![PairGain 150-1260-24 Manual Download Page 25](http://html1.mh-extra.com/html/pairgain/150-1260-24/150-1260-24_manual_747320025.webp)
Revision 01
June 12, 1997
Section 150-441-124
HiGain HLU-D41
PairGain Engineering - Plant Series
Page 21
D. SETTING OPTIONS FROM THE MAINTENANCE TERMINAL
14. Using the Maintenance Terminal Menus
14.1
After you have connected the HLU-D41 to a dumb terminal, you must configure the dumb terminal
to the following communication settings.
•
1200 to 9600 baud (9600 baud is recommended)
•
Parity: None
•
8 data bits
•
1 stop bit
•
Hardware Flow Control set to None
•
VT Terminal Emulation
If using the Microsoft Windows terminal emulation program, from the Settings,
Terminal Preference menu, you must deselect
Show Scroll Bars and Use
Function, Arrow, and Ctrl Keys for Windows
14.2
Navigating the Maintenance Terminal menus.
Table 11 describes keys you can use on the
dumb terminal’s keyboard to navigate within the Maintenance Terminal menus.
Table 11. Dumb Terminal Navigational Keys
Key
Function
<U>
Updates a report
<C>
Clears a report
<S>
Selects the next Span Status screen
<P>
Selects the previous page of a report
<N>
Selects the next page of a report
<E>
Exits the current menu
<Esc>
Exits the current menu
14.3
Selecting an Option.
The Maintenance Terminal menus use two different means of selecting an
option:
Press the key indicated to the left of the selection.
Press the letter in parenthesis of the parameter to be changed.