background image

 

ATEX HYDROKINETIC ROTATING CLEANING HEADS 

SAFETY NOTE 

SN01 

Rev. 00 

Date 22/04/2020 

Pag. 5 of 10 

 
 

2.3

 

TERMS USED 

 
Qualified/Specialised  Technician:  personnel  who was  trained  for installation,  adjustment, maintenance,  repair.  It  is 
required that the technician shall be trained and allowed to perform such tasks, and to have specific knowledge not 
only of the tool and the risks stemming from its use, but also the possible risks of the appliance in question. 
 
Temperature Class (T): it is the maximum superficial temperature of the appliance (taking into account also the safety 
coefficient as reported in UNI CEI EN ISO 80079-36:2016. It also corresponds to the max. surface temperature of the 
head. 
 

3.

 

INSTRUCTIONS FOR USE 

 

3.1

 

STORING, SHIPPING AND MOVING 

 
The  heads  are  supplied  with  adequate  packaging.  The  unloading  and  moving  of  the  tools  shall  be  carried  out  by 
trained personnel, who is also responsible for checking that the order and the freight match.  
 
It  is  necessary  to  carefully  move  the  head  to  avoid  shock impacts,  and  therefore,  possible deformations  and cracks 
which could successively determine leaking of the product contained through the attachment points of the head a/w 
possible trigger source (sparks, adiabatic compression, etc.). 
 
Localities  of  Warehouse  storage,  conservation,  transport  and movement of  the  heads must  guarantee  that  they  are 
not subject to shock impacts, tumbles, deteriorment and other damaging which could compromise the function of the 
head. 
 
Any eventual damage must be immediately communicated to P.A. S.p.A. for assessment. 
 

3.2

 

INSTALLATION 

 

3.2.1

 

WARNING 

 
Each installation or reinstallation must be performed by qualified personnel, duly trained and informed on the related 
risks, even concerning the instructions of this document. 
 
When  using  the  utensils  do  not  apply  excessive  force  rotation  on  the  connections  in  the  presence  of  a  potential 
explosive atmosphere. 
 
The  use  of  utensils  in  zone  0  and  20  is  not  permitted.  The  use  of  utensils  in  zone  1/21  and  2/22  is  allowed  with 
particular instructions under the directive UNI CEI EN ISO 80079-36:2016 which has to be known by the operator. 
 
Installation  errors  can  provoke  deformation  or  structural  collapse  of  the  pipe  connection,  also  a  loss  of  fluid  in  the 
ambient. 
Installation errors can compromise the regular movement with effective possibility of sparking. 
 

3.3

 

NOZZLE SELECTION 

 
The nozzles, in numbers of 2 or 4 of high pressure washing type with straight jet, must be appropriate to the flow & 
pressure in which they intend to operate (see nozzles chart) bearing in mind that the pressure spec. to consider in the 
choice  is  the  one  achieved  by  subtracting  from  the  pressure  value  in  the  pump,  the  value  of  the  pressure  loss 
determined  by  the  delivery line  and  head.  This last  value can  be  obtained from  the  diagram D3  of this  manual.  The 
nozzles must be made of material compatible with the directive 2014/34/EU and category 1. 

Summary of Contents for A42R-316-360

Page 1: ...la NSF CLEANING HEAD Stainless steel construction Suitable for utilization in food industry This is a self propelled tank cleaning head when the flow rate increases the head rotates faster Cleaning of interior surfaces of tanks and drums Reduced flow high pressure high cleaning impact Orbital coverage of interior surfaces Small spray turret that fits through reduced tank opening Rotating speed ind...

Page 2: ... 32 195 F 1 8 NPT ATTACCO ALIMENTAZIONE ACQUA INLET CONNECTION SIZE ATTACCO UGELLI 2 o 4 NOZZLES CONNECTION 2 OR 4 PESO WEIGHT SPECIFICHE TECNICHE PRESSIONE NOMINALE RATED PRESSURE PORTATA FLOW RATE PRESSIONE CONSENTITA PERMISSIBLE PRESSURE TEMPERATURA MASSIMA ACQUA MAX WORKING TEMPERATURE 40 140 bar 4 14 MPa 580 2000 psi TECHNICAL SPECIFICATIONS TEMPO PER UN CICLO COMPLETO DI LAVAGGIO 47 GIRI DEL...

Page 3: ... SAFETY NOTE SN01 Rev 00 Date 22 04 2020 Pag 1 of 10 DOCUMENT REVISION REV DATE MODIFICATION 00 22 04 2020 First issue PREPARED BY RGQ Michele QUATTRONE SIGNATURE CHECKED BY DUT Fabio PEDRONI SIGNATURE APPROVED BY AD Alberto BENETTI SIGNATURE ...

Page 4: ...5 USE WORKING 6 3 5 1 WORKING ADJUSTMENT 6 3 5 2 SUITABLE NON SUITABLE USE 7 3 5 3 DANGEROUS AREAS 7 3 5 4 DANGER POSSIBLE RISKS 7 3 5 5 PPE PERSONAL PROTECTIVE EQUIPMENT PROCEDURES TRAINING 8 3 6 SYSTEM PROCEDURES 9 3 6 1 TOOLS MACHINERY 9 3 6 2 LOAD UNLOAD 9 3 6 3 START STOP 9 3 7 INSPECTION ORDINARY EXTRAORDINARY MAINTENANCE SERVICE CLEANING 9 3 7 1 PRECAUTIONS 9 3 7 2 ORDINARY MAINTENANCE AND ...

Page 5: ... subjected to a conformity test according to directive 2014 34 EU annex VIII requiring for a technical file to be sent to a Certification Body The marking of the cleaning head is 2460 II 1 G Ex h IIC T6 T4 Ga II 1 D Ex h IIIC T85 C T135 C Da Ta 0 C 90 C Presafe 20 ATEX 319809 where Symbol 2460 DNV GL Presafe AS Certification Body Symbol CE Ex in accordance with directive 2014 34 EU Group II suitab...

Page 6: ...when installed in a potentially explosive environment The appliance in question grants that potential sources of priming are not activated in normal functioning and even in case of foreseeable and rare failure or malfunction Breakage or failure to the appliance can happen In that case it is necessary to check the causes of failure When these are traced down to the appliance they must be removed No...

Page 7: ...subject to shock impacts tumbles deteriorment and other damaging which could compromise the function of the head Any eventual damage must be immediately communicated to P A S p A for assessment 3 2 INSTALLATION 3 2 1 WARNING Each installation or reinstallation must be performed by qualified personnel duly trained and informed on the related risks even concerning the instructions of this document W...

Page 8: ...ection grade minimum IP54 for Gas and IP6X for powders Insert the connection tubes entry and exit following a good technique and using acknowledged components adopting the foreseen clamping instructions During the connection of the tubes make an electrical earth link up with a minimum cable size 4mm observing the prescribed terms for equipotential connections Inspection after installation to be ca...

Page 9: ...nsidered in the planning stage in view of the safety measures adopted The Company P A S p A declines all responsibility for damage to persons animals or things derived by an improper use of the apparatus a o the non observance of the dispositions contained in the present manual 3 5 3 DANGEROUS AREAS Particular attention has to be reserved to any area potentially explosive around the head and also ...

Page 10: ...ated back pressure to the nozzles acts negatively on the head compromising the set calibration The nozzles must be exempt from back pressure They must not be blocked and no flow from the nozzles towards the inside of the head is permitted Ambient risks Ambient conditions different than those specified can cause a danger source They can cause dangerous service conditions with relation to the proces...

Page 11: ... certify that the operator is opportunely instructed to carry out all the safety procedures hygiene in the work areas according to the protocol in order to avoid any eventual risks deriving from the operations mentioned above 3 7 2 ORDINARY MAINTENANCE AND CLEANING After a normal daily usage wash the inside of the head with clean water without any additives Carry out an internal check after 100 ho...

Page 12: ...tenance replacement the removal of the head from the application is permitted only when the apparatus is not under pressure and in the absence of a potential explosive atmosphere Before reusing or reutilizing the head after washes general maintenance or any other necessary operation follow the warnings as seen on paragraph 3 1 1 of this safety note After reinstalling the device and before placing ...

Page 13: ... 1 2 19 80 0859 60R Anello rasamento Ai316 1 3 20 80 0858 60R Perno M10 inox Ai316 1 1 21 80 0821 60R Satellite z 24 Ai316 9 3 22 80 0822 84R Boccola Di 8x12 mm 9 3 23 80 0833 21R Portasatelliti intermedio completo 2 1 24 80 0809 60R Corpo 3 stadi Ai316 1 1 25 80 0213 84R Perno rasamento plast 1 10 26 80 0832 21R Portasatelliti completo sp rasam 1 1 27 80 0808 60R Spina 3x24 5mm Ai316 1 3 28 16 19...

Page 14: ...59 60R Shim ring Sst Ai316 1 3 20 80 0858 60R Pin M10 Ai 316 Sst 1 1 21 80 0821 60R Planetary gear z 24 Ai316 9 3 22 80 0822 84R Bushing 8x12mm 9 3 23 80 0833 21R Plan gear holder 3 pins gear Sst 2 1 24 80 0809 60R Ring gear z 60 3 stage cleaner sst 1 1 25 80 0213 84R Shim pin plast 1 10 26 80 0832 21R Plan gear holder 3 pins Sst 1 pin 1 1 27 80 0808 60R Parallel pin 3x24 5mm Ai316 1 3 28 16 1909 ...

Page 15: ......

Page 16: ...P A S p A Via Milano 13 42048 Rubiera Reggio Emilia Italy Tel 39 0522 623611 Fax 39 0522 629600 info pa etl it www pa etl it COMPANY WITH QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001 ...

Reviews: