10400414-002 05/2013
©2013 Overland Storage, Inc.
3-6
SnapSAN S5000 Data Migration User Guide
During Migration
Make FC connection during migration processing, if it is impossible to add FC
connection here.
a.
When migrating the disk array only from the environment where the application
server and the source disk array are connected directly through FC.
•
If the source and destination disk arrays individually have one or more empty host
connection ports, the source disk array and the destination disk array can be
connected.
•
It is not usually allowed to add FC connection between the application server and
the destination disk array.
b.
When migrating the disk array only from the environment where the application
server and the source disk array are connected via the FC switch.
•
If the destination disk array has one or more empty host connection ports and the
FC switch has one or more empty ports, the source disk array and the destination
disk array as well as the application server and the destination disk array can be
connected.
c.
When migrating the disk array and the application server from the environment
where the application server and the source disk array are connected directly
through FC.
•
If the source and destination disk arrays individually have one or more empty host
connection ports, the source disk array and the destination disk array can be
connected.
•
If the destination disk array has still one or more empty host connection ports, the
application server and the destination disk array can be connected.