PairGain HiGain-2 HRU-612 Manual Download Page 2

Section 150-612-102
Revision 03

Page 2

A.  PRODUCT OVERVIEW

1.  DESCRIPTION AND FEATURES

1.01

PairGain’s HiGain-2 Remote Unit Model 
HRU-612, List 2, Figure 1, is the remote end

of a single pair repeaterless T1 transmission system.
It differs from the HRU-612, List 1 in the
implementation of the SAIS, DIS(abled) option and in
its ability to be locally powered.  When used in
conjunction with a HiGain-2 Line Unit HLU-611 the
system provides 1.544 Mb/s transmission on one
unconditioned copper pair over the cable ranges
shown in Table 1.  The HiGain-2 system utilizes
2B1Q VHDSL (Very High-bit-rate Digital Subscriber
Line) transmission technology.  HiGain-2 complies
with the ANSI T1E1.4, T1.403-1989 and T1E1.4/92-
002R2 technical standards & recommendations.  The
HRU-612 List 2 mounts in a single slot of any industry
standard 400 mechanics shelf or in equivalent
enclosures manufactured by PairGain Technologies.
The system also complies with TR-TSY-000063
(Network Equipment Building System (NEBS)
Generic Equipment requirements) and TR-TSY-
000499 (Transport System Generic Requirements -
TSGR) common requirements.

1.02

Revision History of this practice.

Revision 03 — January 30, 1996

a) Removed the local power and sealing

current options.

1.03

Features of the HRU-612 Issue 1 List 2
HiGain-2 Remote Unit are as follows:

• 

ANSI T1.403 DS1 Customer Interface

• 

VHDSL Line Powered operation - no local
power required

• 

Front Panel DS1 and VHDSL Status
Display

• 

Generic & addressable repeater Loopback
activation codes.

• 

Metallic smart-jack loopback.  Conforms to
TR-TSY-000312.

• 

Provisioning switches for CPE current,
RCV LBO and XMT LOS initiated loopback
or AIS.

• 

Front panel jacks for test access

• 

RS-232 front panel terminal access for
craft

• 

CPE current monitor test points

• 

Front panel VHDSL margin threshold
indicator.

• 

Lightning and power cross protection on
VHDSL and DS1 interfaces

• 

1568 kbps/s full-duplex 2B1Q VHDSL
Transmission on 1 pair

• 

DS0 blocking.

2.  APPLICATIONS

2.01

The primary application of the HiGain-2 
System is to provide a quick and cost-

effective way of delivering T1 High Capacity Digital
Service (HCDS) to customers over a metallic cable
pair.  The HiGain-2 system can be deployed on 1
unconditioned, non-loaded pair of wires without
repeaters, and without the need for either bridged tap
removal.

2.02

The general guidelines, on which the range 
deployment rules in Table 1 are based,

require that the VHDSL HiGain-2 loop, which
operates at twice the line rate of standard HiGain
HDSL products, have less than 35 dB of loss at the
2B1Q line rate of 392 kHz, @ 135 ohm source and
load impedances.

2.03

The HiGain-2 system operates with any 
number of other T1, POTS, Digital Data

Service (DDS) or other HiGain-2 Systems sharing the
same cable binder group.  HiGain-2 systems can be
used with customers requiring DS1 service on a
temporary or permanent basis.  HiGain-2 also
provides a means of quickly deploying service in
advance of fiber-optic transmission systems.  Using
HiGain-2 T1 service can be connected within a few
days or even a few hours.  Fiber optic systems can
be installed at a leisurely pace and cut-over from
HiGain-2 when the time allows.  The HiGain-2 system
can then be easily removed and utilized elsewhere.

Summary of Contents for HiGain-2 HRU-612

Page 1: ...IONS 2 3 SPECIFICATIONS 3 4 CERTIFICATION 3 5 WARRANTY 4 6 TECHNICAL ASSISTANCE 4 B FUNCTIONAL DESCRIPTION 7 FUNCTIONAL OPERATION 4 8 FRONT PANEL 6 9 OPTIONS 7 10 LOOPBACKS 9 C INSTALLATION AND TEST 1...

Page 2: ...smart jack loopback Conforms to TR TSY 000312 Provisioning switches for CPE current RCV LBO and XMT LOS initiated loopback or AIS Front panel jacks for test access RS 232 front panel terminal access f...

Page 3: ...50 Celsius 5 to 95 non condensing Mounting Single width 400 type mechanics slot Dimensions 5 6 H x 1 4 W x 5 6 D 4 CERTIFICATION 4 01 FCC Compliance The HRU 612 List 2 has been tested and found to co...

Page 4: ...Technical Assistance is available 24 hours a day 7 days a week by contacting PairGain s Customer Service Engineering group at one of the following numbers Telephone 800 638 0031 714 832 9922 Fax 714 8...

Page 5: ...the screen displays The port is configured as DCE with 8 data bits 1 stop bit and no parity Striking the SPACE bar several times invokes autobaud from 1200 to 9600 baud Note that if the RS 232 port in...

Page 6: ...B NET GREEN LED indicating the HRU is in a loopback state in which the signal from the NETwork is being looped back to the NETwork CI YELLOW LED indicating the HRU is in a loopback state in which the...

Page 7: ...611 100 for more details The HRU also has three user options set by switches located at the back of the unit as shown in Figure 4 Each switch has two settings as follows refer to the block diagram in...

Page 8: ...en the HRU does not function as the NID but is connected to an external NID It allows the external NID to set the appropriate NI level 15 Configures the T1 RCV LEVEL to 15 dB This sets the T1 output s...

Page 9: ...t jack loopback state It remains in this state until a loopdown command is detected or the default time out period if enabled expires 10 04 When the HRU is in its AIS ENA smart jack metallic loop back...

Page 10: ...ed or unframed The loop down command for both is the standard 3 in 5 five second pattern C INSTALLATION AND TEST 11 INSTALLATION 11 01 Upon receipt of the equipment visually inspect it for signs of da...

Page 11: ...e C O 7 To verify that the proper ports are use for the VHDSL DS1 pairs use an ohm meter to verify that the VHDSL HRU 612 port has a 180 k T to R resistive signature in contrast to the DS1 ports which...

Page 12: ...ustomer at HRU 612 NREM Network Remote Loopback DSX signal is looped back to DSX at HRU SMJK Remote Smartjack Loopback Signal from DSX is looped back at HRU by the HRU smartjack module TLOS Transmit L...

Page 13: ...ng System Settings review mode defined above FRM Frame SF ESF UNFR NONE Defines the type of frame pattern being received from the DSX 1 Displayed during System Settings mode defined above CODE Line Co...

Page 14: ...tiated by 2 in 5 in band loopback code or out of band ESF data link code See Figure 5 NREM Network Remote Loopback Loopback at HRU remote towards network initiated from C O network by intelligent line...

Page 15: ...Hour ES Errored Seconds The number of 1 second intervals that contained at least 1 CRC error This value is a running total of the last 24 Hours VHDSL 24 Hour UAS Unavailable Seconds The number of sec...

Page 16: ...Section 150 612 102 Revision 03 Page 16 Figure 7 HRU 612 Maintenance Terminal Main Menu Figure 8 HRU 612 View Span Status Display...

Page 17: ...Section 150 612 102 Revision 03 Page 17 Figure 9 HRU 612 System Settings Menu Figure 10 HRU 612 Set Clock Menu...

Page 18: ...Section 150 612 102 Revision 03 Page 18 Figure 11 HRU 612 View Performance Data Display Figure 12 HRU 612 View Performance History Display...

Page 19: ...2 102 Revision 03 Page 19 Figure 13 HRU 612 View Alarm History Display Copyright 1996 PairGain Technologies Inc PairGain is a registered trademark CopperOptics and HiGain are trademarks of PairGain Te...

Reviews: