Operating Environment
Maximum Storage Capacity and Data Transfer Rates
Numbers for the 1U, 2U, and 4U models. Host interface is 6 Gb/s (SAS) and 8 Gb/s (FC).
Environment
Characteristics
Specification
Operating
Temperature
10°C to 35°C
Max. temperature rise
10°C / hour
Humidity
20% to 80% R.H. (non condensing)
Maximum wet bulb
26°C
Max. humidity rise
10% / hour
Altitude operating
0 to 10.000 ft (3000 m) at 25°C ambient
Non Operating
Storage and
Shipping
Temperature
-30 °C to +60°C
Max. temperature rise
20°C / hour
Humidity
10% to 90% RH (non condensing)
Altitude
-22 to 33000 feet (-7 to 10000 m)
Characteristics
Specification
NEO S-Series tape library with LTO-5 drives
Maximum storage capacity
(8/24/48 data cartridges)
Native 12/36/72 TB
Compressed: 24/72/144 TB
(assuming 2:1 compression)
Maximum data transfer rate
(single LTO-5 drive)
Native: 140 MB/s (504 GB/h)
Compressed: 280 MB/s (1 TB/h)
(assuming 2:1 compression)
NEO S-Series tape library with LTO-6 drives
Maximum storage capacity
(8/24/48 data cartridges)
Native 20/60/120 TB
Compressed: 50/150/300 TB
(assuming 2.5:1 compression)
Maximum data transfer rate
(single LTO-6 drive)
Native: 160 MB/s (576 GB/h)
Compressed: 389 MB/s (1.4 TB/h)