152-319-100-02, Revision 02
Overview
H2TU-C-319 List 1 and List 1C
April 21, 2000
3
Figure 1.
HDSL2 System Model
H
I
G
AIN
S
OLITAIRE
R
EGENERATORS
For applications without regenerators (doublers), the H2TU-C-319 is directly connected to an H2TU-R remote
unit by one HDSL2 cable pair. The H2TU-C-319 List 1 and List 1C are compatible with all HiGain Solitaire
H2TU-Rs.
For regenerator applications, one to two regenerators may be used in the HDSL2 loop between the H2TU-C and
H2TU-R.
•
The H2TU-C-319 List 1 and List 1C can power one regenerator (H2RU-407 or H2RU-409) and a remote unit
(H2TU-R-402) for a total of two spans.
•
If the H2TU-R is locally powered, the H2TU-C can power up to two regenerators for a total of three spans.
Future enhancements of the H2TU-C-319 List 1 and List 1C will support regenerators.