background image

CAUTION:

 

PLEASE FOLLOW THIS INSTRUCTION MANUAL CAREFULLY TO

PREVENT ANY INJURIES OR COMPLICATIONS THAT MAY ARISE.

WARNING: 

Before installing or maintaining the luminary, make sure all powers are

TURNED OFF

.

Verify that supply voltage is correct by comparing it with the label information on all
fixtures.
Make all connections in accordance with the NEC requirements, and make sure all
luminaries are properly secured to prevent any wire complications. This luminary is
to always be installed with the lens facing down and its not to exceed the maximum
ambient temperature rating noted on the specification sheet.
 

Includes: 

FCPG040, FCPG055, FCPG075, FCPG100 

 

FCPG Series LED Garage Light 

 Installation Sheet

Need help? Tech help line: 

(800) 988-6386

 Email: 

[email protected]

 Website: 

www.paclights.com

Copyright © 2017 PacLights 

All Rights Reserved 

 

(B) INSTALLATION STEPS FOR SURFACE MOUNT

 

The FCPG fixture has two cables attached to it.
The First cable consists of 3 coductors: ACL (black),
ACN (white), and a ground (green). These conductors
are to be connected to a 120v AC Power Supply Cable.

The second cable consists of two conductors: Dim+
(purple) and a Dim- (gray). These cables are used if the 
customer is installing a 0-10v dimmer to the FCPG
fixture. The dimmer is optional, please consult with a
Sales representative for more information.

* LED DRIVER Input Ground (green) wire only available for selected fixtures.

If the Ground Wire is missing and the Power Supply includes a ground wire, connect the power supply ground wire to the fixture.

02-00030-022318-1

 Note: Instructions are subject to change at any time without notice

CAUTION:

 

PLEASE FOLLOW THIS INSTRUCTION MANUAL CAREFULLY TO

PREVENT ANY INJURIES OR COMPLICATIONS THAT MAY ARISE.

WARNING: 

Before installing or maintaining the luminary, make sure all powers are

TURNED OFF

.

Verify that supply voltage is correct by comparing it with the label information on all
fixtures.
Make all connections in accordance with the NEC requirements, and make sure all
luminaries are properly secured to prevent any wire complications. This luminary is
to always be installed with the lens facing down and its not to exceed the maximum
ambient temperature rating noted on the specification sheet.
 

Includes: 

F2SB048,

 

F2SB080,

 

F2SB100,

 

F2SB150,

 

F2SB200,

 

F2SB300 

 

F2SB Series LED Area Light 

Installation Sheet

0200015-170815-1

Need help? Tech help line: 

(800) 988-6386

 Email: 

[email protected]

 Website: 

www.paclights.com

Copyright © 2017 PacLights 

All Rights Reserved    Note: Instructions are subject to change at any time without notice

 

(F2SB048)

STANDARD INSTALLATION STEPS

 

MOUNTING METHODS:

Please select the installation instructions based on proper mounting method:

SKU 

           Description 

 

 

AC2SBF 

        Slipfitter Mount  for 2 3/8 inch  OD  (2” Pipe

                          Bracket) Tenon (0º to 90º Vertical Aiming Angle)
AC2SBTM         Trunnion Mount
AC2SBAM1       6” Arm Mount for Square Pole
AC2SBAM2       6” Arm Mount for Round Pole

LED DRIVER

V(-)

[BLACK]

V(+)

[RED]

TO LOAD

[LED BOARD]

[WHITE]

[BLACK]

ACN [BLUE/WHITE]

ACL [BROWN/BLACK]

GROUND [GREEN]

NEUTRAL [WHITE]

GROUND [GREEN]

HOT [BLACK]

INPUT

OUTPUT

DIM

WHITE (-)

BL

UE(+)

Inside Junction Box

(Not Included)

PRE-CONNECTED

(DO NOT DISCONNECT)

1.    Connect the ACL and the ACN from the driver to the conduit with the AC Power Supply cords.Follow the Wiring Diagram provided.

* LED DRIVER Input Ground (green) wire only available for selected fixtures.

If the Ground Wire is missing and the Power Supply includes a ground wire, connect the power supply ground wire to the fixture.

(FOR DIMMABLE VERSION)

AC2SBF

AC2SBAM1

AC2SBAM2

AC2SBTM

TROUBLESHOOTING

1) Make sure the Power Outlet matches the Voltage on the driver. It is very
important for the Power Outlet and the driver to match. If these values do not match,
this can cause the LED fixture to not turn on or damage the driver. 

2) Check the LED Driver Input Connections. Make sure the ACL on the driver is
connected to the hot power outlet cable and the ACN on the driver is connected to the
Neutral wire on the power outlet.

3) Check the LED Driver Output Connections. These connections will already come 
installed when the fixture is purchased. However, if the Input Connections are double-
checked and the lumen is not turning on. It might be a good idea to make sure there are
no cuts in the wires and everything is properly connected.        
 

Please select the installation instructions based on proper mounting method:

SKU 

           Description 

 

 

AC2SBPS             Photocell,Twist Lock, 1.5 FC, 120-277 vAC, Instant On, 2-5 sec
                              OFF Delay
AC2SBPS480       Photocell,Twist Lock, 1.5 FC, 480 vAC, Instant On, 2-5 sec
                              OFF Delay
AC2SBSU             Surge Protector. VMAX AC: 277v, maximum Lightning Surge
                              Current: 20,000A
AC2SBSU480       Surge Protector. VMAX AC: 277v, maximum Lightning Surge
                              Current: 20,000A

OPTIONAL ADDONS

3a. Open the canopy light and use the Wiring
Diagram at the bottom of the page in order
to connect the LED Driver to the Power
Supply Cables that are inside the conduit.
All connections must be compliant with
NEC standards and must be
performed by a certified electrician.

1. Using an allen wrench, remove
the two socket head machine
screws in order to access the LED
driver inside the luminaire.

2. Using a slotted screw driver, remove the top
3/4” conduit plug from the top side of the FCPG
fixture. (This is only if the conduit is directly
above the luminaire. If the conduit is coming
from one of the sides of the luminaire, the FCPG
canopy also has conduit plugs on each side of
the fixture.)

WIRING DIAGRAM

DRAFT

(A) INSTALLATION STEPS WITH CONDUIT

 

4a. Once all the wires are properly
connected, close the FCPG luminaire
and fasten the two socket head 
machines screws back to lock the cap
in place.

5a. Add waterproof sealant on any
possible opening that will allow fluids
to enter the back box.

3b. Once you open the back box from
the garage light, you will notice there
are filled in slots which can be used as
a guide to drill holes (depending on the
Junction Box being used, drill holes on
the necessary slots).

4b. The FCPG luminaire also comes
with a foam felt pad to prevent any
liquids from entering the fixture. Place
the felt pad in between the fixutre and
the mounting surface. 

5b. Mount the Back Box to the ceiling using
mounting screws (not included). The number
and size of the mounting screws must be
calculated by a certified personnel and may
vary depending on the mounting surface and
junction box being used.

6. After all steps are properly followed, the
FCPG fixture is ready to be turned on. At this
point, provide power to the fixture. 

Reviews: