![Overland Tandberg NEO S 1U Service Manual Download Page 26](http://html1.mh-extra.com/html/overland-tandberg/neo-s-1u/neo-s-1u_service-manual_1663113026.webp)
NEO S-Series Library Service Manual
Replacing Parts
10400666-005
©2015-20 Overland-Tandberg
26
6.
Use the OCP or RMI to upload the firmware upgrade.
•
From OCP, select
Main Menu > Service > Service Library > FW Upgrade by USB.
•
From RMI, select
Service > Firmware > Upgrade Library Firmware > Upgrade.
7.
Click
Browse
to select the firmware file.
8.
Click
Upload
.
9.
Once the update is complete,
verify
the firmware version.
Add or Replace a Power Supply
WARNING:
To reduce the risk of electric shock or damage to equipment, always remove any
power cords while working with the library.
WARNUNG:
Um das Risiko eines elektrischen Schlags oder Schäden am Gerät zu vermeiden,
ziehen Sie stets den Netzstecker, bevor Sie an der Einheit arbeiten.
AVERTISSEMENT:
Pour réduire le risque de choc électrique ou endommagement de l'équipement, retirez
toujours les cordons électriques en travaillant avec l'appareil.
CAUTION:
While working with the library, observe standard Electrostatic Discharge (ESD)
precautions to prevent damage to micro-circuitry or static-sensitive devices.l
The power supply unit (PSU) bays are located at the rear of the library.
•
2U library – There is only one power supply bay.
•
4U library – There are two power supply bays. Always install the first power supply in
the lower bay.
The unit can run with one power supply. If redundant a power supply is desired for fault
tolerance, install a second power supply in the bay directly above the existing power supply.
Add a Redundant Power Supply
NOTE: If you are replacing an existing power Supply, proceed with
.
1.
Verify that all host processes are
idle
and power off the library by depressing the
power
button
on the front panel.
2.
Using a Phillips screwdriver, remove
the
three screws
securing the cover plate on the
upper power supply bay.
Set the
cover plate and screws
aside, saving them for possible future use.
3.
Position the
new power supply
onto the alignment rails in the bay.
4.
Slide the
power supply
into the library until it is flush with the back panel of the
library.