61
NIRA Internal
fault code
J1939
SPN
J1939
FMI
Description
148
Trim position pump - Control error
150
100
1
Engine oil pressure - Data valid but below normal operational range
151
651
5
Fuel injector 1, Cylinder 1 - Open curcuit
152
652
5
Fuel injector 2, Cylinder 2 - Open curcuit
153
653
5
Fuel injector 3, Cylinder 3 - Open curcuit
154
654
5
Fuel injector 4, Cylinder 4 - Open curcuit
159
DG_FNO_GEAR_POSITION_FAULT
166
Fuel pump relay - Electrical fault
167
Trolling valve - Electrical fault
174
Hydraulic oil pressure - Data valid but above normal operational range
175
Hydraulic oil pressure - Data valid but below normal operational range
176
Hydraulic oil temperature - Data valid but above normal operational range
177
DG_FNO_OIL_LEVEL_LOW
179
97
31
DG_FNO_WATER_IN_FUEL
188
110
0
DG_FNO_COOLANT_TEMPERATURE
189
1136
0
DG_FNO_ECU_TEMPERATURE
190
175
0
DG_FNO_OIL_TEMPERATURE
191
2899
12
DG_FNO_GPC_MODULE
192
5324
31
DG_FNO_GPC_MODULE
193
DG_FNO_GPC_MODULE_COM
194
2433
2433
Exhaust gas temperature - Data valid but above normal operational range
196
171
171
Ambiant air temperature - Data valid but above normal operational range
198
107
107
Air filter pressure sensor - Data valid but below normal operational range
199
DG_FNO_COOLANT_LEVEL_LOW
200
Control head CAN RX time-out
Te
ch
ni
ca
l d
at
a
M
ai
nt
ena
nc
e
O
per
at
in
g
O
ve
rv
ie
w
Summary of Contents for OXE-200 HP
Page 1: ...USER MANUAL OXE 200 HP ...
Page 3: ...Overview 3 INTRODUCTION Publication No ODM1005 Maintenance Operating Technical data ...
Page 4: ......
Page 34: ...28 OPERATING ...
Page 68: ...62 MAINTENANCE TROUBLE SHOOTING Refer to Service Manual ...
Page 72: ......