background image

 

General Warranty

 

OWON warrants that the product will be free from defects in materials and workmanship for a period 
of 3 years (1 year for accessories) from the date of purchase of the product by the original purchaser 
from the OWON Company. This warranty only applies to the original purchaser and is not transferable 
to the third party. 

 

If the product proves defective during the warranty period, OWON either will repair the defective 
product without charge for parts and labor, or will provide a replacement in exchange for the defective 
product. Parts, modules and replacement products used by OWON for warranty work may be new or 
reconditioned like new performance. All replaced parts, modules and products become the property of 
OWON. 

 

In order to obtain service under this warranty, customer must notify OWON of the defect before the 
expiration of the warranty period. Customer shall be responsible for packaging and shipping the 
defective product to the service center designated by OWON, and with a copy of customer proof of 
purchase. 

 

This warranty shall not apply to any defect, failure or damage caused by improper use or improper or 
inadequate maintenance and care. OWON shall not be obligated to furnish service under this warranty 
a) to repair damage resulting from attempts by personnel other than OWON representatives to install, 
repair or service the product; b) to repair damage resulting from improper use or connection to 
incompatible equipment; c) to repair any damage or malfunction caused by the use of non-OWON 
supplies; or d) to service a product that has been modified or integrated with other products when the 
effect of such modification or integration increases the time or difficulty of servicing the product. 

 

Please contact the nearest OWON's Sales and Service Offices for services. 

 

For better after-sales service, please visit 

www.owon.com.cn 

and register the purchased product online. 

 

Excepting the after-sales services provided in this summary or the applicable warranty 
statements, OWON will not offer any guarantee for maintenance definitely declared or hinted, 
including but not limited to the implied guarantee for marketability and special-purpose 
acceptability. OWON should not take any responsibilities for any indirect, special or consequent 
damages. 

 

For more details, please refer to the user manual on the supplied CD, it can also be downloaded at 

www.owon.com.cn 

 

Summary of Contents for XDG2000 Series

Page 1: ...amage caused by improper use or improper or inadequate maintenance and care OWON shall not be obligated to furnish service under this warranty a to repair damage resulting from attempts by personnel other than OWON representatives to install repair or service the product b to repair damage resulting from improper use or connection to incompatible equipment c to repair any damage or malfunction cau...

Page 2: ...dit the arbitrary waveform 11 Generate the Modulated Waveform 12 Generate Sweep 13 Generate Burst 13 Counter 14 File Store System 15 Save the current arbitrary wave 15 Bring up arbitrary wave files in internal external memory 16 Erase waveforms from memory 16 Save recall instrument setup 17 Utility Setting 17 5 Communicate with PC 19 Using USB Port 19 Using LAN Port 19 Connect Directly 19 Connect ...

Page 3: ...of this product Refer to the user s manual for the Measurement Limits before connecting to the instrument Do not exceed any of the Measurement Limits defined in the following section Do not operate without covers Do not operate the instrument with covers or panels removed Use Proper Fuse Use only the specified type and rating fuse for this instrument Avoid exposed circuit Do not touch exposed junc...

Page 4: ...itions or practices that could result in damage to this product or other property Terms on the Product The following terms may appear on this product Danger It indicates an injury or hazard may immediately happen Warning It indicates an injury or hazard may be accessible potentially Caution It indicates a potential damage to the instrument or other property might occur Safety Symbols Symbols on th...

Page 5: ...check whether there is any loss of accessories with reference to this description If it is found that there is any accessory lost or damaged please get in touch with the distributor of OWON responsible for this service or the OWON s local offices 3 Check the Complete Instrument If it is found that there is damage to the appearance of the instrument or the instrument can not work normally or fails ...

Page 6: ...ted waveform Sweep scan the sine square ramp or arbitrary waveforms Burst generate the sine square ramp pulse or arbitrary burst 4 Knob Change the currently selected value also used to select the character in the soft keyboard when the file location or file name is entered When inserting a USB flash drive press the knob to save the current display screen to the folder of the USB flash drive in BMP...

Page 7: ...ger button CH2 manual trigger button In sweep or burst mode when the trigger source is selected as Manual each press of this button will initiate a trigger On Off button Turns the output of the CH2 channel on or off When the output is turned on the backlight of the button lights up 9 CH2 Sync When Utility CH1 2 Set CH2 Sync turned on this terminal outputs a synchronization message that matches the...

Page 8: ... Selection area Includes Sine Square Ramp Pulse Noise Arb Wave Harmonic Wave When a waveform is selected the corresponding backlight is lit 16 DGO button Digital output only for the model with digial output function 17 Digital channel Digital signal Output connector only for the model with digial output function 18 USB interface Connect with external USB devices e g U disk 19 Power button Turn on ...

Page 9: ...ter input signal Used to receive a 10MHz clock signal when the instrument is set to an internal clock source and Utility System CLK Output is turned on it is used to receive an external 10MHz clock signal when the instrument is set to an external clock source 11 Mod FSK Trig modulation trigger input connector When modulating the waveform outputting the sweep frequency and outputting the burst the ...

Page 10: ...ent waveform or current mode 3 Trigger source Internal Internal modulation or internal trigger source External External modulation or external trigger source Manual Manual trigger source 4 Load High Z indicates high resistance 5 This indicator is lit when the network is connected through the LAN interface 6 Lights up the indicator when connected to the USB Host via the USB DEVICE interface 7 When ...

Page 11: ...ct the channel for configuration Before configuring waveform parameters you must first select the channel you want to configure Press CH1 or CH2 to select the corresponding channel and the corresponding channel area in the user interface will light up Turn on off channel output Press CH1 On Off or CH2 On Off on the front panel to turn on off the corresponding channel output The channel will light ...

Page 12: ...ss the arrow keys to move the cursor left or right Press a number key on the numeric keypad directly the screen will pop out of the data input box continue to input the desired value Press the key to delete the last digit Press the right menu soft key to select the unit of the parameter Press the Cancel softkey to cancel the current entry Figure 4 4 Use numeric keypad to set the frequency Paramete...

Page 13: ...t the arbitrary waveform Press the Edit on front panel to enter the arbitrary edit interface 1 Set the wave points Press the Points softkey turn the knob to adjust the value or use the numeric keypad and press unit softkey Range between 2 to 100 000 2 Select the template Press the Basic Template softkey to select Blank Sine wave Square wave Ramp wave and Noise Press the Arb Template softkey to sel...

Page 14: ...yboard appears on the screen Turn the knob to select a character Press the ABC abc softkey to toggle the case of keyboard characters Press the Select softkey to enter the current character Press the Delete softkey to delete the last character that has been entered Press the Done softkey to finish editing and the waveform will be saved in the bin file format under the current path Generate the Modu...

Page 15: ...ource DSB_ AM Internal source Shape AM Frequency External source Generate Sweep In the frequency sweep mode the generator steps from the start frequency to the stop frequency at the sweep rate you specify Sweep can be generated by Sine Square Ramp or Arbitrary waveforms When the output signal is Sine Square Ramp or Arbitrary waveform press the front panel Sweep key to enter the sweep mode the back...

Page 16: ... large signals or signals with slow rising edges low sensitivity is selected and the measurement results are more accurate Press the HFR softkey to toggle On or Off high frequency rejection High frequency rejection can be used to filter high frequency factors when measuring low frequency signals improving measurement accuracy When measuring low frequency signals with a frequency less than 1 kHz tu...

Page 17: ...he file system If you want to save the current arbitrary waveform to the internal memory select INTER and press the Arb file softkey Turn the knob to select one of the USER files EditMemory cannot be selected and press the Save softkey The file size is displayed on the right side of the USER file If 0B is displayed it means the file is empty Description EditMemory is a temporary data space created...

Page 18: ... file in the USB storage device turn the knob to select USBDEVICE in the memory selection interface Press the Arb file softkey and the instrument will list the directories of the folders and files in the USB storage device Turn the knob to select a folder or file Select the file with the suffix of bin and press the CallOut softkey If the reading is successful the screen will prompt File Read Succe...

Page 19: ...size is displayed on the right side of the Setup file If 0B is displayed it means the file is empty Note Press the Secure softkey and then press the OK softkey to clear all the settings in the internal memory To recall a setup select the desired setup and press the CallOut softkey Utility Setting Press the front panel Utility function key to enter the system options menu The user can set the displ...

Page 20: ...n computer via the USB Device interface USBTMC Select this when you need to use the USBTMC communication protocol standard Network Network parameters while communicating with a computer using a LAN interface System Setting Language Select instrument interface language Beeper If On it makes sounds when prompted CLK Ref Internal or External CLK Output When the instrument is set to the internal clock...

Page 21: ... the Waveform Editor communication software is located such as C Program Files x86 DS_Wave Waveform Editor USBDRV 4 Host computer communication port setting Open the Waveform Editor software click Communications in the menu bar select Ports Settings in the setting dialog box select the communication port as USB After the connection is successful the connection status prompt in the lower right corn...

Page 22: ... to the router with a network cable The computer is also connected to the router 2 Set the network parameters of the computer Since the signal generator does not support automatic IP address acquisition you need to specify the IP yourself The default gateway and subnet mask settings must match the settings of the router For example the IP address is set to 192 168 1 71 the subnet mask is set to 25...

Page 23: ...he submenu Set the IP address and port to the IP and port in the PC software port settings in step 3 The gateway settings need to be the same as the gateway settings of the router After the shutdown and restart if the data can be obtained normally in the PC software the connection is successful For the specific operation method of Waveform Editor software please press F1 to view the built in help ...

Page 24: ... often as operating conditions require To clean the instrument exterior perform the following steps 1 Wipe the dust from the instrument and probe surface with a soft cloth Do not make any scuffing on the transparent LCD protection screen when clean the LCD screen 2 Disconnect power before cleaning your instrument Clean the instrument with a wet soft cloth not dripping water It is recommended to sc...

Reviews: