The HMS-318 List 2B is VCCI certified and UL listed. Information on certification and warranty is shown below.

VCCI Certification

This equipment has been tested and found to comply with the limits for VCCI Class A Requirements. These limits 
are designed to provide reasonable protection against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not 
installed and used in accordance with this instruction manual, may cause harmful interference to radio 
communication.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does 
cause harmful interference to radio or television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

UL Listing

The HMS-318 List 2B is listed with the Underwriter Laboratory. 

Use caution when installing or modifying telephone lines. Dangerous voltages may be present. Do not install 
telephone wiring during a lightning storm. Always disconnect telephone lines and power connections from wall 
outlets before servicing or disassembling this equipment.

All wiring external to the product should follow the provisions of the current edition of the National Electrical 
Code.

Warranty

PairGain Technologies, Incorporated warrants its products to be free of defective and faulty workmanship for a 
period of 60 months, under normal use, from the date of shipment. PairGain's obligation, under this warranty, is 
limited to replacing or repairing, at PairGain's option, any such product which is returned during the warranty 
period per PairGain's instructions and which product, in PairGain's sole opinion, is determined to be defective 
upon examination at our plant.

The transportation charges from the Buyer to PairGain will be prepaid by the Buyer. When the equipment is 
shipped back to the Buyer, PairGain will pay the charges, unless no trouble is found (NTF), in which case the 
buyer will pay for the shipment.

PairGain may use reconditioned parts for such repair or replacement. This warranty does not apply to any product 
which has been repaired, worked upon, or altered by persons not authorized by PairGain or in PairGain's sole 
judgment has subjected to misuse, accident, fire or other casualty, or operation beyond its design range.

Repaired products have a 90-day warranty, or until the end of the original warranty period--whichever period is 
greater.

Modules sent to PairGain for repair will be repaired or replaced and returned to you as soon as possible. Normally, 
current products are repaired within 14 calendar days, and out-of-production products are repaired within 30 
calendar days. 

Summary of Contents for HiGain HMS-318 List 2B

Page 1: ...F PAIRGAIN TECHNOLOGIES INC ENGINEERING SERVICES TECHNICAL PRACTICE SECTION 150 318 122 01 Revision History of This Practice Revision 01 December 22 1997 A Initial Release Model List Number Part Numbe...

Page 2: ...n Technologies Inc Information contained in this document is company private to PairGain Technologies Inc and shall not be modified used copied reproduced or disclosed in whole or in part without the...

Page 3: ...____________________________________ 5 Site Requirements 5 Shelf Installation 5 Signal and Pin Assignments_____________________________________________________________ 6 Certification and Warranty____...

Page 4: ...Revision 01 December 22 1997 150 318 122 01 iv PairGain Engineering Plant Series HMS 318 List 2B...

Page 5: ...s Figure 1 houses a maximum of 22 HLU 319 line units and one HMU 319 management unit is 16 3 cm high x 30 5 cm deep x 44 2 cm wide exclusive of mounting brackets is equipped with brackets for mounting...

Page 6: ...ns are provided for connecting to the DSX 1 and HDSL spans Figure 2 and Figure 3 Figure 2 HMS 318 List 2B Connector Locations Figure 3 HMS 318 List 2B HLU Wire Wrap Pins Table 1 lists the connectors a...

Page 7: ...all cards in the shelf Use 50 pin mating female connectors AMP Kit No 2 22913 1 for 24 26 AWG Table 1 HMS 318 Connectors Identifier Connector Type Definition P1 Amphenol 50 pin Male DSX 1 Receive P2...

Page 8: ...e 4 HMS 318 List 2B Line Unit Pinouts Management Asynchronous Ports J24 and J25 are two RS 232 communication ports that allow two optional management systems to be connected to the HiGain system Consu...

Page 9: ...using one of the following methods Plug the DSX 1 interface cables into P1 and P2 and the HDSL interface cables into P3 and P4 Figure 2 on page 2 Span connections are listed in Tables 2 through 5 on...

Page 10: ...as described in the applicable practices SIGNAL AND PIN ASSIGNMENTS This section includes the following tables of signal and pin assignments Table 2 P1 DSX 1 Receive Tip and Ring on page 7 Table 3 P2...

Page 11: ...able Pin No Slot Card Pin No Cable Pin No Slot Card Pin No 26 1 B Tip 37 12 B 1 2 Ring 12 2 27 2 B 38 13 B 2 2 13 2 28 3 B 39 14 B 3 2 14 2 29 4 B 40 15 B 4 2 15 2 30 5 B 41 16 B 5 2 16 2 31 6 B 42 17...

Page 12: ...able Pin No Slot Card Pin No Cable Pin No Slot Card Pin No 26 1 A Tip 37 12 A 1 1 Ring 12 1 27 2 A 38 13 A 2 1 13 1 28 3 A 39 14 A 3 1 14 1 29 4 A 40 15 A 4 1 15 1 30 5 A 41 16 A 5 1 16 1 31 6 A 42 17...

Page 13: ...ble Pin No Slot Card Pin No Cable Pin No Slot Card Pin No 26 1 F Tip 37 12 F 1 6 Ring 12 6 27 2 F 38 13 F 2 6 13 6 28 3 F 39 14 F 3 6 14 6 29 4 F 40 15 F 4 6 15 6 30 5 F 41 16 F 5 6 16 6 31 6 F 42 17...

Page 14: ...able Pin No Slot Card Pin No Cable Pin No Slot Card Pin No 26 1 K Tip 37 12 K 1 9 Ring 12 9 27 2 K 38 13 K 2 9 13 9 28 3 K 39 14 K 3 9 14 9 29 4 K 40 15 K 4 9 15 9 30 5 K 41 16 K 5 9 16 9 31 6 K 42 17...

Page 15: ...d Pic Color Code Pair No Tip Ring 1 White Blue 2 Orange 3 Green 4 Brown 5 Slate 6 Red Blue 7 Orange 8 Green 9 Brown 10 Slate 11 Black Blue 12 Orange 13 Green 14 Brown 15 Slate 16 Yellow Blue 17 Orange...

Page 16: ...DTR Out The HMU 319 requires that DSR be asserted by the connected DCE for communications on this port The HMU 319 always asserts DTR on this port Table 8 J25 AUX Craft Port DTE Pin No Signal Directi...

Page 17: ...telephone wiring during a lightning storm Always disconnect telephone lines and power connections from wall outlets before servicing or disassembling this equipment All wiring external to the product...

Page 18: ...r write PairGain Customer Service to ask for a Return Material Authorization RMA number and any additional instructions Use the telephone or fax number listed below Telephone 800 370 9670 Fax 714 730...

Page 19: ...e Return Material Authorization Number you received from Customer Service clearly on the outside of the carton PairGain Technologies Inc 14352 Franklin Ave Tustin CA 92780 7013 Attention CRF RMA Numbe...

Page 20: ...Corporate Office 14402 Franklin Avenue Tustin CA 92780 Tel 714 832 9922 Fax 714 832 9924 For Technical Assistance 800 638 0031...

Reviews: