background image

4  

040515-24

©PACIFIC ENERGY FIREPLACE 
PRODUCTS LTD.

CAUTION: 

 Never use gasoline, gasoline type lantern fuel, 

kerosene, charcoal lighter fl uid or similar liquids to start or 
"freshen up" a fi re in this heater.  Keep all such liquids well 
away from the heater while it is in use.

CAUTION:  Hot while in operation.  Keep children, cloth-
ing and furniture away.  Contact may cause skin burns.

Your PACIFIC ENERGY heater is designed for many years of 
trouble free operation. Over fi ring the appliance will shorten 
the life of the product. Failure to recitify an over fi ring condition 
can be hazardous and may void the manufacturer's warranty.

Wood Selection

This heater is designed to burn natural wood only. Higher ef-
fi ciency and lower emissions generally result when burning 
air-dried seasoned hardwoods, as compared to softwoods 
or to green or freshly cut hardwoods.

Wood should be properly air dried (seasoned) for six months 
or more. Wet or undried wood will cause the fi re to smoulder 
and produce large amounts of smoke and creosote. Wet 
wood also produces very little heat and tends to go out often.

DO NOT BURN :

 

 

-Salt water wood  * 

 

-Treated wood

 

 

-Wet or green wood   

 

-Coal/charcoal

 

 

-Garbage* 

  -Solvents

 

-Lawn clippings/yard waste 

-Unseasoned wood

 

-Railroad ties 

 

-Manure or animal remains

 

-Materials containing rubber, including tires

 

-Materials containing plastic

 

-Waste petroleum products, paints or paint 

 

thinners, or asphalt products

 

-Materials containing asbestos

 

-Construction or demolition debris

 

-Paper products, cardboard, plywood, or particleboard.

*  These materials contain chlorides which will rapidly 
destroy metal surfaces and void warranty.

Burning these materials may result in the release of toxic 
fumes or render the heater ineffective and cause smoke.

The prohibition against burning these materials does not 
prohibit the use of fi re starters made from paper, cardboard, 
saw dust, wax and similar substances for the purpose of 
starting a fi re in an affected wood heater. 
Do not burn anything but wood.  Other fuels, eg. charcoal, 
can produce large amounts of carbon monoxide, a tasteless, 
odourless gas that can kill.  Under no circumstances should 
you attempt to barbecue in this heater.

How to Test Your Wood

Add a large piece of wood to the stove when it has a good 
large bed of coals.  It is dry if it is burning on more than one 
side within one minute.  It is damp if it turns black and lights 
within three minutes.  If it sizzles, hisses and blackens without 
igniting in fi ve minutes it is soaked and should not be burnt

Lighting a Fire

WARNING: Never use chemicals or any other volatile 
liquid to start a fi re.

1.  Adjust air control to “High” position(all the way to the left) 

and open door.

2.  Place crumpled newspaper in the centre of the heater 

and criss-cross with several pieces of dry kindling.  Add 
a few small pieces of dry wood on top.

3.  Ignite the paper and leave the door ajar approimately 

1/2"(13mm) - 1"(25mm) until the wood kindling is fully 
engulfed in fl ame.

4.  After the kindling is fully engulfed add a few small logs.  

Close door.

5.  Begin normal operation after a good coal base exists and 

wood has charred.

Curing of the Paint Finish

When burning your stove for the fi rst 2-3 times it is very im-
portant that the room be well ventilated.  Open all windows 
and doors.  Smoke and fumes caused by the curing process 
may cause discomfort to some individuals.

Normal Operation

WARNING:  This wood heater has a manufacturer-set 
minimum low burn rate that must not be altered. It is 
against federal regulations to alter this setting or other-
wise operate this wood heater in a manner inconsistent 
with the operating instructions in this manual.

1.  Set air control to a desired setting.  If smoke pours down 

across the glass (waterfall effect) this indicates you have 
shut the control down too soon or you are using too low a 
setting.  The wide range control makes fi nding the desired 
setting for your application easy.  As every home's heat-
ing needs vary (ie. insulation, windows, climate, etc.) the 
proper setting can only be found by trial and error and 
should be noted for future burns.

2.  To refuel, adjust air control to “High” position(all the way 

to the left), and give the fi re time to brighten.  Open the 
door slowly, this will prevent backpuffing or fl ame roll-out.

3.  Use wood of different shape, diameter and length ( recom-

mended 16"(406mm)).  Load your wood and try to place 
the logs so that the air can fl ow between them.  Always 
use dry wood.

4.  Do not load fuel to a height or in such a manner that would 

be hazardous when opening the door.

5.  For extended or overnight burns, unsplit logs are preferred.  

Remember to char the wood completely on "High" set-
ting before adjusting air control to the "Low" setting for 
overnight burn.

WARNING: Always keep loading door closed when burn-
ing. This heater is not designed for open door burning.

Operation

Summary of Contents for NEO 1.6 INSERT

Page 1: ...tructions Contact local building or fire officials about restrictions and installation inspection requirements in your area TESTED and LISTED to CAN ULC S627 AND UL 1482 Meets the Environmental Protection Agency s May 2015 Particulate Emission Standards IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER MODEL NEO 1 6 SERIES A SERIAL PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2014 ...

Page 2: ...als about restrictions and installation inspection requirements in you area Please read this entire manual before you install and use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Contents Safety 3 Chimney Smoke and Creosote Formation 3 Chimney Fires 3 In Case of a Chimney Fire 3 Avoiding a Chimney Fire 3 Operation 4 Wood Selection 4 ...

Page 3: ...ust be lived with Regular inspection and cleaning is the solution The use of dry seasoned wood and am ple combustion air will help to minimize annoying smoke emissions and creosote buildup Chimney Fires The result of excessive creosote buildup is a chimney fire Chimney fires are dangerous Chimney inside temperatures can exceed 2000 F 1100 C This causes much higher than normal temperatures in the c...

Page 4: ...re than one side within one minute It is damp if it turns black and lights within three minutes If it sizzles hisses and blackens without igniting in five minutes it is soaked and should not be burnt Lighting a Fire WARNING Never use chemicals or any other volatile liquid to start a fire 1 Adjust air control to High position all the way to the left and open door 2 Place crumpled newspaper in the c...

Page 5: ...r other stove lighting devices within the pedestal area Although this is possible it is not recommended NOTE Refer to local fire codes CAN B365 and NFPA 211 in the U S WARNING IFYOU CHOOSETO STOREWOOD BENEATH YOURUNIT EXERCISEEXTREMECAUTIONWHENLOAD ING THE WOODSTOVE EMBERS CAN FALL AND MAY IGNITE WOOD BENEATH STOVE WARNING No alteration or modification of the combus tion air control assembly is pe...

Page 6: ... from your dealer Use 16 1 2 419mm x 10 1 2 267mm x 5 mm Ceramic glass only Do not substitute with any other type To remove broken glass remove the door gasket and then undo the eight screws securing the gasket guides and glass retainers Remove all particles of glass Be careful as they are very sharp Install new glass complete with gasket Re place glass retainers and gasket guides then install new...

Page 7: ...Air riser tube in the back of the firebox Back side of airwash chamber located in the upper front of firebox Baffle locking pin Boost tube cover located in center of manifold bottom front of firebox When Cleaning the Chimney System Top baffle board blanket Baffle Brick Rails Manifold located in bottom front of firebox Blower The blower should be cleaned out a minimum every six months by using a va...

Page 8: ... 3 Usinga7 16 12mm wrench removelagboltsthatsecure hold down brackets to bottom pallet 4 Slide the hold down brackets away from the stove Side Panel Installation 1 Carefully remove the panels from the box 2 Engage the tabs in the panel into the slots in the panel mounting bracket Fig 1 3 Attachthepanel totherearshield Securewithtwoscrews Fig 2 FIG 1 SCREWS Assembly NOTE DIMENSION DOES NOT INCLUDE ...

Page 9: ...t To draw outside air from behind the stove an outside air adaptor may be required see Optional Blower section Cut or drill a 4 102mm hole through a wall behind the unit Use an appropriate household 4 102mm inlet Note This unit is not designed to be operated with the firing door open In addition to the obvious hazard of sparks landing on combustibles an open fire door will cause the heater to draw...

Page 10: ...ing codes The chimney flue size should be the same as the stove outlet for optimal performance Reduc ing or increasing the flue size may adversely affect stove performance Chimney flue exit is to be 3 feet 1 m above roof and two feet 0 6 m above highest projection within 10 feet 3 m The installation must meet all local codes Do not connect this unit to a chimney flue serving another appliance Mini...

Page 11: ...STED CONNECTOR AND CHIMNEY AND CHIMNEY Outside air supply must be used for Mobile Home installa tions see Figure 8 Page 13 Remove the chimney down to the roof flashing to allow for transportation of the mobile home FIG 6 Double Wall Connector Residential Single Wall Connector Residential Alcove Min Height 7 Max Depth 3 Double Wall Connector Mobile Home Clearances This heater must be installed with...

Page 12: ...n air in accordance with the clearances as stated on the label and in Figure 7 2 Mark the position for the hole in the ceiling and roof by using a string and plumb bob 3 Checkthattheintendedlocationwillnotinterferewithfloor joists ceiling joists or rafters before proceeding further 4 Cut a hole in the ceiling and roof to suit the chimney system and frame in the sides The chimney support is mounted...

Page 13: ...inimum 7 2 1m Ceiling Height Non combustible floor protector 48 1219 mm Hooded vent or 90 elbow turned down Ensure that the Masonry chimney meets all National Fire Protection Association and local building codes Have the chimney cleaned and inspected by a professional to ensure there are no cracks weak mortar or other signs of deterioration See pipe manufactuers installation instructions for furth...

Page 14: ...the fire has gone out and the unit cooled to below a useful heat output range Manual Tomanuallyoperatetheblower settherockerswitch to Man and set the speed control to desired setting This will bypass the sensing device and allow full control of the blower Switching from Auto to Man or selecting speed may be done anytime Optional Outside Air Adaptor The adaptor OAIR 1A is only required if outside c...

Page 15: ...ted check flue Provide outside air for combustion 4 Door gasket leakage Replace gasket Check latch Excessive Creosote Buildup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Stove Won t Burn 1 Combustion air supply blocked Check outside air supply for obstruction Check that room air cove...

Page 16: ...ment Baffle Kit NE16 BAFKIT 15 Baffle Pin SSER 125001 16 Ash System NE16 LGADA 17 Left Support Black NE16 78115 17b Right Support Black NE16 78125 18 Ash Dump Assembly NE16 7857 19 Ash Drawer NE16 78352 20 Air Shutter Assembly NE16 7826 21 Secondary Air Control Assembly NE16 7833 22 Trivet NE16 5037704 23 Levelling Feet 4pcs NE16 5049765 24 Lower Grill Assy NE16 5037703 25 Upper Grill NE16 5037702...

Page 17: ...erstanding the basic functions of this design Traditionalwoodstoveshadabasiccombustionsystemwhich allowed a considerable amount of heat energy to escape up the chimney as unburned gases and particulates smoke Pacific Energy has designed a system that solves the prob lem by burning the smoke and releasing the additional heat to the room Thissystemhastwocriticaldesign features 1 Above fire secondary...

Page 18: ... x 32 mm 5096 99 NEO 1 6 Firebrick Installation Instructions This package contains 13 full size firebricks as well as 2 various cut size bricks With the heater in the upright position install firebricks as follows Place 4 full size firebricks at the back of the heater first Next install the side firebricks 3 full size each side as shown below Lastly install 3 full size firebricks and bricks A B as...

Page 19: ...s operating correctly at installation Any part that shows in our judgment evidence of defect shall be repaired replaced or refunded at Pacific Energy s option The defective part may be required to be returned to Pacific Energy or an accredited agent transportation prepaid Porcelain is warranted for gloss retention Certain colors may darken when heated and return to the original shade when cool Gla...

Page 20: ...20 040515 24 PACIFIC ENERGY FIREPLACE PRODUCTS LTD ...

Page 21: ...040515 24 21 PACIFIC ENERGY FIREPLACE PRODUCTS LTD ...

Page 22: ...22 040515 24 PACIFIC ENERGY FIREPLACE PRODUCTS LTD ...

Page 23: ...ES INSTRUCTIONS D INSTALLATION ET D OPÉRATION FOURNI AVEC L APPAREIL CONTACTEZ LES OFFICIELS DE LA CONSTRUCTION OU DE SERVICE D INCENDIE POUR DES INFORMATIONS QUANT AUX RESTRICTIONS PERMIS D INSTALLATION ET INSPECTIONS DANS VOTRE RÉGION NE RELIEZ PAS CET APPAREIL À UN CONDUIT DE CHEMINÉE DESSERVANT DÉJÀ UN AUTRE APPAREIL ÉTATS UNIS SEULE MENT UTILISEZ UN RACCORDEMENT NOIR OU CLASSÉ DE 24 MSG ET AV...

Page 24: ...C ENERGY FIREPLACE PRODUCTS LTD PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan B C V9L 6V8 For technical support please contact your retailer Web site http www pacificenergy net Printed in Canada ...

Reviews: