![Pacific Power Source 105LMX Operation Manual Download Page 212](http://html.mh-extra.com/html/pacific-power-source/105lmx/105lmx_operation-manual_746366212.webp)
LMX SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 212 of 463
Command Syntax
MEASure:KWHour:RESET
Description
This command resets all energy measurements to zero and resets the
time counter.
Parameters
None
Parameter Format
n/a
Example
MEAS:KWH:RESET
Query Format
MEASure:KWHour:ETIMe?
Description
This command returns the accumulated energy measurement time in
seconds.
Returned Data Format
<nr2>
Query Example
MEAS:KWH:ETIM?
120.5
Command Syntax
MEASure:KWHour[:STATe] <b>
Description
This command enables or disables the KHh measerments. When
enabled, the energy time counter starts till reset with the
MEASure:KWHour:RESET command.
Parameters
< 1 | ON | 0 | OFF >
Parameter Format
<b>
Example
MEAS:KWH ON
Query Format
MEASure:KWHour[:STATe]?
Description
The query format of this command returns the setting of the KWh
measurement as either 1 (ON) or 0 (OFF).
Returned Data Format
<nr1>
Query Example
MEAS:KWH?
1
8.4.6
Other Measurement Commands
Query Format
MEASure:TEMPerature:AMBient?
Description
Returns the ambient temperature of the power source in degrees
celcius.
Returned Data Format
<nr1>
Query Example
MEAS:TEMP:AMB?
24