Table 6.
Information Displayed in Main Console Screen
Field
Description
Circuit Configuration
G.703
Identifies the LTU and NTU G.703 ports.
n TS
Indicates the number of G.703 time slots (n) selected for the G.703
application interface.
V.35
Identifies the NTU V.35 port.
V.36
Identifies the NTU V.36 port.
RS-449
Identifies the NTU RS-449 port. (RS-530 supersedes RS-449, but
does not display on the main console screen. RS-449 must be
selected to use the RS-530 interface.)
X.21
Identifies the NTU X.21 port.
n k
Indicates the data rate selected for the Nx64K application interface.
RPF/WETTING
Indicates RPF or WETTING mode for Remote Power Feed. Nothing is
shown when NONE is selected.
Timing
No selection available.
G.703
Clock extracted from G.703 data stream.
CRC4 Mode
N/A
CAS Mode
Select the multiframe alignment mode for the G.703 interface.
INSERT
Inserts a multiframe alignment code into time slot 16 of frame 0 and
11011101 into time slot 16 of frames 1 through 15.
PASSTHRU
Time slot 16 is passed through unchanged at the G.703 port.
IDLE
Inserts the user-selected idle code into time slot 16 at the G.703 port.
Application Mode
Indicates application mode selected.
STRUCT
With framing.
UNSTRUCT
No framing.
PTM
System operates in the point-to-multipoint mode. Two pairs of a
single LTU connect to two different NTUs.
TSP
Time-slot prioritization with framing.
SINGLE