10400414-002 05/2013
©2013 Overland Storage, Inc.
4-10
SnapSAN S5000 Data Migration User Guide
Main options
The iSMmc_setconfig command recognizes the following options:
Data migration speed level specification (-level level)
Specify the speed level of data migration. For level, specify a value from 1 to 5. Data
migration processing is given priority corresponding to the specified level, with level 5 as the
highest level. The default value is 3.
List (-list)
Displays the data migration environment setting values.
Displayed information
The following information is displayed.
Description
disk_array_name: Displays the disk array name.
level: Displays the speed level set to the displayed disk array.
Changing the Data Migration Settings
The iSMmc_change command changes the data migration speed level settings
Main options
The iSMmc_change command recognizes the following options:
Source logical disk specification (-src src -srcflg srcflg)
Specify the source logical disk and its volume type.
Data migration speed level specification (-level level)
Specify the speed level of data migration. For level, specify a value from 1 to 5. Data
migration processing is given priority corresponding to the specified level, with level 5 as the
highest level. If this option is omitted, the value specified in environment setting is assumed
to be specified.