background image

 

User’s Manual of 

OWON

 Colour Digital Storage Oscilloscope

 

 

 1 

 

OWON  

 

 

 

PDS 6062T   

 

Portable Digital Storage Oscilloscope   

 

 

User's Manual   

 

 

 

 

 

 

 

 

WWW.OWON.COM.CN 

Summary of Contents for PDS6062T

Page 1: ...User s Manual of OWON Colour Digital Storage Oscilloscope 1 OWON PDS 6062T Portable Digital Storage Oscilloscope User s Manual WWW OWON COM CN ...

Page 2: ...ca and other countries including ones which have already obtained the patent rights and those which are applying for The information in this manual will replace all that in the materials published originally Reserved will be the rights to change product specifications and prices Lilliput Company the 5th floor B Area Chuangxin Mansion Xiamen Software Zone OWON is the registered trademark of the Lil...

Page 3: ...od the Lilliput will offer repairing and changing services according to those described in the complete warranty statement Please contact the nearest Lilliput s Sales and Service Offices for services or a complete copy of the warranty statement Excepting the after sales services provided in this summary or the applicable warranty statements Lilliput will not offer any guarantee for maintenance def...

Page 4: ...d changing services according to those described in the complete warranty statement Please contact the nearest Lilliput s Sales and Service Offices for services or a complete copy of the warranty statement Excepting the after sales services provided in this summary or the applicable warranty statements Lilliput will not offer any guarantee for maintenance definitely declared or hinted including bu...

Page 5: ...e Attenuation Coefficient 20 How to Use the Probe Safely 21 How to Implement Auto calibration 22 Introduction to the Vertical System 23 Introduction to the Horizontal System 24 Introduction to the Trigger System 25 Advanced User s Guidebook 26 How to Set the Vertical System 27 Implementation of Mathematical Manipulation Function 33 Application of VERTICAL POSITION and VOLTS DIV Knobs 34 How to Set...

Page 6: ...asurement 60 Cursor Measurement 61 How to Use Executive Buttons 63 AUTOSET 63 Examples of Application 64 Example 1 Measurement of Simple Signals 64 Example 2 Gain of the Amplifier in the Metering Circuit 65 Example 3 Capture the Single Signal 66 Example 4 Analyze the Details of a Signal 68 Example 5 Application of X Y Function 70 Example 6 Video Signal Trigger 71 Fault Treatment 74 Appendix A Tech...

Page 7: ...esponds to the grounding phase Please don t connect the grounding end to the positive phase Pay attention to the nominal values of all terminals In order to prevent any fire or electric shock risks please pay attention to all the nominal values and marks of this product Before implement any connections for this product please read the user s manual of this product to understand the information abo...

Page 8: ...ct or other property Terms on the product The following terms may appear on this product Danger It indicates that there may be an immediate injury to you when you encounter this mark Warning It indicates that there may not be an immediate injury to you when you encounter this mark Note It indicates that there may be damage to this product or other property Symbols on the products The following sym...

Page 9: ...re 42V peak 30Vrms or on circuits of more than 4800VA z Only use accessory insulated voltage probes test lead z Before use inspect oscilloscope probes accessories for mechanical damage and replace when damage z Remove all probes test leads and accessories that are not in use z Remove computer data line z Do not apply input voltages above the rating of the instrument Use caution when using 1 1 test...

Page 10: ...ement functions Color liquid crystal display of high resolution and high contrast with adjustable back light Storage and call out of waveforms Automatic setting function provided capable of fast setting Multiple waveform calculation function Implementation of detecting the average and peak values of the waveform Digital real time oscilloscope Edge and video triggering function RS232 or USB communi...

Page 11: ...nterface of the PDS series oscilloscope z How to carry on the general inspection z How to carry on the function inspection z How to make a probe compensation z How to set the probe attenuation coefficient z How to use the probe safely z How to implement an auto calibration z Introduction to the vertical system z Introduction to the horizontal system z Introduction to the trigger system ...

Page 12: ...se of the PDS series oscilloscope in the shortest time The PDS series oscilloscope offers a simple front panel with distinct functions to users for their completing some basic operations in which the knobs and function pushbuttons are included The knobs have the functions similar to other oscilloscopes The 5 buttons in the column on the right side of the display screen are menu selection buttons d...

Page 13: ...lloscope Fig 1 The Front Panel of a PDS series Oscilloscope Function Buttons Vertical Control Adjustment Menu Selection Horizontal Control Trigger Control Back light Connector Fig 2 Explanatory Drawing for Operations of the PDS series Oscilloscope 13 ...

Page 14: ...dy for accepting a trigger Scan The oscilloscope captures and displays the waveform data continuously in the scan mode Stop The oscilloscope has already stopped the waveform data acquisition 2 Waveform Viewing Area 3 The purple pointer indicates the horizontal trigger position which can be adjusted by the horizontal position control knob 4 The reading shows the time deviation between the horizonta...

Page 15: ...nel indicates the direct current coupling indicates the AC coupling 16 The reading shows the vertical scale factor the Voltage Division of the CH2 channel 17 The icon indicates the coupling mode of the CH1 channel The icon indicates the direct current coupling The icon indicates the AC coupling 18 The reading indicates the vertical scale factor the Voltage Division of the CH1 channel 19 The inform...

Page 16: ...of this Manual You can check whether there is any loss of accessories with reference to this description If it is found that there is any accessory lost or damaged please get in touch with the distributor of LILLIPUT responsible for this service or the LILLIPUT s local offices 3 Check the Complete Instrument If it is found that there is damage to the appearance of the instrument or the instrument ...

Page 17: ...Press the UTILITY button to get access to the FUNCTION menu and push down F2 the menu selection button to call out the function Recall Factory The default attenuation coefficient set value of the probe in the menu is 10X shown as Fig 4 Fig 4 Power on the Instrument 2 Set the Switch in the Oscilloscope Probe as 10X and Connect the Oscilloscope with CH1 Channel Align the slot in the probe with the p...

Page 18: ...scilloscope Probe comp CH1 Fig 5 Connection of the Probe 3 Press the AUTOSET Button The square wave of 1 KHz frequency and 5V peak peak value will be displayed in several seconds see Fig 6 Fig 6 Auto set Check CH2 by repeating Step 2 and Step 3 18 ...

Page 19: ...t of the probe in the menu as 10X and that of the switch in the probe as 10X and connect the oscilloscope probe with the CH1 channel If a probe hook tip is used ensure that it keeps in close touch with the probe Connect the probe tip with the signal connector of the probe compensator and connect the reference wire clamp with the ground wire connector of the probe connector and then press the butto...

Page 20: ...ue is shown This setting will be valid all the time before it is changed again Note The attenuation coefficient of the probe in the menu is preset to 10X when the oscilloscope is delivered from the factory Make sure that the set value of the attenuation switch in the T5100 probe is the same as the menu selection of the probe in the oscilloscope The set values of the probe switch are 1X and 10X see...

Page 21: ...void suffering from the electric shock please keep your finger behind the safety guard ring of the probe body during the operation In order to protect you from suffering from the electric shock during your using the probe do not touch the metal part of the probe tip when the probe is connected to the power supply Before making any measurements please connect the probe to the instrument and connect...

Page 22: ... application program at any time but when the range of variation of the ambient temperature is up to or over 5 this program must be executed For the performing of the self calibration all probes or wires should be disconnected with the input connector first Then press the UTILITY button to call out the FUNCTION menu push down the F3 menu selection button to choose the option Do Self Cal finally ru...

Page 23: ...pidly measure the DC component of the signal through the observation of the difference between the wave form and the signal ground If the channel is under the AC mode the DC component will be removed by filtration This mode helps you display the AC component of the signal with a higher sensitivity 2 Change the Vertical Setting and Observe the Consequent State Information Change With the informatio...

Page 24: ...he horizontal time base and it can be found that the Horizontal Time Base display in the status bar changes accordingly The horizontal scanning speed steps from 5ns up to 5s in the sequence of 1 2 5 2 Use the HORIZONTAL POSITION knob to adjust the horizontal position of the signal in the waveform window The HORIZONTAL POSITION knob is used to control the triggering displacement of the signal or fo...

Page 25: ...ed 2 Use the LEVEL knob to change the trigger level setting With the rotation of the LEVEL knob it can found that the trigger indicator in the screen will move up and down with the rotation of the knob With the movement of the trigger indicator it can be observed that the trigger level value displayed in the screen changes 3 Press the button SET TO 50 to set the trigger level as the vertical mid p...

Page 26: ...iliar with the above mentioned operations and methods yet we advise you to read the section of Chapter One Junior Users Guidebook This chapter will deal with the following topics mainly z How to Set the Vertical System z How to Set the Horizontal System z How to Set the Trigger System z How to Carry on the Sampling Setup z How to Set the Display System z How to Implement the Storage and Call out O...

Page 27: ...NU and four knobs such as VERTICA POSITION VOLTS DIV one group for each of the two channels Setting of CH1 and CH2 Every channel has an independent vertical menu and each item is set respectively based on the channel With the CH1 MENU or CH2 MENU menu button pushed down the system shows the operation menu of the corresponding channel see Fig 14 Fig 14 Channel Setting Menu 27 ...

Page 28: ...displayed normally Initiate the wave form inverted function 1 Setting Channel Coupling Taking the Channel 1 for example the measured signal is a square wave signal containing the direct current bias The operation steps are shown as below 1 Press the CH1 MENU button and call out the CH1 SETUP menu 2 Press the F1 menu selection button and select the Coupling item as AC to set the channel coupling as...

Page 29: ...User s Manual of OWON Colour Digital Storage Oscilloscope Fig 15 AC Coupling Oscillogram Fig 16 DC Coupling Oscillogram 29 ...

Page 30: ...st the attenuation ration coefficient of the probe through the operating menu of the Channel accordingly If the attenuation coefficient of the probe is 1 1 that of the oscilloscope input channel should also be set to 1X to avoid any errors presented in the displayed scale factor information and the measured data Take the Channel 1 as an example the attenuation coefficient of the probe is 1 1 the o...

Page 31: ...he displayed signal is turned 180 degrees against the phase of the earth potential Taking the Channel 1 for example the operation steps are shown as follows 1 Press the CH1 MENU button and get access to the CH1 SETUP menu 2 Press the F4 menu selection button and select ON in the Inverted The wave form inverted function is initiated 3 Press the F4 menu selection button again and select OFF for Inve...

Page 32: ...User s Manual of OWON Colour Digital Storage Oscilloscope Fig 18 Wave Form not Inverted Fig 19 Wave Form Inverted 32 ...

Page 33: ...n and call out the WAVE MATH menu 2 Press the F3 menu selection button and choose CH1 CH2 The green calculated wave form M is displayed in the screen press the F3 menu selection button again the wave form M is closed off see Fig 20 Fig 20 Wave Form resulted from CH1 CH2 Mathematical Manipulation The corresponding FCL Functional Capabilities List of the Wave Form Calculation Setting Description CH1...

Page 34: ...V knob is used to regulate the vertical resolution of the wave forms of all channels including those obtained from the mathematical manipulation which can determine the sensitivity of the vertical division with the sequence of 1 2 5 The vertical sensitivity goes up when the knob is rotated clockwise and goes down when the knob is rotated anticlockwise 3 When the vertical position of the channel wa...

Page 35: ...hich changes with the time base 2 SEC DIV knob it is used to set the horizontal scale factor for setting the main time base or the window 3 HORIZONTAL NENU button with this button pushed down the screen shows the operating menu see Fig 22 Fig 22 Time Base Mode Menu The description of the Horizontal Menu is as follows Function Menu Setting Description Main Time Base The setting of the horizontal ma...

Page 36: ...illoscope Main Time Base Press the F1 menu selection button and choose the Main Time Base In this case the HORIZONTAL POSITION and SEC DIV knobs are used to adjust the main window The display in the screen is shown as Fig 23 Fig 23 Main Time Base 36 ...

Page 37: ...ss the F2 menu selection button and choose Set Window The screen will show a window area defined by two cursors In this case the HORIZONTAL POSITION and SEC DIV knobs can be used to adjust the horizontal position and size of this window area see Fig 24 Fig 24 Window Setting 37 ...

Page 38: ... Digital Storage Oscilloscope Window Expansion Press the F3 menu selection button and choose Zone Window As a result the window area defined by two cursors will be expanded to the full screen size see Fig 25 Fig 25 Zone Window 38 ...

Page 39: ...e oscilloscope will continuously collect data enough to draw the wave form at the right side of the trigger point One knob and four function menu buttons are included in the trigger control zone LEVEL Trigger the level control knob and set the signal voltage corresponding to the trigger point SET TO 50 Set the trigger level as the vertical mid point value of the amplitude of the trigger signal FOR...

Page 40: ...rigger input passes through a given level along the set direction Video Trigger Carry out the field or line video trigger of the standard video signal The Edge and Video Trigger menus are described respectively as below Edge Trigger Under the Edge Trigger mode a trigger happens in the trigger threshold value of the input signal edge When the Edge Trigger is selected a trigger will occur in the ris...

Page 41: ... trigger is detected and then stop sampling Coupling DC AC HF Rjc LF Rjc Block the direct current component Unblock all components Block the high frequency signal and only unblock the high frequency component Block the low frequency signal and only unblock the low frequency component Make such settings in Channel 1 as Rising for Slop Auto for Mode and DC for Coupling The operation steps are as fol...

Page 42: ...User s Manual of OWON Colour Digital Storage Oscilloscope Fig 28 Wave Form Triggered on the Rising Edge Fig 29 Wave Form Triggered on the Falling Edge 42 ...

Page 43: ...n Menu Setting Description Polarity Normal Inverted Applicable to the video signal of low black level Applicable to the video signal of high black level Source CH1 CH2 EXT EXT 5 Set Channel 1 as the trigger signal of the source Set Channel 2 as the trigger signal of the source Set the external input channel as the trigger signal of the source Divide the external trigger source by 5 and expand the ...

Page 44: ... 2 Press the F1 menu selection button and choose Video for Type 3 Press the F2 menu selection button and choose Normal for Polarity 4 Press the F3 menu selection button and choose CHI1 for Source 5 Press the F4 menu selection button and choose Field for Sync The screen display is shown as Fig 31 6 Press the F4 menu selection button again and choose Line for Slope The screen display is shown as Fig...

Page 45: ...User s Manual of OWON Colour Digital Storage Oscilloscope Fig 31 Wave Form Triggered in the Video Field Fig 32 Wave Form Triggered in the Video Line 45 ...

Page 46: ... Press the ACQUIRE button and the menu is displayed in the screen shown as Fig 33 Fig 33 ACQU MODE Menu The description of the Sampling Setup Menu is shown as follows Function Menu Setting Description Sampling General sampling mode Peak Detection It is used for the detection of the jamming burr and the possibility of reducing the confusion Average value It is used to reduce the random and don t ca...

Page 47: ...torage Oscilloscope Change the ACQU Mode settings and observe the consequent variation of the wave form displayed Fig 34 Peak Detect mode under which the burrs on the falling edge of the square wave can be detected and the noise is heavy 47 ...

Page 48: ...olour Digital Storage Oscilloscope Fig 35 Common ACQU Mode display in which no burr can be detected Fig 36 The displayed wave form after the noise is removed under the Average Mode in which the average number of 64 is set 48 ...

Page 49: ...ween the adjacent sampling points in the display is filled with the vector form Only the sampling points are displayed Persist OFF 1sec 2sec 5sec Infinite Set the persistence time for each sampling point Format YT XY Show the relative relation between the vertical voltage and the horizontal time Channel 1 is displayed on the horizontal axis and Channel 2 on the vertical axis Carry Bitmap Vectors T...

Page 50: ...pe With the F1 menu selection button pushed down you can shift between Vectors and Dots types The differences between the two display types can be observed through the comparison between Fig 38 and Fig 39 Fig 38 Display in the Vector Form Fig 39 Display in Dots form 50 ...

Page 51: ...is changed see Fig 40 Fig 40 Infinite Persistence Display XY Format This format is only applicable to Channel 1 and Channel 2 After the XY display format is selected Channel 1 is displayed in the horizontal axis and Channel 2 in the vertical axis the oscilloscope is set in the untriggered sample mode the data are displayed as bright spots and the sampling rate is 1MS s and can not be changed The o...

Page 52: ...ormat Reference or digital wave form Cursor Auto Set Time base control Trigger control Operation steps 1 Press the DISPLAY button and call out the Display Set Menu 2 Press the F3 menu selection button and choose the form as XY The display format is changed to be XY mode see Fig 41 Fig 41 XY Display Mode 52 ...

Page 53: ...as Fig 42 Fig 42 Wave Form Save Menu The description of the Wave Form Save Menu is shown as the following table Function Menu Setting Description Source CH1 CH2 MATH Choose the wave form to be saved WAVE A B C D Choose the address in or from which the waveform is saved or can be get access to Save Save the wave form of the source in the selected address CHA OFF ON Switch on or off the display of t...

Page 54: ...CH1 into the address A the operation steps should be followed 1 Press the F1 menu selection button and choose CH1 for Source 2 Press the F2 menu selection button and choose A for Wave 3 Press the F3 menu selection button and save the wave form 4 Press the F4 menu selection button and choose ON for CHA The stored wave form A will be displayed in the screen The voltage level and time base level will...

Page 55: ...creen as Fig 45 Fig 45 Function Menu The description of the Auxiliary Function Menu is shown as the following table Function Menu Setting Description System Status Display the system function menu Recall Factory Call out the factory settings Do Self Cal Carry out the self calibration procedure Language Chinese ENGLISH Choose the display language of the operating system 55 ...

Page 56: ...dure should be executed to obtain the highest level of accuracy Before executing the self calibration procedure disconnect the probe or wire and the input connector Then press the F3 menu selection button and choose Do Self Cal After confirming it is all set push down F3 button and choose Do Self Cal entering the self calibration procedure of the instrument SYS STAT System State Press the F1 menu ...

Page 57: ...l Trigger Show the parameters of the trigger system Misc Adjust the Date and Time After entering into the SYS STAT menu choose the corresponding function with the corresponding parameters shown in the screen If press the F1 menu selection button and choose the function item Horizontal the Horizontal System State will be displayed in the screen Press any other function button and exit from the SYS ...

Page 58: ...hannel to be measured from the Source menu and choose the measurement Type Freq Cycle Mean PK PK RMS and None The menu is displayed as Fig 48 Fig 48 Measure Menu Measure Four automatic measured values can be shown one time at maximum for the wave form of each channel Only if the wave form channel is in the ON state can the measurement be carried out No automatic measurement can be made for the sav...

Page 59: ...he F4 menu selection button and choose CH2 5 Press the F5 menu selection button and choose CH2 6 Press the F1 menu selection button and choose Type 7 Press the F2 menu selection button and choose Freq 8 Press the F3 menu selection button and choose Pk Pk 9 Press the F4 menu selection button and choose Mean 10 Press the F5 menu selection button and choose Cyc RMS The measured value will be displaye...

Page 60: ...cription Type OFF Voltage Time Switch off the cursor measurement Display the voltage measurement cursor and menu Show time measures the cursor and menu Source CH1 CH2 Choose the channel generating the wave form to which the cursor measurement will be applied Delta Read the difference between cursors Cursor 1 Read the position of Cursor 1 the Time is read with reference to the horizontal trigger po...

Page 61: ...u 2 Press the F1 menu selection button to choose Voltage for Type with two purple dotted lines displayed along the horizontal direction of the screen which indicating CURSOR1 and CURSOR2 3 Press the F2 menu selection button and choose CH1 for Source 4 Adjust the positions of CURSOR1 and CURSOR2 according to the measured wave form with the absolute value of the voltage amplitude difference between ...

Page 62: ...yed along the vertical direction of the screen which indicating Cursor 1 and Cursor 2 3 Press the F2 menu selection button and choose CH1 for Source 4 Adjust the positions of CURSOR1 and CURSOR2 according to the measured wave form with the cycle and frequency of Cursor1 and Cursor 2 displayed in the increment window The current position of Cursor1 is displayed in the Cursor1 window and that of Cur...

Page 63: ...per division Trigger Type Current Trigger Source Show the minimum number of channels Trigger Coupling Current Trigger Slope Current Trigger Level Mid point Setting Trigger Mode Auto Display Format YT RUN STOP Enable or disable the waveform sampling Notice Under the Stop state the vertical division and the horizontal time base of the wave form can be adjusted within a certain range in other words t...

Page 64: ...s till the waveform meets your requirement 2 Perform Automatic Measurement The oscilloscope can measure most displayed signals automatically Complete the following operations for the measurement of frequency cycle mean and peak to peak value 1 Press the MEASURE button to show the automatic measurement function menu 2 Press the F1 menu selection button and choose Source with the Source menu display...

Page 65: ...d the CH2 channel to the output end Operation Steps 1 Push down the AUTOSET button and the oscilloscope will automatically adjust the waveforms of the two channels into the proper display state 2 Push down the MEASURE button to show the MEASURE menu 3 Press the F1 menu selection button and choose Source 4 Press the F2 menu selection button and choose CH1 5 Press the F3 menu selection button and ch...

Page 66: ...in Fig 54 Wave Form of Gain Measurement Example 3 Capture the Single Signal The digital storage oscilloscope takes the lead in providing the convenience capturing of such non periodic signals as pulse and burr etc If you intent to capture a single signal you can not set the trigger level and the trigger edge unless you have particular priori knowledge of this signal For example if the pulse is the...

Page 67: ...Rising as the slope 9 Rotate the LEVEL knob and adjust the trigger level to the mid value of the signal to be measured 10 If the Trigger State Indicator at the top of the screen does not indicate Ready push down the RUN STOP button and start Acquire waiting the emergence of the signal in conformity with the trigger conditions If a signal reaches to the set trigger level one sampling will be made a...

Page 68: ...rcuit For the analyzing of the noise in detail please operate the instrument according to the following steps 1 Press the ACQUIRE button to display the ACQU MODE menu 2 Press the F2 menu selection button and choose Peak Detect In this case the screen display contains the wave form of a random noise Especially when the time base is set as Low Speed then noise peak and burr contained in the signal c...

Page 69: ...rate the instrument according to the following step 1 Press the ACQUIRE button to show the ACQU MODE menu 2 Press the F3 menu selection button and choose Average 3 Press the F4 menu selection button and observe the wave form obtained from averaging the wave forms of different average number After the averaging the random noise is reduced and the detail of the signal is easier to be observed Shown ...

Page 70: ...e circuit For the examination of the input and output of the circuit in the form of X Y coordinate graph please operate according to the following steps 1 Set the probe menu attenuation coefficient for 10X and that of the switch in the probe for 10X 2 Connect the probe of channel 1 to the input of the network and that of Channel 2 to the output of the network 3 Push down the AUTOSET button with th...

Page 71: ...Fig 58 Lissajous Graph Based on the expression sinq A B or C D where q is the phase difference angle and the definitions of A B C and D are shown as the graph above As a result the phase difference angle can be obtained namely q arcsin A B or arcsin C D If the principal axis of the ellipse is in the I and III quadrants the determined phase difference angel should be in the I and IV quadrants that ...

Page 72: ...larity 4 Press the F3 menu selection button and choose CH1 for Source 5 Press the F4 menu selection button and choose Field for Sync 6 Adjust the VOLTS DIV VERTICAL POSITION and SEC DIV knobs to obtain a proper wave form display see Fig 59 Fig 59 Wave Form Obtained from Video Field Trigger Video Line Trigger For the trigger in the video line please operate according to the following steps 1 Push d...

Page 73: ...menu selection button and choose CH1 for Source 5 Press the F4 menu selection button and choose Line for Sync 6 Adjust the VOLTS DIV VERTICAL POSITION and SEC DIV knobs to obtain the proper wave form display see Fig 60 Fig 60 Wave Form Obtained from the Video Line Trigger 73 ...

Page 74: ...e signal acquisition operation again 3 The measured voltage amplitude value is 10 times greater or smaller than the actual value Check whether the channel attenuation coefficient conforms and the attenuation ration of the probe used in practical application is match 4 There is wave form displayed but it is not stable z Check whether the Source item in the TRIG MODE menu is in conformity with the s...

Page 75: ...5 open the system function menu and execute the Auto calibration procedure All specification standards can be fulfilled except one s marked with the word Typical Sampling ACQU Mode Sample Peak Detection Average Sampling Rate 250 MS s Input Input Coupling DC AC Input Impedance 1MΩ 2 connected with 20pF 5pF in parallel Probe attenuation coefficient 1X 10X 100X 1000X Max Input Voltage 300V Peak Value...

Page 76: ...5V div at the input BNC Displacement Range 50V 500mV 5V 2V 5mV 200mV Simulative Bandwidth 60M Single Bandwidth Full Bandwidth Low frequency respond AC Coupling 3dB 5Hz at BNC Rising Time Typical at BNC 5 8ns DC Gain Accuracy 5 DC Measuring Accuracy Average for ACQU MODE The voltage difference V between any two points on the wave form after averaging the captured wave forms of more than 16 5 Readin...

Page 77: ...Late Trigger 4 divisions Set Level to 50 Typical Operation under the condition of input signal frequency 50Hz Internal Peak to peak value of 2 divisions EXT 400mV Trigger Sensitivity Video trigger typical EXT 5 2V Signal System and Line Field Frequency Video Trigger Type Supporting the NTSC PAL and SECAM broadcast system of any field frequency of line frequency Measurement Cursor Measurement Volta...

Page 78: ...eak value equal to or greater than 1MΩ of load Frequency Typical Square wave of 1KHz Power Mains Voltage 100 240 VAC RMS 50Hz CAT II Power Consumption 15W Fuse 1A T grade 250V Environment Temperature Working temperature 0 40 Storage temperature 20 60 Relative Humidity 90 Height Operating 3 000 m Non operating 15 000 m Cooling Method Natural convection Mechanical Specifications Dimension 350mm 157m...

Page 79: ...leaning Check the probe and instrument regularly according to their operating state Clean the external surface of the instrument following the steps shown below 1 Please wipe the dust from the instrument and probe surface with a soft cloth Do not make any scuffing on the transparent LCD protection screen when clean the LCD screen 2 Clean the instrument with a wet soft cloth not dripping water duri...

Page 80: ...ttery power indication show on the top of panel when oscilloscope power supplied by the battery and imply for different power consumption and when shows it means the power can only supply for 5 minutes maximum Note To avoid superheat of battery during charging the environment temperature is not allowed to exceed the permissible value given in technical specification Replacing the Lithium Battery U...