PEC017
5/3/2018
Page
94
of
105
N087
Page
Min
Default
Max
Units
PTO Mode Preset Engine Speed (In-
Cab)
0
780
2000
RPM
Engine Speed Capture or Engine Speed Preset w/ Set Switch (N110)
must be PRESET (0)
N088
Page
Min
Default
Max
Units
Remote PTO in Vehicle Parked
State
OFF (0)
ON (1)
ON (1)
ON/OFF
N089
Page
Min
Default
Max
Units
Neutral Required for PTO Mode
OFF (0)
ON (1)
ON (1)
ON/OFF
* Recommended to be disabled with Eaton Ultrashift transmissions
N090
Page
Min
Default
Max
Units
Engine Speed Decrease
w/Res/Decel (Remote)
10
50
1000
RPM
N091
Page
Min
Default
Max
Units
Engine Speed Ramp-down
w/Res/Decel (Remote)
10
250
1000
RPM/SEC
N092
Page
Min
Default
Max
Units
Engine Speed Increase w/Set/Accel
(Remote)
10
50
1000
RPM
N093
Page
Min
Default
Max
Units
Engine Speed Ramp-Up w/Set/Accel
(Remote)
10
250
1000
RPM/SEC
N101
Page
Min
Default
Max
Units
Disable PTO Mode w/ Brake
Depressed
OFF (0)
ON (1)
ON (1)
ON/OFF
* Required for Mobile Cab Station w/ Accelerator and Switches configurations
* Required if
PTO Mode Vehicle Speed Limit (N080)
is greater than 3 MPH