AFX SERIES® OPERATION MANUAL
SECTION 8: REMOTE PROGRAMMING
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 138 of 274
8.3
Calibration Commands
Calibration commands allow for fully automated calibration of the power source.
Note:
It is not recommended for the end user to use these command unless calibration
must be automated. Any errors in using these commands could invalidate user
calibration data. Pacific Power Source recommends the use of a competent and
authorized calibration lab to perform routine calibration.
The following calibration commands are supported. Commands marked “UPC” are provided
for backward compatibility with UPC controller based PPS power sources.
Command Syntax
CALibrate:COEFFicients:OFFSET:VOLTage
Description
Calibrates output DC voltage offset to lowest possible level.
Parameters
None
Parameter Format
n/a
Example
CAL:OFFSET:VOLT
Command Syntax
CALibrate:COEFFicients:OFFSET:CURRent
Description
Calibrates output DC current offset to lowest possible level
Parameters
None
Parameter Format
n/a
Example
CAL:OFFSET:CURR
Command Syntax
CALibrate:COEFFicients:NOISE:VOLTage
Description
Calibrates output voltage noise to lowest possible level.
Parameters
None
Parameter Format
n/a
Example
n/a
Command Syntax
CALibrate:COEFFicients:NOISE:CURRent
Description
Calibrates output current noise to lowest possible level.
Parameters
None
Parameter Format
n/a
Example
n/a
Command Syntax
CALibrate:COEFFicients:GAIN:VOLTage[:AC] <cr>
Description
Loads values measured with an external DVM for calibration of AC
voltage output and metering.
The first 3 values are Voltages measured at the output relay of the
power source for each phase.
The second set of 3 values are Voltages measured at the external
voltage sense points (at the load) for each phase.
Parameters
External reference voltage readings for each phase
Parameter Format
n/a
Example
n/a
Summary of Contents for 3120AFX