AFX SERIES® OPERATION MANUAL
SECTION 6: FRONT PANEL OPERATION
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 99 of 274
NORMAL EXECUTION MODE
Transient execution is controlled from the TRANSIENT PROGRAM screen. If no transient data
has been entered, no run mode soft key will be visible. In that case, you must use the
“Create” soft key to create a new transient sequence table.
The TRANSIENT PROGRAM screen is shown below.
There are three user settable parameters that control execution of the transient sequence.
They are:
1.
Run from step #
2.
Run to step #
3.
Repeat times
Transients will be executed when the “Run” soft key (SK1) is pressed. If the output if
OFF
however, a message will appear indicating the output must be turned
ON
first.
The transient execution will start at the step # set and run until the Run to step value is
reached. In the example above, from step #1 through step #6 inclusive.
The “Repeat times” field determines how many times the same sequence will be repeated.
To run a sequence indefinitely or until manually stopped, use the shuttle to scroll down to
zero or enter zero in this field using the keypad. This will set the repeat field to
“indefinitely”.
The following soft keys are available on the TRANSIENT PROGRAM screen.
SOFT KEY
Description
Run (SK1)
Starts the transient from the “Run from step#” row number
Edit (SK2)
Displays the TRANSIENT VIEW edit mode screen. See section 6.6.2
Debug (SK3)
Displays the TRANSIENT VIEW debug mode screen.
Stop (SK4)
Only appears if “Repeat time” value is set to “indefinitely”. Press to
stop execution manually
Table 6-14: Available TRANSIENT PROGRAM screen soft keys
Summary of Contents for 3120AFX
Page 273: ......