©2016 PACE Inc., Vass, North Carolina,
All Rights Reserved
Page
13
L) Initial Centering Nest
Adjustment – This can
be used to extend the
camera arm and
component tray for re-
aligning the component
nest without having to
run a profile.
M) Abort Process – Stops
any action the machine
is performing and goes
back to the home
position.
N) Heater Arm Steps
Down – This controls
the position the heater
head will descend to
before initiating auto or
manual placement
protocols.
O) Nozzle Tuning Settings
– The settings here
control how many
“steps” the heater head
will move when the
respective button is
pushed during manual
positioning.
P) Password Reset – The items in this section are used to reset or change the developer password. If the
current password is forgotten, you will need to contact PACE for a temporary access code.
Q) Manage – This section of the setup screen hosts several shortcuts directly to the folders containing the
information stored by the TF software. The default locations for these folders are;
•
"C:/Pace/Profiles" – Where profiles are stored as .dat file along with an .pdf showing an image
of the developer’s Profiler Screen.
•
"C:/Pace/LogFiles" – This folder has the logs containing time stamped .csv files from the
sensor, heater, and flow meter for profiles ran with the Log Data box checked on the Profile
Screen.
•
"C:/Pace/Reports" – The .pdf reports created when “Save Production Run” is utilized from the
Profile Screen are stored here.
•
"C:/Pace/Images" -- This is the storehouse of .jpg images the developer has put in for
reference during profiles run in production mode.
•
"C:/Pace/Snapshots" -- This is the storehouse of .jpg images saved from profiles run in
production mode for later examination.