![PairGain HiGain SOLITAIRE H2TU-C-319 List 1 Technical Practice Download Page 24](http://html1.mh-extra.com/html/pairgain/higain-solitaire-h2tu-c-319-list-1/higain-solitaire-h2tu-c-319-list-1_technical-practice_3303800024.webp)
Provisioning
152-319-100-02, Revision 02
16
April 21, 2000
H2TU-C-319 List 1 and List 1C
Setting Circuit ID Numbers
The Inventory menu provides product information on all units in the system and allows setting of the circuit and
unit identification numbers.
Figure 6.
Inventory Screen
1
Press
to select the Inventory screen.
2
Type the Circuit ID number, then press
.
3
Type the ID numbers of all other devices listed in the system, pressing
after each entry.
Monitor
Performance
Event Log
Config
Inventory
Rlogon
Help
--------------------------
Product Information
----------------------------
Unit
: H2TU-C
H2TU-R
Product
: H2TU-C-319
H2TU-R-402
List
: 1
2
Sw Ver.
: 2.10
2.10
Build
# : 02
02
Checksum : 0x3FAE
0x3FAE
H2 Xcvr
: L1-RA2 1.31
L1-RA2 1.31
Serial # : 01232456789
0123456789
CLEI
: VACHDN0CAA
VARHJUUCAA
Mfg. Date: 11/05/99
11/05/99
--------------------
Circuit and Unit Identifications
---------------------
Circuit ID
:
xxxx--xxxx--xxxx--xxxx
H2TU-R ID
: yyyy--yyyy--yyyy--yyyy
Enter new ID and press <Enter> to set.
ID: xxxx--xxxx--xxxx--xxxx
04/21/00 12:30:01
H2TU-C
System: OK
I
ENTER
ENTER