Exit program, cancel call
25
Keypad beep
0= disable (default)
1=enable
Save program
26
Door beep
0= disable
1= enable (default)
00
Change master code (0000
is default)
27
Talk time (060-240
second). Default=60
second
01
Add new forwarding
tenant’s directory
28
Unlock relay1 time
(12-99 second).
Default= 12 second
02
Edit existing tenant’s
directory
29
Unlock relay2 time
(12-99 second).
Default= 12 second
03
Delete existing tenant’s
directory
30
Call Forwarding
0= disable 1= enable
04
Clear all forwarding
tenant’s directory
31
Call forwarding time
05-60 second
05
Call Forwarding
32
Forwarding directory
0-9
06
New access code
33
Temporary code
07
Delete access code
34
Special code
08
Clear all access code
35
Temporary card
09
Access code digit (4-8
digit). Default is 4-digit
36
Special card
10
Add new card
37
Initiate premise call
0=**, 1=## (default)
11
Delete card
38
System acknowledge
(0-9). Default= 3
12
Clear all card
39
Remote access
0= disable
1=enable (default)
13
Set time
40
DTMF relay 1 (1-9).
Default=9
14
Set date
41
DTMF relay 2 (1-9).
Default=8
15
Initializing event recording
42
Relay 2 Mode
1= door control (default)
2= relay 2 trigger
simultaneously as relay 1
3= enable if function code
24 is enable
4= turn relay 2 on and off
On=7, Off=6
16
AUS= auto unlock schedule
(0-9 schedule)
43
DND: do not disturb
time zone (0-9)
17
TMZ= time zone. 20 TMZ,
00-20.
44
Disable Time zone relay
1, 2 or both
18
HLD= holiday zone. 20
HLD, 1-20
45
Relay 1 and 2 unlock
timer
20
AUXIN1
0= disable (default)
1= enable control by relay 1
open interval
2= relay 1 control by AUXIN1
46
Firmware version
21
AUXIN2
0= disable (default)
1= enable control by relay 2
open interval
2= relay 2 control by AUXIN2
48
PBX enable. Default=
disable
22
Do not disturb
0= disable (default), 1=
enable
23
Lock-out Count
49
Edit Access code
24
Alarm
0= disable
1= local beep for 60 seconds
2= disable system for 60
seconds with no beep
3= call directory (0-9)
50
Erase the memory to
factory default
51
Welcome screen
Log on to programming:
Press
and
simultaneously then release,
the welcome message will stop
scrolling (repeat if screen still scrolls)
enter 4-
digit “
MASTER CODE
” (0000
is default), the screen will show:
Select the “
Function Code
” from the
table
OPERATION
Opening the door remotely
press
(relay 1) or
(relay 2)
Opening the door with the access code
press
(display screen
will stop scrolling) then press a valid 4-digit access code.
Extending talk time
tenant must press
from the phone after the
time out warning beep.
Calling into the system from premise location (Intercom)
1. Press
or
depending on function code 37, then
press
to communicate with the person
Calling into the system from remote location
:
Enable function code 39
1. Call the system phone number, hear one beep if the system
answering the call.
2. Press
then 4-digit master code, hear one short beep
3. Press
to establish two way communication
4. Press
or
to release the door.
Call waiting:
function code 38 must be set 1-9 and function code 39
can be set either 1 or 0, press
on your phone to transfer between
calls
See Function Code 37
Premise
Relay 1
Relay 2
Open cycle
##9/**9
##5/**9
Open hold
##8/**8
##4/**4
Close
##7/**7
##3/**3
OPERATION
TO CALL FROM THE SYSTEM
1. INTERCOM MODE PRESS
2. CALL FORWARDING MODE, press
to scroll name from A-Z or
to scroll name from Z-A then press
to call name selected.
Opening the door remotely
press
(relay 1) or
(relay 2)
QUANTUM Q5VOIP SERIES
PACH AND COMPANY INC.
QUICK GUIDE
Summary of Contents for QUANTUM Q5VOIP
Page 3: ......