PairGain PG-Flex 8 FLC-704 Manual Download Page 6

Section 363-704-102-02

January 12, 1998

Revision 02

Page 4

PairGain Engineering - Plant Series

PG-Flex FLC-704 List 2

B. FUNCTIONAL DESCRIPTION

4.  Applications

4.1

PG-Flex is a small capacity universal subscriber carrier system that can support up to 32 DS0
subscriber channels, including POTS and ISDN services.  The system is based on HDSL transmission
technology and is remotely powered from the Central Office (CO).  Using two 24 gauge (0.5mm)
unconditioned copper pairs, the remote terminal may be located up to 10.7 kft (3.3 km) from the
Central Office Terminal (COT).  Standard 19- or 23-inch shelves contain multiple systems; circuit
cards may be hot-swapped without affecting other systems installed in the shelf.  POTS channel units
use 64-kbps A-Law pulse coded modulation (PCM) encoding to allow Group 3 facsimile or high-
speed modem operation on all channels.

4.2

System Flex Configuration. Figure 2 shows a typical PG-Flex system that consists of:

• 

COT.  Two complete systems may be installed in a 19-inch COT Shelf and four complete
systems may be installed in a 23-inch COT Shelf.  Each system requires one COT Line Unit and
up to three (23-inch shelf) or six (19-inch shelf) Channel Units.  A common Alarm Unit or Pair
Gain Test Controller Interface Unit in each shelf provides an interface for maintenance alarm
relays and metallic access to the remote subscriber lines.

• 

RT.  The RT Enclosure provides a weatherproof housing for the PG-Flex remote electronics and
subscriber terminations.  The enclosure accepts one common RT Line Unit and up to four
Channel Units. The RT communicates with, and is line-powered from, the COT over two pairs of
19 AWG to 26 AWG (0.9 mm to 0.4 mm) twisted-pair telephone wire.  Each pair carries both
power and HDSL signaling.

Figure 2.  Typical PG-Flex Configuration.

Summary of Contents for PG-Flex 8 FLC-704

Page 1: ...704 Model List Number Part Number CLEI Code FLC 704 2 150 1304 02 N A PAIRGAIN TECHNOLOGIES INC ENGINEERING PLANT SERIES TECHNICAL PRACTICE SECTION 363 704 102 02 Revision History of this practice Re...

Page 2: ...S TECHNICAL PRACTICE Two types of messages identified by icons appear in the text A note informs you of special circumstances Cautions indicate the possibility of damage to equipment or the possibilit...

Page 3: ...C 704 Channel Unit includes green status LEDs for each line indicating idle ringing and off hook conditions as well as a red LED indicating a fault condition The channel unit provides metallic test ac...

Page 4: ...dications for the FLC 704 Channel Unit front panel LEDs Figure 1 FLC 704 Front Panel Table 1 FLC 704 Front Panel LEDs LED LED State Indicates Solid green Channel is off hook ACTIVE Fast flashing green...

Page 5: ...OT End to End Loss 2 5 dB 1 0 DC Off Hook Current 30 mA Channel Signature Tip Ring 475 k 1 Tip Ground 332 k 1 Ring Ground open COT 20 Hz Input Impedance 0 5 REN Environmental Operating Elevation 200 f...

Page 6: ...Group 3 facsimile or high speed modem operation on all channels 4 2 System Flex Configuration Figure 2 shows a typical PG Flex system that consists of COT Two complete systems may be installed in a 19...

Page 7: ...the HDSL lines do not require any special conditioning and may include unterminated bridge taps but cannot include load coils Table 2 PG Flex Distances Loop Length Wire Gauge 16 32 Channel System Res...

Page 8: ...rd disconnect detects a subscriber test access signal detects metering tones provides loop closure 5 2 A block diagram of the FLC 704 Channel Unit is shown in Figure 3 One 8 Channel COT Channel Unit s...

Page 9: ...re the equipment for a prolonged period store the equipment in its original container 7 Turn Up and Testing 7 1 Install COT Channel Units 1 Insert each FLC 704 Channel Unit into the COT shelf All LEDs...

Page 10: ...resent at the RT re insert the original Channel Unit and Line Unit Test for ringing at the COT 4 Test for ringing into the COT from the CO switch If no ringing is present refer the trouble to the CO s...

Page 11: ...uestions This system is available 24 hours a day by calling 714 730 3299 Transmission speeds up to 28 8 kbps are supported with a character format of 8 N 1 E CERTIFICATION AND WARRANTY 10 Certificatio...

Page 12: ...ranty 11 3 If a unit needs repair call PairGain for a Return Material Authorization RMA number and return the defective unit freight prepaid along with a brief description of the problem to PairGain R...

Page 13: ...Revision 02 January 12 1998 Section 363 704 102 02 PG Flex FLC 704 List 2 PairGain Engineering Plant Series Page 11...

Page 14: ......

Reviews: