background image

 

 

 
 
 
 
 

Operation Manual for the  

TT-65 Heater Assembly (Assembly With Sensor) 

PACE PART NUMBER 6010-0082-P1 

MANUAL NUMBER 5050-0297 Rev. G

 

 
IMPORTANT NOTICE

 - Two different heater assemblies on your handpiece TT-65. The enclosed heater contains five 

(5) wires and is installed in the half of the handpiece where the power cord enters the handle. If you have obtained the 
wrong replacement heater then you must obtain PACE Part Number 6010-0083 before preceding any further. 
Follow the procedure listed below to obtain optimum results. 

1. Disconnect the TT-65 handpiece from the power receptacle of the system power source. 

2. Remove the two (2) Gripper Mounting Screws on the Handle W/Sensor side of the handpiece (side with the Power 

Cable entering at the rear). Set Gripper (with or without cushions) and screws aside. 

3. Separate the two handpiece handles. The wiring of the defective heater is now exposed. The wiring of the heater w/o 

sensor remains hidden. 

4. Remove the two (2) Heater Mounting Screws.  

5. Carefully disconnect the five (5) heater leads from the Power Cable leads. Remove the defective heater from the 

handpiece. 

6. Carefully plug the five (5) color-coded leads of the replacement heater into the Power Cable leads as shown. Note that the 

ground wire (Green colored or Bare) is the only wire that can be observed. 
a) Plug the Bare (non-insulated) heater lead into the Green Power Cable lead 
b) Plug the two Blue heater leads (copper colored ends) into the Blue and the Orange Power Cable leads. 
c) Plug the two Tan sensor leads (silver colored ends) into the Yellow and the Red Power Cable leads. 

 
7. Mount the replacement heater to the handle using the two (2) Heater Mounting Screws removed in step 4. 
 
 
 
 
 

NOTE  

The tab of the heater flange must fit into the notch 

located on the outside edge of the handle. 

    8. Insure 

that the heater and Power Cable leads are dressed along the inside 

edges of 

the handle and 

not over 

the two 

mounting shoulders in the 

handle 

center. 

9. 

Carefully mate the two handpiece halves back together. 

      10. Install the Gripper and two (2) Gripper Mounting Screws removed in step 2. 

      11. Check the ends of both heaters to insure proper alignment with each other. If the end of one heater extends beyond the 

     other, loosen the Hinge Screw. Move the handles back and forth to align ends of heaters. 

 
 
 
 
 
 
 
 

NOTE  

Placement of the heater ends against a flat work 

surface with the handpiece held in a vertical position is 

recommended to ease alignment.

 

12. Tighten 

Hinge Screw to secure in position. Recheck the alignment. 

13. 

Connect the handpiece to the system power source. 

14. The handpiece is now ready for normal operation.

 

Reviews: