Safety Precautions 

 

 

 

1.  NEVER touch the display with a hot soldering iron or other hot tools. 
2.  Wait one hour after unpacking the device to allow any condensation built up during transport to 

dissipate.  

3.  Do not expose the device to water or other moisture. 
4.  The PH 100 Preheater must only be used indoors near a suitable power source. Avoid using extension 

cords. When not in use, store unit in a clean, dry place. 

5.  Place the PH 100 Preheater device on a solid, hard, dry, stable surface with good ventilation. Do not 

place the device on damaged or heat-sensitive surfaces. Leave space around the device and 
underneath (min. 20 cm) for proper ventilation. 

6.  WARNING: ALWAYS let the PCB cool down before touching it after heating. After Power Off, the device 

will take up to 30 minutes to cool down. Wait for the device to cool down before touching the glass-
ceramic heating plate. Always turn off the system and verify it has cooled down before leaving it 
unattended. The heating plate is hot and may cause burn injuries. ALWAYS use heat-insulated gloves. 

7.  The PH 100 MUST ONLY be used for preheating PCBs for soldering and rework operations. 
8.  DO NOT use the device if the glass-ceramic heating plate is cracked, or otherwise damaged or broken. 
9. 

DO NOT place PCB’s (or anything else) directly onto the glass-ceramic heating plate. 

10.  ALWAYS mount the PCB to be preheated onto the PCB holder. 
11.  PH 100 Preheater should only be used by trained personnel. 
12.  DO NOT use the device near flammable materials. DO NOT store flammable materials near the device. 

ALWAYS consult the MSDS (Material Safety Data Sheet) of materials to check their flammability. 

13.  DO NOT attempt to modify or repair the device yourself. If a fault develops, contact us at 

[email protected]

 (USA) or 

[email protected]

 (Europe). The case is sealed by a 

hologram label. If this is damaged, the warranty is automatically voided. 

14.  ALWAYS check that the power cable is not damaged before every use. 
15.  PH 100 Preheater MUST ONLY be connected to a properly grounded (earthed) power supply of the 

proper voltage and frequency (PH 100 120VAC, 50/60 Hz; PH 100E 230VAC 50/60 Hz). Always check 
that the ground (earth) is working correctly. 

16.  Minimum/Maximum ambient temperatures: Min = +5°C (41°F); Max = +40°C (104°F) 
17.  Humidity Limits: Up to 80% relative humidity at 31°C, which decreases linearly between 31°C and 40°C, 

to a maximum of 50% relative humidity. Maximum operating altitude above sea-level 2000m (6562 ft.). 

18.  During soldering and rework processes, toxic/noxious fume emissions may be released. ALWAYS use 

Fume Extraction or exhaust ventilation as specified in the MSDS of the solder, flux and solvent materials 
being used. As with all soldering devices, particularly in industrial use, it may be necessary to measure 
the emissions, which should be done by an expert. 

19.  DO NOT place the magnetic PCB holder rails or magnetic feet on a hot surface as they may become 

demagnetized. 

20.  The power outlet MUST be easily reachable to cut off the power in case of emergency. The power can 

only be cut by unplugging the device from the power outlet or unplugging the cord from the unit. Even 
after you have turned off the device using the ON/OFF switch, it is still connected to live power. 

Summary of Contents for 8007-0572

Page 1: ... 1 PH 100 Low Profile IR Pre heater Operations Manual Manual Number 5050 0587 Rev C Applies to 8007 0572 PH 100 115 120VAC 50 60Hz 8007 0573 PH 100E 230VAC 50 60Hz With Program Version 2 4 ...

Page 2: ...ations 2 Safety Precautions 3 Board Holder Set up 4 Preheating Basics 4 System Operation 5 Main Menu 5 Icon Bar Explanations 6 Device Settings Menu 6 Heater Settings Menu 8 Preheat Cycles 9 Tips and Troubleshooting 10 Replacement Parts 10 PACE Worldwide Limited Warranty 10 Contact Information 11 ...

Page 3: ...sistive Touch Screen Control Panel 5 Ceramic Glass Heat Diffuser 1 Power Switch 2 Fuse Socket 6 3x32 mm 3 USB 2 0 Port 4 Top Sensor K type Thermocouple connector 5 Bottom Sensor K type Thermocouple connector 6 Power Cord Receptacle 1 2 3 4 1 2 3 6 5 4 Rear panel NOTE Use only Slo Blo fuses in this unit 15A for 120V units 10A for 230V units 5 ...

Page 4: ...umber Domestic 8007 0572 Export 8007 0573 Dimensions 3 in H w board holder no feet x 17 in W x 14 in D 76 2 mm x 381 mm x 457 2 mm Weight 18 05 lbs 8 2 kg Power Requirements 115 VAC Domestic 14 Amps 1600W 230 VAC Export 7 Amps 1600W Pre Heaters 4 x Ceramic Infrared IR Heaters in 2 zones Control Resistive Touchscreen PC Board Size 11 75 in 298 45 mm D x 11 75 in 298 45 W width is open ended when us...

Page 5: ...mable materials near the device ALWAYS consult the MSDS Material Safety Data Sheet of materials to check their flammability 13 DO NOT attempt to modify or repair the device yourself If a fault develops contact us at support paceworldwide com USA or sales paceworldwide com Europe The case is sealed by a hologram label If this is damaged the warranty is automatically voided 14 ALWAYS check that the ...

Page 6: ...have been included To prevent damage to the glass ceramic plate it is best to remove the aluminum board holder rails completely before adding the feet underneath the steel support rails Each foot is notched on one end for the steel support rails to set into and the bottom is magnetic with a Teflon pad to help prevent scratches The small feet give a clearance of 0 875 inches 22 25mm from the bottom...

Page 7: ...n use will display N C Not Connected 6 Icon Bar Displays key operational information icons during use See page 6 for icon explanations 7 Password Screen Lock Button Tap this button to lock the screen On the Icon Bar a lock appears Tap the button again and enter password to unlock 8 Device Settings Menu Button Tap this button to open main Device Settings Menu screen See page 8 for full explanations...

Page 8: ... active when this icon is displayed Indicates the Top Sensor is active This icon only shows up when the power limiter has been activated and designates the unit as currently operating at half its normal capacity 800 watts If this icon is not present the unit can make use of the entire 1600 watt capacity Finally if the screen is locked using the password feature a lock will appear in the icon bar a...

Page 9: ...n brings us to the following screen The color is changed using the RGB color model We can change the color of the button at idle the color when it s pressed as well as the color of the icon Tapping the plus or minus in each column adjusts the amount of red green or blue in that order for the chosen item The empty square in the lower right corner will display the resulting color Tapping the arrow r...

Page 10: ...e currenttly installed software version 11 Power Settings This square provides the same function as tapping the power meter on the Main Menu it provides access to the power limiting function Options are 1600 watts or 800 watts 12 Temperature Scale Tapping here will switch the PH 100 between Celsius and Fahrenheit Heater Settings Menu There are two heater settings menus selectable in the Device Set...

Page 11: ...a number pad for entering a time anywhere from 0 to 60 minutes After entering a time press the checkmark to exit and start the timer To change an incorrect number press the arrow button to backspace Continue pressing the arrow to clear any entries and exit without setting a timer After exiting the Preheat Time entry screen the timer begins and the unit will attempt to reach the temperature set in ...

Page 12: ...lown Use only Slo Blo fuses in this unit 15A for 120V units 10A for 230V units Replacement Parts 10A Time Lag Fuse for 230v 1159 0281 P3 15A Time Lag Fuse for 115v 1159 0282 P3 Thermal Fuse Harness 1159 0283 P1 PACE Worldwide Limited Warranty PACE warrants to the first user that products manufactured by it and supplied hereunder are free of defects in materials and workmanship for a period of one ...

Page 13: ...to PACE without a Service Authorization SA Number Any warranty or other claim with respect to the products must be made in writing delivered to PACE or local Authorized PACE distributor for Buyers outside the USA and the United Kingdom within a reasonable time of the expiration date of this warranty with sufficient evidence of purchase and date of receipt otherwise user s rights under this warrant...

Reviews: