background image

CHARGER SAFETY WARNINGS

DESCRIPTION OF SYMBOLS

2

SPECIFICATIONS

Input: 

 

200-250V AC 50-60Hz

Output: 

 

21V DC, 3A

Battery Charge Time: 

30Min - PXBP-150U (18V 1.5Ah)

 

 

40Min - PXBP-200U (18V 2.0Ah)

 

 

60Min - PXBP-300U (18V 3.0Ah)

 

 

75Min - PXBP-400U (18V 4.0Ah)

 

 

120Min - PXBP-520U (18V 5.2Ah)

 

 

100Min - PXUBP-520U (18V 5.2Ah Ultra)

1.   Charging Unit
2.  Charging Unit LED

ozito-diy.co.uk

1

FAST CHARGER

ORIGINAL INSTRUCTIONS

PXCG-030U

Art.-No.: 30.003.95 

I.-No.: 11018

Danger!

 Read the operating instructions to reduce the risk of inquiry.

Caution!

 

The charging unit is allowed to be used only 

for the lithium-ion batteries of the Power X Change range!

For use in dry rooms only.

Double Insulated (Safety Class II)

The reprinting or reproduction by any other means, in whole or in part, of documentation and papers 

accompanying products is permitted only with the express consent of the iSC GmbH.

Subject to technical changes

Danger!
The equipment and packaging material are not toys. Do not let children play 

with plastic bags, foils or small parts. There is a danger of swallowing or 

suffocating!

 ELECTRICAL SAFETY

WARNING!

 

When using mains-powered tools, basic safety precautions, including the 

following, should always be followed to reduce risk of fire, electric shock, personal injury 

and material damage. 

Read the whole manual carefully and make sure you know how to switch the tool off in an emergency, before operating 

the tool. 

Save these instructions supplied with this tool for future reference.
Before you connect the charger to the mains supply make sure that the data on the rating plate are identical to the mains 

data.

This tool charger is double insulated; therefore no earth wire is required.

If the supply cord is damaged, it must be replaced by an electrician or a power tool repairer in order to avoid a hazard.

Note:

 Double insulation does not take the place of normal safety precautions when operating this tool. The insulation 

system is for added protection against injury resulting from a possible electrical insulation failure within the tool.
The power supply for this products charger should be protected by a residual current device (rated at 30mA or less). A 

residual current device reduces the risk of electric shock.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, 

or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the 

appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.

Danger!

 Read all safety regulations and instructions.

 Any errors made in following the safety 

regulations and instructions may result in an electric shock, fire and/or serious injury.

Keep all safety regulations and instructions in a safe place for future use.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use 

of the appliance by a person responsible for their safety.
Replacing the power cable If the power cable for this equipment is damaged, it must be replaced by the manufacturer or 

OEM after-sales service or by similarly trained personnel to prevent hazards.

a) The charging unit is not allowed to be used for non-rechargeable, normal batteries.

b) Sufficient ventilation is required.

c) The current and voltage information on the battery pack must be the same as that on the charging unit.

d) Do not expose the charging unit to splashwater or rain.

e) The charging unit must be disconnected from the socket outlet before the rechargeable battery is inserted into or 

removed from the charging station.

f) Do not throw old or damaged batteries into water or fi re. Follow the environmental protection directives.

g) A defective or no longer chargeable battery must be treated as special waste. Dispose of it at a special collection point. 

Do not dispose of it with your normal household waste or throw it into water or fire.

h) Place the charging unit away from all sources of heat.

i) To reduce the risk of electric shock, pull the power plug out of the socket outlet by the plug itself and not by the cable 

when you want to disconnect the charging unit from the power supply.

j) Do not take the charging unit apart. Take it to an authorized repair center if servicing or repairs are needed. Incorrect 

assembly can result in an electric shock and even death or fi re.

k) Children must always be supervised in order to ensure that they do not play with the equipment.

DECLARATION OF CONFORMITY

 Yang/Product-Management

Weichselgartner/General-Manager

explains the following conformity according to EU directives and norms for 

the following product

Fast Charger PXCG-030U (Ozito)

   2014/29/EU 

 2005/32/EC_2009/125/EC 

X

 2014/35/EU 
 2006/28/EC 

X

 2014/30/EU 
 2014/32/EU 
 2014/53/EC 
 2014/68/EU 
 90/396/EC_2009/142/EC 
 89/686/EC_96/58/EC 

X

 2011/65/EU

   2006/42/EC

 Annex IV

Noti

 ed Body:

Noti

 ed Body No.:

Reg. No.:

 2000/14/EC_2005/88/EC

 Annex V

 Annex VI

 Noise: measured L

WA

 = dB (A); guaranteed L

WA

 = dB (A)

P =  KW; L/Ø =  cm

Noti

 ed Body:

 2012/46/EU

Emission No.:

Standard references: EN 60335-1; EN 60335-2-29; 

EN 62233; EN 55014-1; EN 55014-2; EN 61000-3-2; EN 61000-3-3

Landau/Isar, den 02.03.2018

First CE: 18  

 

Archive-File/Record:

 NAPR018733

Art.-No.:

 30.003.95 

I.-No.: 11018 

Documents registrar:

 Alex Kurz

Subject to change without notice

 

Wiesenweg 22, D-94405 Landau/Isar

 ISC GmbH · Eschenstraße 6 · D-94405 Landau/Isar

3000395_11018_PXCG-030U.indd   135

06.03.2018   14:18:51

Thermal cut out protection

Reviews: