background image

Version 1.4 rev 24 Apr 2019

9

IKon-M

SECTION 1: INTRODUCTION

This manual provides an overview of the iKon-M camera series. The iKon-M is available in different configurations to 
suit demanding applications such as Astronomy, Life Sciences, Electro- and Photoluminescence Inspection and high 
energy applications. This manual includes a description of the main features of the iKon-M, installation, routine operation 
and troubleshooting. It also provides a summary of some of the technical features of the iKon-M series. For further 
information on operation and control of the iKon-M refer to the relevant software guide e.g. Solis, and to the andor 
website for further technical information to help you get the best from your camera.

Figure 1: The iKon-M (934 model shown)

Summary of Contents for ANDOR iKon-M

Page 1: ...iKon M Hardware Guide andor com Andor Technology Ltd 2019 Covering models iKon M 912 iKon M 934 iKon M SO iKon M SY PV Inspector Version 1 4 rev 24 Apr 2019 ...

Page 2: ... SUPPLY UNIT 16 2 4 POWER REQUIREMENTS 16 SECTION 3 INSTALLATION 17 3 1 TRANSPORT AND STORAGE INFORMATION 17 3 2 C MOUNT 17 3 3 MOUNTING THE IKON M USING THE MOUNTING FLANGE 17 3 4 ATTACHING TO MOUNTING POSTS 17 3 5 CONNECTING THE IKON M TO THE PC 17 3 6 CONNECTING THE IKON M TO THE POWER SUPPLY 18 3 7 CONNECTING A COOLING SYSTEM 18 3 7 1 Important Considerations when using Liquid Cooling Systems ...

Page 3: ...n speed 22 SECTION 5 ADDITIONAL INFORMATION FOR SO AND SY MODELS 23 5 1 IKON M SO 23 5 1 1 Best Practice Guidelines 23 5 1 2 Removal of the Protective Plate 23 5 1 3 Mounting the Camera on the Vacuum Chamber Flange 25 5 2 IKON M SY 26 5 2 1 Best Practice Guidelines 26 SECTION 6 MAINTENANCE 27 6 1 REGULAR CHECKS 27 6 2 ANNUAL ELECTRICAL SAFETY CHECKS 27 6 3 GENERAL CLEANING DECONTAMINATION INFORMAT...

Page 4: ...on 1 4 rev 24 Apr 2019 4 IKon M APPENDIX A TECHNICAL SPECIFICATIONS 30 APPENDIX B MECHANICAL DRAWINGS 31 APPENDIX C DEWPOINT INFORMATION 34 APPENDIX D REFERENCE INFORMATION 35 APPENDIX E OTHER INFORMATION 36 ...

Page 5: ...power requirements Solis information removed this is available from Solis in built help 1 4 24 Apr 2019 Updated US and Japan addresses Updates to this Manual Changes are periodically made to the product and these will be incorporated into new editions of the manual Please check for new releases of the manual in MyAndor http my andor com login aspx If you find an issue in this manual please contact...

Page 6: ...t of the detachable power supply cord is required ensure replacement is of same type and rating 11 Performance of the system may be adversely affected by rapidly changing environmental conditions or operation outside of the operating conditions specified in TECHNICAL SPECIFICATIONS 12 While running an experiment try to keep temperature as stable as possible 13 This equipment has not been designed ...

Page 7: ...ks that may find their way to the mains electricity supply and create a hazard Refer to the information in SECTION 3 7 for general guidelines on the correct installation and use of a liquid cooling system 22 See SECTION 6 3 Cleaning and Decontamination 23 Do not expose the product to extreme hot or cold temperatures 24 Do not expose the product to open flames 25 Do not allow objects to fall on the...

Page 8: ... retain the packaging materials to transport or return equipment if required If the equipment appears damaged in any way return it to sales outlet in its original packaging No responsibility for damage arising from the use of non approved packaging will be accepted Ensure all items and accessories specified at the time of ordering and as detailed on the packing list are present if any items are mi...

Page 9: ...and high energy applications This manual includes a description of the main features of the iKon M installation routine operation and troubleshooting It also provides a summary of some of the technical features of the iKon M series For further information on operation and control of the iKon M refer to the relevant software guide e g Solis and to the andor website for further technical information...

Page 10: ... 7126 Fax 44 0 28 9031 0792 Andor Technology 300 Baker Avenue Suite 150 Concord MA 01742 USA Tel 1 860 290 9211 Fax 1 860 290 9566 Asia Pacific China Andor Technology Japan 5F IS Building 3 32 42 Higashi Shinagawa Tokyo 140 0002 Japan Tel 81 0 3 6732 8968 Fax 81 0 3 6732 8939 Andor Technology Unit 1 Building A 66 Zhufang Rd Haidian Dist Beijing 100085 China Tel 86 0 10 8271 9066 Fax 86 0 10 8271 9...

Page 11: ...MATION PROVIDED HEREIN 1 3 Copyright and Protective Notices The copyright in this document and the associated drawings are the property of Andor Technology Ltd and all rights are reserved This document and the associated drawings are issued on condition that they are not copied reprinted or reproduced nor their contents disclosed The publication of information in this documentation does not imply ...

Page 12: ...ents Description Quantity iKon M CCD Camera model as ordered refer to Specification sheet for full model information 1 Software CD Solis and SDK are ordered separately Hardware Guide in electronic format 1 Performance Booklet 1 BNC SMB Cable 1 USB 2 0 Cable 1 ...

Page 13: ...del Open fronted High Energy model 200 μm Beryllium foil window High Energy model 1 5 2 Optional Accessories A range of accessories is available see table below The iKon M is intended only for use with accessories supplied and recommended by Andor Please contact your local Andor representative if further information is required Description Code iKon M 912 iKon M 934 PV Inspector iKon M SO iKon M S...

Page 14: ...or s unique UltraVacTM vacuum technology has been applied to the iKon M UltraVac provides a permanent hermetically sealed enclosure for maximum QE and cooling performance over many years operation Camera Window The iKon M features a Single AR coated UV grade silica window for optimum transmission For more information on camera windows please see http www andor com learning academy camera windows o...

Page 15: ...stomer end should be high impedance not 50Ω as an incorrect impedance match could cause errors with timing and triggering The SMB Ext Trig input is TTL level CMOS compatible and has 470Ω impedance I2 C The I2 C provides a connection option via the I2 C interface Compatible with Fischer type SC102A054 130 connector 1 Shutter TTL 2 I2 C Clock 3 I2 C Data 4 5 Vdc 5 Ground Power Power input connection...

Page 16: ...ptional PS 25 PSU can be used to achieve maximum cooling and has 2x settings STANDARD COOLING or DEEP COOLING The connection to the iKon M is also made via a 5 pin DIN socket 2 4 Power Requirements Ensure that the power connector for the iKon M camera is inserted securely The connector is keyed to aid correct orientation Power Input 100 240V 50 60Hz 1 6A The electrical mains lead should be certifi...

Page 17: ...t all liquid coolant has been expelled from the camera 3 2 C mount The standard iKon M 912 and 934 models feature a C mount for lens fitting Adapters are also available for AF F and T mount attachment Refer to Section 1 5 2 3 3 Mounting the iKon M using the Mounting Flange The standard iKon M mounting flange has mounting holes to clear either 4 x 6 32 UNC or 4x M4 fittings For further information ...

Page 18: ...on on internal components When using a liquid cooling system it is recommended that an overpressure device is fitted to avoid leaks that may find their way to the mains electricity supply and create a hazard Never use damaged split or worn hoses The coolant connectors are factory fitted and sealed they cannot be removed Always remove residual coolant from the camera head if the camera is to be sto...

Page 19: ...w rate and cooling efficiency The specified cooling performance of the camera can be achieved with coolant flow rates of 2 litres per minute the maximum recommended pressure of coolant circulating through the camera head is 2 bar 30 PSI 3 9 Connecting the Liquid Cooling System An overview for connecting a liquid cooling system is outlined below please refer to the information supplied with your co...

Page 20: ... installation of software and drivers on your computer network 4 When prompted select iKon M 5 Continue installation and restart your computer when prompted to successfully complete the installation 6 The shortcut icon for Solis will appear on the desktop on re start 7 The iKon M is now ready to be connected to a PC laptop and powered on 3 10 3 New Hardware Wizard When the iKon M camera is connect...

Page 21: ... computer 2 Open the PC enclosure to gain access to the expansion slots 3 Locate a suitable PCIe slot for a USB 2 0 cards 4 If you are unsure which slot is correct please consult the PC user manual 5 Remove the filler bracket corresponding to the slot you intend to use 6 Remove the PCIe card carefully from its protective ESD packaging and insert the card connector fully into the expansion slot 7 E...

Page 22: ...der control of the software and you are ready to use the camera 6 Refer to your software manual for set up and image acquisition information 4 3 Power Down Sequence 1 Exit the camera control software 2 The camera will automatically turn off 3 Switch off power to the camera and if not using for some time disconnect from the mains power socket 4 4 Using the iKon M Once set up the iKon M is controlle...

Page 23: ...he exposed nature of the sensor extreme care should be taken with the camera as damage can easily occur through mishandling or by contamination If the sensor becomes contaminated due to accident or misuse please contact Andor immediately for advice on cleaning Vacuum Operations NOTE Do not operate the iKon M in a vacuum that exceeds i e lower pressure 1 33 x 10 8 mb 10 8 Torr Ensure that the vacuu...

Page 24: ...or The holder will accept an insert of Ø 45 5 mm up to 1 0 mm thick 4 To load an insert grip the holder by hand across the flats and turn until the reference spot on the holder aligns with the reference spot on the flange i e 5 The holder can now be withdrawn from the flange 6 Remove the 5 off M3 x 6 countersunk screws and lift off the upper plate of the filter holder 7 Set the insert into the rec...

Page 25: ...60 16 2 11 25 either side of TDC 2 A ball spring plunger in the circumference of the rotatable rim will index to positions on or either side of TDC with reference to the space between water connectors 3 Up to 6 of the 16 holes may be obstructed from screw access depending on the orientation of the rim These positions will be behind the water connectors and at the bottom corners of the camera body ...

Page 26: ...t 9 The camera can now be assembled onto the customer flange An open ended wrench is required to tighten the M8 screws Please observe the torque pattern recommended for the ICF 152 5 2 iKon M SY The iKon M SY model has a Beryllium foil window as opposed to a standard window This enables direct soft X ray detection 5 2 1 Best Practice Guidelines When not in use the window should be covered and prot...

Page 27: ... cleaner Never spray liquids directly on the camera apply cleaning solution to the cloth then wipe the camera body with the dampened cloth Do not use abrasive or other detergents to clean the camera 6 4 Cleaning the Camera Window At some point it may become necessary to clean debris that may have settled on the CCD imaging sensor window Cleaning the camera window can provide effective results prov...

Page 28: ...particles onto the camera window 3 With the shutter open turn the camera on its side making it easier for particles to fall out of the camera head Face the window toward you at the edge of a table 4 Give the window short blasts of compressed air to work dust particles out of the camera head 5 If there are still particles stuck on the window use an optics brush to very carefully dislodge them from ...

Page 29: ...s are attached If this occurs carry out the following actions 1 Switch off the system 2 Wipe the camera with a soft dry cloth NOTE It is likely there will already be condensation on the cooling block and cooling fins inside the camera 3 Set the camera aside to dry for several hours before you attempt reuse 4 Before reuse blow dry gas through the cooling slits on the side of the camera to remove an...

Page 30: ...gory CAT II An overvoltage category of CAT II means that the equipment is designed to cope with transient voltages above the rated supply that would be experienced by any product connected to a mains socket in a building Rated Pollution Pollution Degree 2 Normally only non conductive pollution occurs Occasionally however a temporary conductivity caused by condensation must be expected Cooling vent...

Page 31: ...NC 4 off mountings M4 x 5 deep 2 44 62 0 3 54 90 0 2 52 64 0 4 13 105 0 2 04 52 0 52 0 2 04 Air in air exit opposite side Focal Plane of Detector 208 4 8 2 3 off 1 4 20 UNC x 1 2 deep 2 off M6 x 10 deep 1 0 25 4 25 4 1 0 13 0 0 51 1 0 25 4 13 0 0 51 position of pixel 1 1 n n Power External trigger SMB Fire SMB I C Connector Lockable USB 2 0 Shutter SMB ...

Page 32: ...untings M4 x 5 deep 90 0 3 54 52 0 2 04 105 0 4 13 2 44 62 0 64 0 2 52 52 0 2 04 Focal Plane of Detector 208 4 8 2 3 off 1 4 20 UNC x 1 2 deep 2 off M6 x 10 deep 13 0 0 51 1 0 25 4 1 0 25 4 25 4 1 0 13 0 0 51 connector Power I C Lockable USB 3 x SMB n position of pixel 1 1 n iKon M PV Inspector ...

Page 33: ...2 o clock position 2 off water connectors o suit 6 0 mm ID hose Position of pixel 1 1 Light tight pressure balancing hole Ø151 6 5 96 Knife edge Ø113 9 4 48 Rotation index block 42 5 1 67 3 2 0 12 197 1 7 76 Note Image plane of sensor Filter Holder with bayonet twist fitting for ease of insertion and removal Suitable filter Ø45 5 mm 1 79 iKon M SY Weight 2 2 kg 4 lb 13 oz n pixel 1 1 n iKon M SO 4...

Page 34: ...ll be on the coolant connections entering and exiting the camera Use of coolant at or below the dewpoint can result in permanent damage to the camera head due to formation of condensation on internal components It is therefore very important to ensure that coolant temperature is above the dewpoint Further guidelines are provided in Section 7 1 The relationship between Relative Humidity and Dew Poi...

Page 35: ...value is 100 years Outgassing is minimized through assembly in a state of the art facility with a stringent protocol and use of proprietary materials Outgassing is the release of trapped gasses that would otherwise degrade cooling performance and potentially cause sensor failure UltraVac also features a single camera window for the best optical performance For more information about our UltraVac t...

Page 36: ... warranty conditions will have been made available during the ordering process The current version may be viewed at www andor com pdfs literature Andor_Standard_Warranty pdf Waste Electronic and Electrical Equipment Regulations 2006 WEEE The company s statement on the disposal of WEEE can be found in the Terms and Conditions found on the Andor website WEEE Policy ...

Page 37: ...______________________________________________________ ___________________________________________________________________ ___________________________________________________________________ ___________________________________________________________________ ___________________________________________________________________ ___________________________________________________________________ ...

Reviews: