AFX SERIES® OPERATION MANUAL
SECTION 8: REMOTE PROGRAMMING
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 200 of 274
8.9
System Commands
Systems commands control system level functions or return model and revision information
on the connected unit. The following system commands are supported.
Query Format
SYSTem:ERRor[:NEXT]?
Description
This command returns next available error message from the error
queue. If no more error messages are available, returns 0,”NO ERROR”
result. Available error messages are:.
Returned Data Format
ERROR
Description
-0, "No error"
No error detected
-100,"Command error"
indicates invalid command or query
received
-102,"Command error: Syntax
error.”
Incorrect command syntax
-200,"Execution error"
indicates can't execute command
with parameters received
-222,"Command error: Data
out of range.'
Data exceeds available parameter
range
-300,"Device-specific error"
indicates UPC not properly
configured
-400,"Query error"
indicates query aborted
Query Example
SYST:ERR?
-102,"Command error: Syntax error.”
Query Format
SYSTem:ERRor:ALL?
Description
Returns all available error messages as a of error numbers and clears
the error message queue.
Returned Data Format
<nr1>,<nr1>,…..<nr1>
Query Example
SYST:ERR:ALL?
-222,-201,0
SYSTem:ERRor:ALL:NOCLEAR?
Description
Returns all available error messages as a single unterminated string but
does not clear
the error message queue.
Returned Data Format
<nr1>,<nr1>,…..<nr1>
Query Example
SYST:ERR:ALL:NOCLEAR?
-108,-108,-102
Command Syntax
SYSTem:ERRor:ALL:CLEAR
Description
This command clears the error message queue.
Parameters
None
Parameter Format
n/a
Example
SYST:ERR:ALL:CLEAR
Summary of Contents for 3120AFX
Page 273: ......