background image

SX-80

SX-80

SX-80

SX-80

SX-80

8

present at the tip.

6) Return the handpiece to the cubby or resume work as required.

Replacing the Disposable Flux/Sodr Trap

As the Sodr-X-Tractor is used, solder and flux build-up will begin to impede the
airflow and decrease system performance.  The SX-80 utilizes a disposable chamber
which makes maintenance of the SX-80 a quick and simple process.  Regular
replacement of the Sodr-Flux Trap will keep the Sodr-X-Tractor operating at peak
performance.  To replace the Sodr-Flux Trap follow the procedures outlined below.

1) While holding the Sodr-X-Tractor with the tip facing away from you and the

handpiece in an downward
position, remove the door
assembly from the handpiece.
This action is accomplished by
pulling the plunger lock
approximately ¼” and turning it
approximately ten (10) degrees to
the right or left.  The door
assembly can now be removed by
simply gripping the door near the
ear shaped protrusions and lifting
straight up.

2) Replace the disposable chamber by holding the door assembly in the palm of

your hand with the filter assembly facing up.  With your free hand use a fresh
solder chamber with the arrows facing away to push the spent chamber out of
the door assembly and into a waste receptacle.  The fresh chamber is now in
position and ready for reassembly.

CAUTION

The handpiece will not function properly if the chamber is inserted incorrectly.  The
directional arrows on the solder chamber must be pointed at the heater.

3) Complete the process by lowering the door into the handle assembly.  Insure that

the door is properly situated with the ears seated in their respective detents.
Now return the plunger assembly to its locked position by simply twisting the
plunger lock mechanism so that it returns to the channels in the handle assembly.

4) Insure that the door assembly is securely in place by attempting to lift the door

from the handle assembly.  It should now be held firmly in place.

5) Check all air hose fittings.  Actuate the vacuum and insure that proper vacuum is

Summary of Contents for Sodr-X-Tractor SX-80

Page 1: ...actor Handpiece Operation MaintenanceInstructions Operation MaintenanceInstructions Operation MaintenanceInstructions Operation MaintenanceInstructions Operation MaintenanceInstructions SX 80 SX 80 SX...

Page 2: ...C FLO D SODR MINI WAVE PACE SENSATEMP SNAP VAC SODRTEK SODR X TRACTOR THERMOFLO THERMOJET THERMOTWEEZ TOOLNET VISIFILTER 2000 PACE Incorporated Laurel MD All rights reserved Printed in the U S A For a...

Page 3: ...ilure to do so may cause burns to the operator equipment or work surfaces and may be a potential ignition source if combustible materials are nearby Always use this handpiece in a well ventilated area...

Page 4: ...will cause a deterioration of performance To set up your SX 80 air hose connection perform the following steps 1 Air Hose To Handpiece Connection a Attach one end of a 137cm 54 inch length of air hose...

Page 5: ...air fittings are supplied with each additional air handpiece a Disconnect the 137cm 54 inch length of air hose from the FLOW IN side of the VisiFilter assembly Insert the ribbed end of a male quick co...

Page 6: ...e basic types 1 Endura Desoldering Tips These tips are tinnable and provide enhanced thermal performance for thru hole desoldering on high mass boards 2 EnduraPik Tips ProvidessaferemovalofTQFP ThinQu...

Page 7: ...safest removal some components on extra heavy assemblies may require preheating or auxiliary heating Tip Cleaning During heavy continuous desoldering on boards with flux residues or other contaminati...

Page 8: ...ar the ear shaped protrusions and lifting straight up 2 Replace the disposable chamber by holding the door assembly in the palm of your hand with the filter assembly facing up With your free hand use...

Page 9: ...SX 80 SX 80 SX 80 SX 80 SX 80 9 Heater Replacement NOTE Confirm that the heater assembly of your handpiece is defective by referring to the Corrective Maintenance section of the manual...

Page 10: ...p Resistance should be less than 2 ohms If not Oxidation buildup in Heater Bore Clean Heater Bore using appropriate wire brush Defective Heater Replace Heater Handpiece Connector Plug Corrective Maint...

Page 11: ...t 1 Flux Sodr Trap 1309 0054 P100 1309 0054 P1000 2 Handle Assembly 6010 0115 P1 3 Door Assembly 1119 0141 P1 4 Heater Assembly 6010 0107 P1 5 Plunger Shaft 1261 0154 P1 6 Plunger Lock 1500 0063 P1 7...

Reviews:

Related manuals for Sodr-X-Tractor SX-80