background image

Model / Modèle

Metrop 5144-2675O
Forma 5152-2565O

http://www.owlee.com/technical-information.aspx

DANGER

This gas appliance is designed as an “attended appliance”.  Adults must be present when the unit is 
operating/burning.  

DO NOT leave this unit operating/burning when unattended.

  If this product is left 

operating/burning and unattended it may cause serious injury, death and or property damage.

CASUAL FIRESIDE

Installation and service must be performed by a qualified installer, service agency, or the gas supplier

FIRE OR EXPLOSION HAZARD

1.  Shut off gas supply to the appliance.

If you smell a rotten egg odor immediately:

INSTALLER

  - Leave this manual with the 

appliance.

CONSUMER

 –  Retain this manual for 

future reference.

CARBON MONOXIDE HAZARD

This appliance can produce carbon monoxide 
which has no odor.

Using it in an enclosed space can kill you.

Never use this appliance in an enclosed space 
such as a camper, tent, car or home

.

Failure to follow these instructions 
could result in fire or explosion, 
which could cause personal injury, 
death or property damage,

3.  If odor continues, leave the area immediately.
4.  After leaving the area, call your gas supplier 
or fire department.

2.  Extinguish any open flame.

        DANGER

Tested & Certified to

 ANSI Z21.97-2017/CSA 2.41-2017

CGA 2.17-M91 (R2017)

The link below will take you to the Owners Manual and Operating Instructions in French where you can download a copy.
Sélectionnez le lien ci-dessous pour télécharger les instructions françaises.

A HIGHER STANDARD IN QUALITY AND APPEARANCE - SAFE AND BEAUTIFUL OUTDOOR

FIRE PIT FOR PROPANE AND NATURAL GAS 

(Requires Conversion Kit)

Report #14662-1G

WARNING

Improper installation, adjustment, alteration, service or maintenance of this gas appliance can cause 
injury, death or property damage.  Read the installation, operating and maintenance instructions 
thoroughly before installing or servicing this gas appliance.

WARNING

To avoid risk of fire or explosion.  Do Not store or use gasoline, or other flammable vapors and liquids, in 
the vicinity of this or any other gas appliance.  An LP-cylinder not connected for use shall not be stored in 
the vicinity of this or any other gas appliance.

WARNING:  FOR OUTDOOR USE ONLY

APPLIANCE BTU RATING

65,000 Propane / 65,000 Natural Gas

BUILDING CODE AND FIXED PIPING SUPPLY REQUIREMENTS:   When an appliance is connected to a fixed gas piping supply 
system, the installation must conform to local building codes, or in the absence of local building codes, to the National Fuel Gas 
Code, ANSI Z223.1/NFPA 54, International Fuel Gas Code, Natural Gas and Propane Installation Code, CSA B149.1, or Propane 
Storage and Handling Code, B149.2, as applicable.

READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT.

If the information in this manual is not followed exactly, a fire or explosion may result causing

personal injury, death or property damage.

V6-100119A

Summary of Contents for 5152-2565O

Page 1: ...rating Instructions in French where you can download a copy S lectionnez le lien ci dessous pour t l charger les instructions fran aises A HIGHER STANDARD IN QUALITY AND APPEARANCE SAFE AND BEAUTIFUL...

Page 2: ...Y THIS UNIT MUST BE INSTALLED AT LEAST 60 FROM CENTER OF BURNER TO ANY COMBUSTIBLE WALLS CEILINGS OR MATERIAL WHEN SHUTTING OFF THE UNIT BE SURE TO TURN THE CONTROL VALVE ON THE FIRE PIT TO THE FULLY...

Page 3: ...pit and it must be closed during any pressure testing of the system at test pressures in excess of psi 3 5kPa C CHECK GAS TYPE Natural Gas or Propane The gas supply you intend to use may not be the s...

Page 4: ...near the appliance O DO NOT use this appliance if any part of it has been under water Call a qualified service technician to inspect the appliance and to replace any part of the control system and any...

Page 5: ...e LP Gas Cylinders must be stored outdoors in a well ventilated area out of the reach of children at Least 60 inches away for the fire pit Disconnected cylinders must have threaded valve caps tightly...

Page 6: ...ves and connections to make sure they do not leak before lighting appliance Contact with the liquid contents of the cylinder will cause freeze burns to the skin Do not allow children to tamper or play...

Page 7: ...9 19mm 12 Crushed Fire Glass Kit Size 1 2 3 4 12 20 mm 13 Mirrored Glass Kit Size 1 4 6 35mm 14 Lava Granules 3 8 15 Ceramic Rock Kit with Lava Granules PROTECTIVE SCREEN MEDIA PLACEMENT Media placem...

Page 8: ...e to expand and cause a pop and launch outside of the fire pit which could cause injury or property damage Allow lava granules to completely dry after getting wet rained on or hosed off before lightin...

Page 9: ...ME AFTER USE YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW M...

Page 10: ...ferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctl...

Page 11: ...ions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor...

Page 12: ...service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS STOP READ SAFETY INFORMATION ABOVE 1 Ens...

Page 13: ...for various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemicals...

Page 14: ...nd replace it with the proper sized one for your gas requirement Propane requires the smaller orifice 4 If you are converting from propane LP gas to natural gas install the air shutter sleeve so that...

Page 15: ...s lieux appelez votre fournisseur de gaz ou le service d incendie DANGER Cet appareil gaz est con u comme un appareil surveill Les adultes doivent tre pr sents lorsque l unit est en fonctionnement en...

Page 16: ...CE MANUEL LIQUIDATION MINIMUM DE COMBUSTIBLES Figure 1 Page 2 PUITS D INCENDIE EXTERIEUR TABLE DES MATIERES INFORMATIONS IMPORTANTES SUR LA S CURIT LIRE CES INSTRUCTIONS ENTI REMENT AVANT D INSTALLER...

Page 17: ...rie du gaz doit tre dimensionn de sorte fournir la pression minimale d admission au d bit maximum BTU hr Une perte excessive de pression se produira si le tuyau est trop petit ou trop long G Casual Fi...

Page 18: ...llation et les r parations doivent tre effectu es par un technicien qualifi L appareil doit tre inspect avant utilisation et au moins une fois par an par un technicien qualifi Un nettoyage plus fr que...

Page 19: ...nne filet s doivent tre bien install s dans les bouteilles d connect es et ne doivent pas tre entrepos s dans un b timent un garage ou un autre espace clos 6 La bouteille de gaz GPL doit reposer sur l...

Page 20: ...ne fuient pas avant d allumer l appareil Le contact avec le liquide contenu dans la bouteille provoquera des br lures de la peau dues au gel Ne laissez pas les enfants alt rer ou jouer avec le cylind...

Page 21: ...gaz naturel n 9 cran de protection 09 n 10 Thermocouple 10 n 11 Ensemble de verres galets Taille 3 4 1 2 9 19mm n 12 Ensemble de vitre coupe feu n Taille 1 2 3 4 12 20 mm n 13 Trousse de vitre miroir...

Page 22: ...TS EN VERRE GEM MIROIR ET BROY Versez le support en miroir la pierre pr cieuse ou le verre pil dans le Br leur de foyer ext rieur afin que le br leur soit couvert REMARQUE Voir page 7 pour le d gageme...

Page 23: ...provoquer une expansion des gaz pi g s ou de l humidit et provoquer un clatement et un lancement pourrait causer des blessures ou des dommages mat riels Laissez les granules de lave s cher compl temen...

Page 24: ...ans le venturi et orifices des trous pour d gager le passage libre des toiles d araign es ou d autres d bris Assurez vous de tout remettre correctement lorsque vous avez termin pour le fonctionnement...

Page 25: ...ant Parties Pit Fire O W Lee offre une garantie limit e de deux 2 ans sur tous les composants du br leur en utilisation normale et appropri e entretien OW Lee sera l usine de r parer ou de remplacer t...

Page 26: ...ande du foyer et la soupape du r servoir de propane sont ferm es 2 Attendez au moins 5 minutes que le gaz se vide MODE D EMPLOI Nous vous recommandons de vous familiariser avec le sch ma de la vanne d...

Page 27: ...ue r pertori de la Proposition 65 La combustion de propane dans des appareils tels que des po les ou des syst mes de chauffage et des v hicules utilisant du propane cr e des produits chimiques nocifs...

Page 28: ...ce que les orifices d admission d air soient ferm s Figure 2 Pour le gaz propane retirez l obturateur d air de fa on ce que les orifices d admission d air soient ouverts Figure 1 Une fois que l unit e...

Reviews: