filter When enabled filte...

Page 53: ...Port The port on the bridge with the least cost path to the designated root for the CST Max Age The amount of time a bridge waits before implementing a topological change Forward Delay The forward de...

Page 54: ...Cost The cost of the path from the port to the CIST root This value becomes important when the network includes multiple regions Port Mode The administrative mode of spanning tree on the port Auto Ed...

Page 55: ...devices that were originally not a part of STP are not allowed to influence the STP topology Port ID A unique value that is automatically generated based on the port priority value and the interface i...

Page 56: ...Inconsistent State Identifies whether the interface is currently in a loop inconsistent state An interface transitions to a loop inconsistent state if Loop Guard is enabled and the port stops receivi...

Page 57: ...iple bridges are equal the bridge with the lowest MAC address is elected as the root bridge Time Since Topology Change The amount of time that has passed since the topology of the MSTI has changed Des...

Page 58: ...t the port has been up since the counters were cleared Port Role The role of the port within the CST which is one of the following Root A port on the non root bridge that has the least cost path to th...

Page 59: ...tion about the number and type of bridge protocol data units BPDUs transmitted and received on each port 1 In the Spanning Tree screen click the Statistics tab The Spanning Tree Statistics screen open...

Page 60: ...egulatory notices and patent information at snapav com legal Copyright 2021 Wirepath Home Systems LLC All rights reserved Control4 and SnapAV and their respective logos are registered trademarks or tr...

Reviews: