background image

CAUTION:

PLEASE FOLLOW THIS INSTRUCTION MANUAL CAREFULLY TO

PREVENT ANY INJURIES OR COMPLICATIONS THAT MAY ARISE.

Before installing or maintaining the luminary, make sure all powers are

WARNING:

.

TURNED OFF

Verify that supply voltage is correct by comparing it with the label information on all
fixtures.
Make all connections in accordance with the NEC requirements, and make sure all
luminaries are properly secured to prevent any wire complications. This luminary is
to always be installed with the lens facing down and its not to exceed the maximum
ambient temperature rating noted on the specification sheet.

FFHS/2-400, FFHS/2-500, FFHS/2-600, FFHS/2-750,

Includes:

FFHS/2-1000, FFHS/2-1200

Need help? Tech help line:

(800) 988-6386

Email:

[email protected]

Website:

www.paclights.com

Copyright © 2021 PacLights

All Rights Reserved

STANDARD INSTALLATION STEPS

FFHS/2 J-Box

TO FIXTURE

ACN [

/WHITE]

BLUE

ACL [

/BLACK]

BROWN

G

GREEN

ROUND [

]

NEUTRAL [WHITE]

G

GREEN

ROUND [

]

HOT [BLACK]

INPUT

OUTPUT

DIM

Using a J-Box, Connect the ACL and the ACN from the J-Box to the Fixture with the AC Power Supply
cords.  Follow the Wiring Diagram provided.

02-00036-211214

Note: Instructions are subject to change at any time without notice

FF

F

HS/2 Series LED lood Light

Installation Sheet

Each FFHS/2 Luminaire includes a Trunnion Mount. The Trunnion Mount can be

adjusted to a desired tilt angle for all the FFHS/2 Series. The FFHS/2-600/750/1000
/1200 have a lever on each side along with larger side brackets to support the heavy
fixture.

FFHS/2-400/500

FFHS/2-600/750/1000/1200

FFHS/2-400/500 and FFHS/2-600/750/1000/1200 Luminaires have Trunnion

Mount bolt hole dimensions as seen below.  Please use the Trunnion Mount
dimensions below to determine the drilling template to follow if the fixture is going
to be surface mounted with the Trunnion Mount.

The FFHS/2 Luminaires can be adjusted by using a wrench to loosen the center

bolts and the arc slot bolts located on the sides of the FFHS/2 Luminaire. The
FFHS/2-600/750/1000/1200 Luminaires will also need the lever bolts located on the
sides of the FFHS/2 Luminaire to be loosened. The fixture will now be able to rotate
to the desired tilt/angle.  Replace the arc slot bolts and tighten all the other bolts.

0.62”

Ø0.62”

Ø0.64

FFHS/2-400/500

FFHS/2-600/750/1000/1200

6.50”

8.00”

0.64”

7.75”

9.50”

GRAY (-)

Violet (+)

GRAY (-)

Violet (+)

Surge Protector

Main Wire

Connector

DIM

AC Power Supply

Optional Dim Connector

ACL [BLACK]

ACN [WHITE]

G

GREEN

ROUND [

]

Center Bolt

Arc Slot Bolt

Lever Bolt

Center Bolt

Arc Slot Bolt

Lever Bolt

Lever

Page 1 of 2

Surge Protector

CAUTION:

PLEASE INCLUDE THE JUNCTION BOX PROVIDED.

Junction Box contains a necessary Surge Protector.

WARNING:

ACL [BLACK]

ACN [WHITE]

G

GREEN

ROUND [

]

Each FFHS/2 Series fixture is provided with a Junction Box that contains wire
Connectors and a Surge Protector. The Surge Protector is required! The Surge
Protector is pre-installed, fastened with a screw inside the Junction Box.  Please follow
the wiring diagram below.

Screw

Hole

Surge Protector

Connector

2

1

3

2

3

Reviews: