CAUTION:
PLEASE FOLLOW THIS INSTRUCTION MANUAL CAREFULLY TO
PREVENT ANY INJURIES OR COMPLICATIONS THAT MAY ARISE.
Before installing or maintaining the luminary, make sure all power is
WARNING:
.
TURNED OFF
Verify that supply voltage is correct by comparing it with the label information on all
fixtures.
Make all connections in accordance with the NEC requirements, and make sure all
luminaries are properly secured to prevent any wire complications. This luminary is
to always be installed with the lens facing down and it is not to exceed the
maximum ambient temperature rating noted on the specification sheet.
FPTA Series Post Top Light
Installation Guide
Need help? Tech help line:
(800) 988-6386
Email:
Website:
www.paclights.com
Copyright © 2019 PacLights
All Rights Reserved
Note: Instructions are subject to change at any time without notice
FPTA35, FPTA55, FPTA75
Includes:
02-00042-191212
Page 1 of 2
Connect the ACL and the ACN from the FPTA Fixture to the conduit with the AC Power Supply cords. Follow the Wiring Diagram provided.
AC Power Supply
ROUND [
]
NEUTRAL [WHITE]
[BLACK]
INPUT
GRA
Y (-)
DIM
FPTA FIXTURE
VIOLET (+)
Tunable CCT (Correlated Color Temperature)
Turn over the FPTA Fixture showing the Fin side. Remove the flush rubber inserts
(4) from the Cover Panel. Remove the Screws (4) from the Cover Panel. Lift the
cover from the FPTA Fixture. The Fixture is now open to adjust (if needed) the
Tunable CCT setting. The process is the same for all FPTA Fixtures.
1
The FPTA Fixture removed from the box is in a vertical configuration. The FPTA Fixture will be in the horizontal position.
2
The Tunable FPTA CCT Switch provides the user with
the three options available for the FPTA Luminaire.
4000K
5000K
3000K
400
0K
500
0K
300
0K
3
After setting the CCT SWITCH to the desired Kelvin temperature place the
Cover Seal properly back on the FPTA Fixture rim. Then, carefully place the Cover
on the FPTA Fixture. Install the Screws (4) and then the Inserts.
INSERTS
SCREWS
FPTA
COVER
FPTA Initial Set-Up
Remove the Screws (2) and
Brackets (2) from each side.
Rotate the FPTA Fixture to the
horizontal position fin side up.
The Brackets can be discarded.
1
SHORT-CAP
INSERTS
SCREWS
COVER
SEAL
FPTA CCT
SWITCH
FPTA
DRIVER
FPTA
COVER
FPTA
FIXTURE
Place the Screws (4) included to
secure the Fixture in the horizontal
position.
2
SCREW
BRACKET
3
Set the Short-Cap on the NEMA
Receptacle correctly. Install the
Short-Cap provided by pressing down
and twisting CW.
Note: If Photocell Sensor is
provided see the following page for
instructions.
SCREW
The Tunable CCT Switch is a device that allows the user to choose a desired color
temperature 3000K, 4000K, or 5000K. The default factory setting is 4000K.
Note: If the Color temperature is acceptable and the Tunable CCT does not need to
be adjusted, the following steps can be skipped.
COVER
SEAL
INSIDE BACK-
BOX
3
7
1
2
3
4
5
6
4
3