Understanding & Operating Your Pacific Energy Stove

The Pacific Energy SUMMIT woodstove is a culmi-
nation of years of research and development.  De-
signed  to  be  efficient,  clean-burning  and  user-
friendly,  this  heater  will  give  you  years  of  warm
service.  However, a knowledgeable operator is still
the most important factor for maximum perform-
ance  and  part  of  this  is  understanding  the  basic
functions of this design.

Traditional  wood  stoves  had  a  basic  combustion
system which allowed a considerable amount of heat
energy  to  escape  up
the  chimney  as
unburned  gases  and
particulates (smoke).
Pacific Energy has de-
signed  a  system  that
solves the problem by
burning  the  smoke
and releasing the ad-
ditional  heat  to  the
room.

This system has two
critical  design  fea-
tures:

1.

Above fire second-

ary air injection:
The hollow "air baf-
fle"  injects  super-
heated secondary air
just  above  the  load.
With the stove at the proper operating temperature,
this will create a secondary flame that will be evident
for approximately 1/3 of the total burn time.

2.

High mass and thermal insulation:

The high mass (weight) acts as a heat storage and the
thermal insulation keeps the combustion zone hot.

Active flaming takes place during the first part of the
burn.  During this stage, heat is stored in the mass of
the unit and is later released slowly and evenly.  As
wood  chars,  active  flaming  will  diminish.    This
clean charcoal burning stage will last for a consider-
able length of time and refuelling should be avoided
until the charcoal base has become quite small.

OPERATING TIPS

1. Always use dry, seasoned firewood, up to 18"

long.    Load  wood
endwise,  a  mixture
of  large  and  small
pieces,  on  top  of  a
good  ash  base  (1"
minimum).

2.  Operate on a me-
dium to high setting,
for up to 1 hour from
cold start.  After the
initial  warm  up  pe-
riod, refuel and leave
the  air  control  on  a
medium setting for 5
to 10 minutes more
and  then  set  the  air
control to the desired
position.

3.  If a slow burn is
desired,  set  the  air

control to low.  Active secondary burning should be
present above the wood load.  If it is not present or
goes out shortly after, proper operating temperature
has not been reached and the stove needs additional
warm up time.

For  additional  operating,  safety  and  maintenance
information refer to the installation manual.

1

2

3

5

6

4

1 -Boost Air

4 -Secondary Combustion Zone

2 -Main Combustion Air

5 -Radiant Heat

3 -Air Wash System

6 -Convected Heat

Reviews: