21/78
06/02/2008
1.00
Placing the agitator on closed tanks
Remark
The agitator blades and the motor are delivered separately.
The agitator motor has a built-in watercoupling for the automatic cleaning system.
If the free area above the tank in the dairy is insufficient, then put the agitator blade(s) inside the milk
vessel before placing the tank inside.
How to place it
Take the following steps to place the agitator – see also the drawing below:
Step
Action
1
Apply 1 layer of Teflon (PTFT-tape) to the threaded piece of the agitator motor shaft and check
that the O-ring is present.
2
Mount the 4 threaded rods to the motor flange. These rods must be screwed into the motor flange
until they are just coming through it.
3
Put the paddle in the tank via the manhole.
4
Put the paddle through the opening.
5
Put the rubber seal, the intermediary SS flange and the V-ring over the paddle shaft.
6
Screw the agitator motor to the agitator paddle.
7
Fit the motor on the mounting flange of the milk cooling tank. Take into account that the water
inlet is facing the water supply pipe of the cleaning system.
8
Fix the motor to the flange with the supplied 4 hex nuts and spring washers.
9
Check the positioning of the V-seal