9
Aqua-Mex
MA40-12E
ENGLISH
Product description
Aqua-Mex is a heat exchanger available in two versions: AM – a heat exchanger in standard configuration, and AM-FE - a heat
exchanger equipped with an electronic control unit and circulation pump for the primary circuit.
All Aqua-Mex variants can be ordered with an interior coil of either titanium or stainless acid-resistant steel.
The titanium version (T) is intended for use in aggressive water conditions, salt water and in pools with a chlorinator.
The Aqua-Mex heat exchanger features straight-through flow and 2” connections, contributing to high flow and lower energy
consumption.
Technical specifications
Fully equipped Aqua-Mex FE
Standard Aqua-Mex
A complete heat exchanger with electronic
control of temperature and flow.
It features an electronic flow switch
that shuts off the heat exchanger if
water flow stops.
A high-quality circulation pump
drives the primary circuit.
Capacity: 40 or 70kW.
The Aqua-Mex FE is protected from dust and water as per protection
class IP44, for installation either indoors our outdoors.
Aqua-Mex FE is CE-approved.
A complete heat exchanger with connections to the
primary and secondary water circuits.
Capacity: 40, 70 or 100kW.
Dimensions
L770xB140xH346 mm
Dimensions
40, 40T, 70, 70T
100, 100T
L770xB137xH178 mm
L942xB137xH178 mm
Weight
FE 40T 8,4 kg
FE 40 9,1 kg
FE 70T 8,8 kg
FE 70 9,7 kg
Weight
40T 4,4 kg
40 5,1 kg
70T 4,8 kg
70 5,7 kg
100T 5,3 kg
100 7,4 kg
Max primary circuit temperature
90ºC
Max primary circuit temp.
90ºC
Max secondary circuit temperature
45ºC
Max secondary circuit temp.
45ºC
Minimum flow, secondary circuit
90 litres/min
Min. flow, secondary circuit
90 litres/min
Pressure, primary circuit
0,3 - 6 bar
Pressure, primary circuit
max 6 bar
Pressure, secondary circuit
max 4 bar
Pressure, secondary circuit
max 4 bar
Connection, primary circuit
G1”
Connection, primary circuit
G1”
Connection, secondary circuit
2” (63 mm)
Connection, secondary circuit
2” (63 mm)
Ambient temp. during operation
+5 till +40 ºC
Protection class
IP44
Voltage
220-240V 1~N 50/60 Hz
Current rating
0,5 A
Power consumption
96 W
Performance, heat exchanger
Primary
Sekundary
D
T 60ºC *
Typ
l/min
m
3
/h
mvp
l/min
m
3
/h
H(m)
kW
40 FE40
20
1,2
0,6
250
15
0,4
40
40T
20
1,2
0,4
250
15
0,4
40
70
30
1,8
1,6
600
18
0,6
70
70T
30
1,8
1,4
600
18
0,6
70
100
40
2,4
2,6
333
20
0,8
100
100T
40
2,4
2,3
333
20
0,8
100
* The nominal heating output based on the temperature difference between incoming warm and cold medium (here 80-20=60°C).