background image

 

ATEX HYDROKINETIC ROTATING CLEANING HEADS 

SAFETY NOTE 

SN01 

Rev. 00 

Date 22/04/2020 

Pag. 4 of 10 

 
 

2.2

 

FIELD OF APPLICATION 

 
The head is designed to be used with water up to 90 °C, with addition of mild detergents or disinfectants. In case of 
use  with  special  or  even  flammable  liquids  (different  viscosity,  chemical  harshness  or  other),  please  contact  our 
technical  department.  The  head  shall  be  used  within  pressure,  temperature  and  RPM  speed  limits  reported  in  the 
official  documents,  such  as  declaration  of  conformity,  certificate  of  assembly  and  technical  data  reported  on  the 
instruction manual. 
 
The cleaning liquid shall have an ignition temperature of minimum 50  K over the maximum exterior temperature of 
the appliance’s surface where the cleaning liquid is utilized. 
 
The ambient temperature when the appliance is working shall range between  0 ÷ +90 °C. For a different use, please 
contact the manufacturer for a customized study. 
 
Only  when  it’s  used  according  to  the  prescriptions  included  in  this  manual  and  in  correctly  tackling  residual  risks 
raising from its use, does this head assure a level of protection high enough as to not generate potential sources of 
priming, when installed in a potentially explosive environment. 
 
The appliance in question grants that potential sources of priming are not activated in normal functioning and even in 
case of foreseeable and rare failure or malfunction.  
 
Breakage  or  failure  to  the  appliance  can  happen.  In  that  case,  it  is  necessary  to  check  the  causes  of  failure.  When 
these are traced down to the appliance, they must be removed.  
 
Note 1: the appliance reaches a maximum surface temperature according to the temperature of the fluid pumped in. 
The temperature class must take into account the safety factor 0,8 aimed for appliances of class 1, see table below. 
 

FLUID TEMPERATURE 

°C 

TEMPERATURE CLASS 

(GAS) 

MAX EXTERIOR SURFACE TEMPERATURE 

(DUSTS) 

0 to ≤ 68 

T6 

T85 °C 

> 68 to ≤ 80 

T5 

T100 °C 

> 80 to ≤ 90 

T4 

T135 °C 

 
Note 2: the cleaning liquid is to be chemically compatible with the seals that have been assembled by the manufacturer 
of the appliance. The marking will identify the material of the seals, as per the following chart: 
 

MARKING ON THE EQUIPMENT 

MATERIAL OF THE SEALS 

EPDM 

HNBR 

FFKM 

FKM 

 
Compatibility (category - zoning) between the head and the environment must be established by the user according to 
exact and specific considerations Directive 99/92/EC. 
 
It is not allowed to use the heads in potentially explosive atmospheres in underground and mining areas, EPL Ma and 
Mb (group I category M1 and M2). 
 
 

Summary of Contents for MI63-50

Page 1: ...2460 2460...

Page 2: ...2460...

Page 3: ...SAFETY NOTE SN01 Rev 00 Date 22 04 2020 Pag 1 of 10 DOCUMENT REVISION REV DATE MODIFICATION 00 22 04 2020 First issue PREPARED BY RGQ Michele QUATTRONE SIGNATURE CHECKED BY DUT Fabio PEDRONI SIGNATURE...

Page 4: ...USE WORKING 6 3 5 1 WORKING ADJUSTMENT 6 3 5 2 SUITABLE NON SUITABLE USE 7 3 5 3 DANGEROUS AREAS 7 3 5 4 DANGER POSSIBLE RISKS 7 3 5 5 PPE PERSONAL PROTECTIVE EQUIPMENT PROCEDURES TRAINING 8 3 6 SYST...

Page 5: ...subjected to a conformity test according to directive 2014 34 EU annex VIII requiring for a technical file to be sent to a Certification Body The marking of the cleaning head is 2460 II 1 G Ex h IIC T...

Page 6: ...hen installed in a potentially explosive environment The appliance in question grants that potential sources of priming are not activated in normal functioning and even in case of foreseeable and rare...

Page 7: ...ubject to shock impacts tumbles deteriorment and other damaging which could compromise the function of the head Any eventual damage must be immediately communicated to P A S p A for assessment 3 2 INS...

Page 8: ...ction grade minimum IP54 for Gas and IP6X for powders Insert the connection tubes entry and exit following a good technique and using acknowledged components adopting the foreseen clamping instruction...

Page 9: ...sidered in the planning stage in view of the safety measures adopted The Company P A S p A declines all responsibility for damage to persons animals or things derived by an improper use of the apparat...

Page 10: ...ted back pressure to the nozzles acts negatively on the head compromising the set calibration The nozzles must be exempt from back pressure They must not be blocked and no flow from the nozzles toward...

Page 11: ...certify that the operator is opportunely instructed to carry out all the safety procedures hygiene in the work areas according to the protocol in order to avoid any eventual risks deriving from the op...

Page 12: ...enance replacement the removal of the head from the application is permitted only when the apparatus is not under pressure and in the absence of a potential explosive atmosphere Before reusing or reut...

Page 13: ...in iniett 2mm 25 4600 24 MI63 45 test mot idrocin iniett 2mm 25 4600 30 MI63 50 test mot idrocin iniett 3mm 25 4600 40 MI63 50 test mot idrocin iniett 4mm 25 4600 50 MI63 50 test mot idrocin iniett 5m...

Page 14: ...elast E 20 inox 1 10 25 80 0207 52R Corona z 50 inox 1 1 26 10 3080 58R An OR 1 78x56 87 mm Vi 70 2 10 27 80 0219 51R Tappo EI M14x1 inox 3 3 28 10 3060 10R An OR 1 78x12 42 mm Vi 70 3 10 29 80 0221...

Page 15: ...ydr driv 2mm inject 25 4600 24 MI63 45 Tank cl hydr driv 2mm inject 25 4600 30 MI63 50 Tank cl hydr driv 3mm inject 25 4600 40 MI63 50 1 8 inject 4 00mm 25 4600 50 MI63 50 Tank cl hydr driv 5mm inject...

Page 16: ...1020 05R Snap ring E 20 Sst 1 10 25 80 0207 52R Ring gear z 50 Sst 1 1 26 10 3080 58R O ring 1 78x56 87 mm Vi 70 2 10 27 80 0219 51R Plug int hex M14x1 Sst 3 3 28 10 3060 10R O ring 1 78x12 42 mm Vi 7...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...P A S p A Via Milano 13 42048 Rubiera Reggio Emilia Italy Tel 39 0522 623611 Fax 39 0522 629600 info pa etl it www pa etl it COMPANY WITH QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001...

Reviews: