OPERATION
Operation via the local inputs
The inputs can be activated by shorting (or opening) the appropriate input terminal
to the input common terminal.
Input modes
The inputs are factory defaulted to toggle mode and can be changed via the web
interface of the dimmer or by TCP/IP commands. The input modes work as follows.
1. Toggle mode (factory default)
Each short button press toggles the corresponding output
2. Independent inputs
Inputs can be detached from their corresponding outputs, in which case they will
have no effect on them. However, the status changes of the digital inputs will still
be reported via the open TCP/IP sockets and on the Control page of the built-in
website. This can be used for monitoring the status of digital sensors connected to
the inputs or to activate lighting scenes or macros whenever the input gets
triggered.
3. Input follow mode
The status the outputs will follow the state of the corresponding input. The output
will be on while the momentary switch is pressed and off while it is released.
4. Monostable mode
The outputs can be programmed to turn on for an adjustable amount of time when
the corresponding input is triggered (e.g: staircase lighting).
5. Switch mode
This mode makes it possible to use maintained (standard light switches) instead
of momentary switches on the inputs. Each trigger of the switch (On or Off) will