LMX SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 205 of 463
8.3
Calibration Commands
Calibration commands allow for fully automated calibration of the power source.
Note:
It is not recommended for the end user to use these command unless calibration
must be automated. Any errors in using these commands could invalidate user
calibration data. Pacific Power Source recommends the use of a competent and
authorized calibration lab to perform routine calibration.
The following calibration commands are supported. Commands marked “UPC” are provided
for backward compatibility with UPC controller based PPS power sources.
8.3.1
LMX Calibration Commands
Command Syntax
CALibrate:COEFFicients:OFFSET:VOLTage
Description
Calibrates output DC voltage offset to lowest possible level.
Parameters
None
Parameter Format
n/a
Example
CAL:OFFSET:VOLT
Command Syntax
CALibrate:COEFFicients:OFFSET:CURRent
Description
Calibrates output DC current offset to lowest possible level
Parameters
None
Parameter Format
n/a
Example
CAL:OFFSET:CURR
Command Syntax
CALibrate:COEFFicients:NOISE:VOLTage
Description
Calibrates output voltage noise to lowest possible level.
Parameters
None
Parameter Format
n/a
Example
n/a
Command Syntax
CALibrate:COEFFicients:NOISE:CURRent
Description
Calibrates output current noise to lowest possible level.
Parameters
None
Parameter Format
n/a
Example
n/a