background image

CAUTION:

PLEASE FOLLOW THIS INSTRUCTION MANUAL CAREFULLY TO

PREVENT ANY INJURIES OR COMPLICATIONS THAT MAY ARISE.

Before installing or maintaining the luminary, make sure all power is

WARNING:

.

TURNED OFF

Verify that supply voltage is correct by comparing it with the label information on all
fixtures.
Make all connections in accordance with the NEC requirements, and make sure all
luminaries are properly secured to prevent any wire complications. This luminary is
to always be installed with the lens facing down and it is not to exceed the
maximum ambient temperature rating noted on the specification sheet.

FPTA Series Post Top Light

Installation Guide

Need help? Tech help line:

(800) 988-6386

Email:

[email protected]

Website:

www.paclights.com

Copyright © 2019 PacLights

All Rights Reserved

Note: Instructions are subject to change at any time without notice

FPTA35, FPTA55, FPTA75

Includes:

02-00042-191212

Page 1 of 2

Connect the ACL and the ACN from the FPTA Fixture to the conduit with the AC Power Supply cords.  Follow the Wiring Diagram provided.

AC Power Supply

ROUND [

]

NEUTRAL [WHITE]

[BLACK]

INPUT

GRA

Y (-)

DIM

FPTA FIXTURE

VIOLET (+)

Tunable CCT (Correlated Color Temperature)

Turn over the FPTA Fixture showing the Fin side.  Remove the flush rubber inserts

(4) from the Cover Panel.  Remove the Screws (4) from the Cover Panel.  Lift the
cover from the FPTA Fixture. The Fixture is now open to adjust (if needed) the
Tunable CCT setting. The process is the same for all FPTA Fixtures.

1

The FPTA Fixture removed from the box is in a vertical configuration. The FPTA Fixture will be in the horizontal position.

2

The Tunable FPTA CCT Switch provides the user with

the three options available for the FPTA Luminaire.

4000K

5000K

3000K

400

0K

500

0K

300

0K

3

After setting the CCT SWITCH to the desired Kelvin temperature place the

Cover Seal properly back on the FPTA Fixture rim. Then, carefully place the Cover
on the FPTA Fixture.  Install the Screws (4) and then the Inserts.

INSERTS

SCREWS

FPTA

COVER

FPTA Initial Set-Up

Remove the Screws (2) and

Brackets (2) from each side.
Rotate the FPTA Fixture to the
horizontal position fin side up.
The Brackets can be discarded.

1

SHORT-CAP

INSERTS

SCREWS

COVER

SEAL

FPTA CCT

SWITCH

FPTA

DRIVER

FPTA

COVER

FPTA

FIXTURE

Place the Screws (4) included to

secure the Fixture in the horizontal
position.

2

SCREW

BRACKET

3

Set the Short-Cap on the NEMA

Receptacle correctly.  Install the
Short-Cap provided by pressing down
and twisting CW.

Note: If Photocell Sensor  is

provided see the following page for
instructions.

SCREW

The Tunable CCT Switch is a device that allows the user to choose a desired color
temperature 3000K, 4000K, or 5000K. The default factory setting is 4000K.

Note: If the Color temperature is acceptable and the Tunable CCT does not need to

be adjusted, the following steps can be skipped.

COVER

SEAL

INSIDE BACK-
BOX

3

7

1

2

3

4

5

6

4

3

Reviews: