AFX SERIES® OPERATION MANUAL
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 159 of 485
The soft keys on the PROGRAM MEMORY screen provide access to additional functionality
as listed in the table below.
SOFT KEY
Description
Browse(SK1)
Allows browsing for a particular register’s content.
Recall (SK2)
Recalls selected Register setup content
Save (SK3)
Saves setup to selected Register
Set (SK4)
Sets output to selected Register content
Refresh (SK5)
Return to previous screen
Table 6-24: Available SLEW RATE SETTINGS screen soft keys
6.7.5
CSC CONFIGURATION Screen
The CSC CONFIGURATION menu allows the Continuous Self Calibration mode to be
enabled. This feature is used to improve load regulation of the power source by continuous
measurement of the output phase voltage(s) and adjusting the internal set points as needed
to maintain close to zero load regulation. If the CSC is unable to get the output to the set
point, an error will be generated. This error can be disabled by unchecking the “Fault on
saturation” check box.
Figure 6-22: CSC CONFIGURATION screen
The soft keys on the CSC CONFIGURATION screen are listed in the table below
SOFT KEY
Description
-
-
-
-
Back (SK5)
Return to previous screen
Table 6-25: Available CSC CONFIGURATION screen soft keys
Summary of Contents for AFX Series
Page 484: ......