Page 1: ...ORAL APPLIANCE FOR SLEEP APNOEA THERAPY O2VENT OPTIMA INSTRUCTIONS FOR USE AUSTRALIA...
Page 2: ...Name of User Name of Sleep Physician Name of Dentist Serial No of Device Date of first fitting purchase Connector band starting titration length Date of follow up with Physician Dentist...
Page 3: ...our Optima Device Works 5 Using your Optima 8 Inserting your Optima 8 Removing your Optima 8 Finding the right titration setting 9 What are the Risks of OSA 11 Contraindications 11 Cleaning Instructio...
Page 4: ...xperiences repetitive episodes of partial or complete blockage of the upper airway during sleep This is caused by obstructions of the nose soft palate and tongue The Optima is a removable oral applian...
Page 5: ...fore assembly lower tray upper tray and connector bands Optima fully assembled Your Optima features the following components OPTIMA DESCRIPTION Upper tray with airway Connector band Lug for attaching...
Page 6: ...The size is marked on the band Oventus tub Instructions for use Warranty Antibacterial cleanser tablets It is important that you check the contents of your personalised Optima kit and make sure that...
Page 7: ...f nasal congestion or difficulties with breathing through the nose Brings pulls the lower jaw forward this opens the airway and stabilises the tongue The air channel allows the air to flow smoothly to...
Page 8: ...ow Hollow airway bypasses multiple obstructions In order manufacture the Optima an image of the teeth using 3D scanning or impressions are taken The information is sent to a laboratory where your cust...
Page 9: ...nt lengths to enable titration adjustment There are 9 length size options ranging from 13 21mm Your new Optima is delivered fully assembled with the 19mm connector band as the recommended starting tit...
Page 10: ...ake sure your Optima is clean 4 Rinse the Optima and brush your teeth before inserting 5 Using your thumbs insert the upper tray and gently push onto the upper teeth the tray should fit snugly 6 Inser...
Page 11: ...riod according to your Healthcare Professional recommendations Ensure the connector band lengths are the same on each side The titration may take several weeks or longer to achieve the best therapy If...
Page 12: ...is a guide only The recommended starting titration for new users in most instances is the 19mm connector bands NOTE The shorter the connector band the further the lower jaw is advanced The longer the...
Page 13: ...sk of motor vehicle and workplace accidents WHAT ARE THE RISKS OF OSA The Optima device is contraindicated for patients who Have central sleep apnoea Have severe respiratory disorders Have loose teeth...
Page 14: ...device after each cleaning with a clean tissue or towel and shake to clear water from the airway Return to the Oventus tub to store with the lid open to allow the internal airway to dry RECOMMENDED TW...
Page 15: ...airway entry and exit points to remove the cleaning agent Dry your device after each cleaning with a clean cloth Return to the Oventus tub to store with the lid open to allow the internal airway to d...
Page 16: ...leep period Permanent bite change may occur as a result of long term use If any side effects or ongoing dental issues persist while using the Optima please seek advice from your Healthcare Professiona...
Page 17: ...ve determined the band length that optimises your therapy you can re order them in packs of 25 To re order the connector bands ask your Health Professional or visit www oventus com au The Optima conne...
Page 18: ...t a new band If the bands are longer or the holes stretch from circular to oval it is time to change both bands To remove a connector band from your Optima device pull the upper and lower device piece...
Page 19: ...ntry may be weekly or daily It may take several weeks or longer to achieve the best therapy Refer to page 10 for the lower jaw positioning range as a guide Date Connector band length Comment EXAMPLE 1...
Page 20: ...ventus Warranty Policy Card included with your device MANUFACTURER AND AUSTRALIAN SPONSOR Oventus Manufacturing Pty Ltd 1 Swann Road Indooroopilly QLD 4068 Australia Ph 61 1300 533 159 Toll free only...