Introduction 

 
Thank you for your purchase of the 
PACE

®

 PH 100 (120 VAC, 50/60 Hz) 

P/N 8007-0572 or PH 100E 
(230VAC, 50/60 Hz) P/N 8007-0573 
Low Profile Preheater. The PH 100 
is a high powered (1600W), non-
contact infrared heating system with 
an ergonomic, low-profile design 
which allows operators to safely pre-
heat PCB’s for fast, efficient 
soldering, rework or repair, even on 
the highest mass, thermally 
challenging, lead-free assemblies.  
 
To ensure the long-term reliable operation of your PH 100 Preheater, read this Quick-Start 
Guide carefully before use, and keep it handy to answer any questions that may arise. 
 

NOTE: You should download the Full Operations Manual available online at:  

www.paceworldwide.com/PH100-PH100E-manual 

 

Rear Connector Panel 

 
1. 

Main Power Switch: Turn on/off PH 100 

2. 

Fuse Socket: 6,3x32mm 15A use slow-blo fuse 
(120VAC), or 6,3x32mm 10A use slow-blo fuse 
(230VAC) 

3. 

USB Connector: Allows for software/firmware 
upgrades via USB 2.0 Flash Drive  

4. 

Top Sensor Thermocouple Connector: Plug-in K-
Type Thermocouple, and secure to 

top 

of PCB 

5. 

Bottom Sensor Thermocouple Connector: Plug-in K-
Type Thermocouple, and secure to 

bottom

 of PCB 

6. 

Power Cord Input: Connect power cord here 

 

Safety Instructions 

 

 

 
1. 

NEVER touch the display with a hot soldering iron or other hot tools.  

2. 

After unpacking the device wait one hour to allow any condensation built up during 
transport to dissipate. 
 

3. 

Do not expose the device to water or other moisture.  

4. 

The PH 100 Preheater must only be used indoors near to a suitable power source. Avoid 
using extension cords. When not in use, store unit in a clean, dry place. 

5. 

Place the PH 100 Preheater device on a solid, hard, dry, stable surface with good 
ventilation. Do not place the device on a damaged or heat-sensitive surface. Leave proper 
clearance around the device and air gap at bottom (min. 20 cm) for proper ventilation. 

6. 

WARNING: ALWAYS let the PCB cool down before touching it after heating. After Power 
Off, the device will take up to 30 minutes to cool down. Wait for the device to cool down 
before touching the glass-ceramic heating plate. Always turn off the system and verify it 
has cooled down before leaving it unattended. The heating plate is hot and may cause burn 
injuries. ALWAYS use heat-insulated gloves.  

7. 

The PH 100 MUST ONLY be used for preheating PCBs for soldering and rework 
operations.  

8. 

DO NOT use the device if the glass-ceramic heating plate is cracked, or otherwise 
damaged or broken.  

9. 

DO NOT place PCB’s (or anything else) directly onto the glass-ceramic heating plate.  

10.  ALWAYS mount the PCB to be preheated onto the PCB holder.  
11.  PH 100 Preheater MUST ONLY be used by trained personnel.  
12.  DO NOT use the device near flammable materials. DO NOT store flammable materials 

near the device. ALWAYS consult the MSDS (Material Safety Data Sheet) of nearby 
materials to check their flammability. 

13.  DO NOT attempt to modify or repair the device yourself. If a fault develops, contact us at 

[email protected] (USA) or [email protected] (Europe). The case is 
sealed by a hologram label. If this is damaged, the warranty is automatically voided.  

14.  ALWAYS check that the power cable is not damaged before every use.  
15.  PH 100 Preheater MUST ONLY be connected to a properly grounded (earthed) power 

supply of the proper voltage and frequency (PH 100 120VAC, 50/60 Hz; PH 100E 230VAC 
50/60 Hz). Always check that the ground (earth) is working correctly.  

16.  Minimum/Maximum ambient temperatures: Min = +5°C (41°F); Max = +40°C (104°F) 
17.  Humidity Limits: Up to 80% relative humidity at 31°C, which decreases linearly between 

31°C and 40°C, to a maximum of 50% relative humidity. Maximum operating altitude above 
sea-level 2000m (6562 ft.). 

18.  During soldering and rework processes, toxic/noxious fume emissions may be released. 

ALWAYS use Fume Extraction or exhaust ventilation as specified in the MSDS of the 
solder, flux and solvent materials being used. As with all soldering devices, particularly in 
industrial use, it may be necessary to measure the emissions, which should be done by an 
expert. 

19.  DO NOT place the magnetic PCB holder rails or magnetic feet on a hot surface as they 

may become demagnetized.  

20.  The power outlet MUST be easily reachable to cut off the power in case of emergency. The 

power can only be cut by unplugging the device from the power outlet or unplugging the 
cord from the unit. Even after you have turned off the device using the ON/OFF switch, it is 
still connected to live power. 

 

Set-Up and Quick-Start of Your PH 100

 

 
1. 

Unpack the PH 100 unit and place on a solid, hard, dry, stable surface. Leave proper 
clearance around the device (min. 20cm). Wait one hour to allow any condensation built up 
during transport to dissipate. 
 