4
Technical Specifications
Technical specifications shown here apply at an ambient temperature of 25° C ± 5° C.
4.1
Single Chassis Models
Three and Two (split) Phase Mode
MODEL
No.
Rated
Voltage Range Current / Phs
Voltage Range
Curr./Output
No.
Outputs
Power
AC
DC
Chassis
360AFX
3 Phase
6 kW
300 V rms
16.7 A rms
425 Vdc
8.3 Adc
1
390AFX
3 Phase
9 kW
300 V rms
25.0 A rms
425 Vdc
12.9 Adc
1
3120AFX
3 Phase
12 kW
300 V rms
33.3 A rms
425 Vdc
16.7 Adc
1
3150AFX
3 Phase
15 kW
300 V rms
41.7 A rms
425 Vdc
21.0 Adc
1
Single Phase Mode
MODEL
No.
Rated
Voltage Range Current / Phs
Voltage Range
Curr./Output
No.
Outputs
Power
AC
DC
Chassis
360AFX
1 Phase
6 kW
300 V rms
50.0 A rms
425 Vdc
25.0 Adc
1
390AFX
1 Phase
9 kW
300 V rms
75.0 A rms
425 Vdc
37.9 Adc
1
3120AFX
1 Phase
12 kW
300 V rms
100.0 A rms
425 Vdc
50.0 Adc
1
3150AFX
1 Phase
15 kW
300 V rms
125.0 A rms
425 Vdc
63.0 Adc
1
4.2
Multiple Chassis Models
Multi chassis model configurations consist of a single master unit and one or more slave
units connected through a high speed parallel bus. Each unit requires its own three phase
AC input and must be turned on at the front panel using its individual circuit breaker. This
avoids massive inrush current at power up of the system as each unit can be turned on one
at a time. Multi chassis systems are installed in a suitable 19” cabinet from the factory with
a common AC input terminal block and a single phase or three phase common output
terminal block.
Three and Two (split) Phase Mode
MODEL
No.
Rated
Voltage Range Current / Phs
Voltage Range
Curr./Output
No.
Outputs
Power
AC
DC
Chassis
3180AFX
3 Phase
18 kW
300 V rms
50.0 A rms
425 Vdc
25.0 Adc
2
3240AFX
3 Phase
24 kW
300 V rms
66.7 A rms
425 Vdc
33.3 Adc
2
3300AFX
3 Phase
30 kW
300 V rms
83.3 A rms
425 Vdc
41.8 Adc
2
3450AFX
3 Phase
45 kW
300 V rms
125.0 A rms
425 Vdc
63.0 Adc
3
3600AFX
3 Phase
60 kW
300 V rms
166.7 A rms
425 Vdc
83.3 Adc
4
Single Phase Mode
MODEL
No.
Rated
Voltage Range Current / Phs
Voltage Range
Curr./Output
No.
Outputs
Power
AC
DC
Chassis
3180AFX
1 Phase
18 kW
300 V rms
150 A rms
425 Vdc
75.0 Adc
2
3240AFX
1 Phase
24 kW
300 V rms
200 A rms
425 Vdc
100.0 Adc
2
3300AFX
1 Phase
30 kW
300 V rms
250 A rms
425 Vdc
125.0 Adc
2
3450AFX
1 Phase
45 kW
300 V rms
375 A rms
425 Vdc
189.0 Adc
3
3600AFX
1 Phase
60 kW
300 V rms
500 A rms
425 Vdc
250.0 Adc