FCC Compliance

This unit complies with the limits for Class B digital devices pursuant to Part 15 of the FCC rules. These limits 
are designed to provide reasonable protection against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not 
installed and used in accordance with the instruction manual, can cause harmful interference to radio 
communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which 
case the user will be required to correct the interference at his own expense.

Refer to the installation section of the appropriate instruction manual for the unit you are installing to get 
information on:

Cabling

Correct connections

Grounding

Modifications

The FCC requires the user to be notified that any changes or modifications made to this device that are not 
expressly approved by PairGain Technologies, Inc. may void the user's authority to operate the equipment.

All wiring external to the products should follow the provisions of the current edition of the National Electrical 
Code

A

BBREVIATIONS

2B1Q

2 binary bits encoded in one quaternary symbol

AWG

American Wire Gauge

CLASS

Custom Local Area Signaling Services

CO

Central Office

COT

Central Office Terminal

DS0

Digital Signal Level Zero (64 kb/s)

DTMF

Dual Tone Multi-Frequency

HDSL

High-bit-rate Digital Subscriber Line

MLT

Mechanized Loop Testing

PBX

Private Branch Exchange

PCM

Pulse Code Modulation

PGTC

Pair Gain Test Controller

POTS

Plain Old Telephone Service

RMA

Return Material Authorization

RT

Remote Terminal

Summary of Contents for PG-Flex FRC-754 L4

Page 1: ...ANNEL REMOTE TERMINAL LOOP START GROUND START POTS UNIT PAIRGAIN TECHNOLOGIES INC ENGINEERING SERVICES TECHNICAL PRACTICE 363 754 104 01J SECTION 363 754 104 01 Model List Number Part Number FRC 754 4...

Page 2: ...n contained in this document is company private to PairGain Technologies Inc and shall not be modified used copied reproduced or disclosed in whole or in part without the written consent of PairGain O...

Page 3: ...4 List 4 June 22 1998 iii USING THIS TECHNICAL PRACTICE Two types of messages identified by icons appear in the text Notes contain information about special circumstances Cautions indicate the possibi...

Page 4: ...Start Operation 4 Ground Start Operation 6 CLASS Features 7 Forward Disconnect 7 Installation and Test ___________________________________________________________________ 8 Unpacking 8 Installing 8 P...

Page 5: ...4 provides metallic access to the subscriber line connection through an optional metallic bypass pair Features of the PG Flex FRC 754 List 4 channel unit are eight loop start or ground start POTS sub...

Page 6: ...ough 8 Fast flashing green Channel is in test access mode Slow flashing green LED follows the ring signal Off Channel is on hook idle FAULT Red Fault detected by the unit See Table 10 on page 10 for t...

Page 7: ...Ringer Output 40 V RMS 3 lines simultaneously 5 REN each End to End Loss 2 5 dB 1 0 dB at 1004 Hz Lightning Protection Meets all requirements GR CORE 1089 Section 4 Environmental Operating Elevation 2...

Page 8: ...subscriber lines or ground start for PBX lines Each FRC 754 List 4 circuit has an associated LED that indicates when the line is off hook idle ringing or under test see Table 1 on page 2 Loop Start Op...

Page 9: ...rcuit interactions Table 3 Circuit Interactions When a Subscriber Initiates an Outgoing Call Loop Start Operation CO Switch FRC 754 List 4 COCU FRL 754 List 4 RTCU Subscriber CO Idle No ringing No rin...

Page 10: ...d outgoing calls may occur simultaneously on the same line Glare occurs when both ends of a telephone line or trunk are seized at the same time CO sends dial tone and grounds the Tip to signal the PBX...

Page 11: ...s activated the CO generates analog signalling toward the PBX between the first and second bursts of the ringing signal Forward Disconnect The forward disconnect function releases a called line that w...

Page 12: ...do not follow the above sequence see Table 10 on page 10 2 After the system has powered up established HDSL synchronized communications and no calls are in progress verify that the channel unit front...

Page 13: ...ss of the call refer to Table 1 on page 2 for front panel indications Place an incoming call to each subscriber circuit provisioned and verify that the ACTIVE LED tracks the progress of the call refer...

Page 14: ...still not present replace the RT Line Unit 3 If ringing is still not present at the RT reinsert the original Channel Unit and Line Unit Test for ringing at the COT 4 Test for ringing into the COT fro...

Page 15: ...ransmission speeds up to 28 8 kbps are supported with a character format of 8 N 1 Warranty PairGain Technologies warrants this product to be free of defects and to be fully functional for a period of...

Page 16: ...ppropriate instruction manual for the unit you are installing to get information on Cabling Correct connections Grounding Modifications The FCC requires the user to be notified that any changes or mod...

Page 17: ......

Page 18: ...Corporate Office 14402 Franklin Avenue Tustin CA 92780 Tel 714 832 9922 Fax 714 832 9924 For Technical Assistance 800 638 0031...

Reviews: