background image

 
Setup

 

-6- 

 

Ovation E-910FC User Manual Rev. 8 

3. Setup 

AC Power 

Each  Ovation E-910FC  has an auto-ranging power supply that works with an input voltage 
range of 100  to  240 VAC, 50/60 Hz. To determine the power requirements for each  
Ovation E-910FC, refer to the label affixed to the product. You can also refer to the 

Technical 

Specifications

 chart in this manual. 

The listed current rating indicates the maximum current draw during normal operation. For more 
information, you may download Sizing Circuit Breakers from the Chauvet  website: 

www.chauvetprofessional.com

. 

 

 

Always connect this product to a protected circuit with an appropriate electrical 
ground to avoid the risk of electrocution or fire. 

 

To eliminate unnecessary wear and improve its lifespan, during periods of non-use 
completely disconnect the product from power via breaker or by unplugging it. 

 

Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if the 
rheostat or dimmer channel serves only as a 0 to 100% switch. 

AC Plug 

The  Ovation E-910FC  comes with a power input cord terminated with a Neutrik powerCON A 
connector on one end and an Edison plug on the other end (U.S. market). If the power input 
cord that came with your product has no plug, or if you need to change the Edison plug, use the 
table below to wire the new plug. 

 

Connection 

Wire (U.S.) 

Wire (Europe) 

Screw Color 

AC Live 

Black 

Brown 

Yellow or Brass 

AC Neutral 

White 

Blue 

Silver 

AC Ground 

Green/Yellow 

Green/Yellow 

Green 

 

Power Linking 

The  Ovation E-910FC  supports power linking. You can power link up to 6  products at  
120 V; up to 11 at 208 V; or up to 12 at 230 V. 
This product comes with a power input cord. Power linking cables are available from Chauvet 
for purchase. 

Fuse 

Replacement 

1.  Disconnect this product from the power outlet. 
2.  Using a Phillips-head screwdriver, unscrew the fuse holder cap from the housing. 
3.  Remove the blown fuse and replace with another fuse of the same type and rating  

(T 3.15 A, 250 V). 

4.  Screw the fuse holder cap back in place and reconnect power. 

 

Make sure to disconnect the product’s power cord before replacing a blown fuse. Always 
replace the blown fuse with another of the same type and rating. 

 
 

 

Summary of Contents for E-910FC

Page 1: ...User Manual Lens tubes sold separately...

Page 2: ...thout written consent from Chauvet Document Printing For better results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure your printer...

Page 3: ...ice Management RDM 7 Master Slave Connectivity 7 Mounting 8 Orientation 8 Rigging 8 Procedure 8 Manual Beam Focus Control 9 Rotating the Barrel Assembly 9 Accessory Slot 9 4 Operation 10 Control Panel...

Page 4: ...r Manual Rev 8 5Ch 17 3Ch 17 Virtual Color Wheel 18 Color Chart 18 Preset Color Temperature Chart 19 5 Technical Information 20 Product Maintenance 20 Cleaning the Light Engine Lens 20 6 Technical Spe...

Page 5: ...issues such as missing components or parts damage not related to shipping or concealed damage file a claim with Chauvet within 7 days of delivery Manual Conventions Convention Meaning 1 512 A range o...

Page 6: ...ing When hanging this product always secure to a fastening device using a safety cable Power And Wiring Always make sure you are connecting this product to the proper voltage in accordance with the sp...

Page 7: ...control 16 bit dimmer strobe virtual color wheel color temperature 12 channel RGBAL control dimmer strobe virtual color wheel color temperature auto programs auto speed dimmer mode 13 channel 16 bit...

Page 8: ...lot Bottom View A size holder for 3 in patterns B size holder for 2 5 in and 2 75 in patterns sold separately Barrel Rotation Knobs Beam Focus Knobs Lens Tube sold separately Barrel Assembly Light Eng...

Page 9: ...Introduction Ovation E 910FC User Manual Rev 8 5 Dimensions 19 35 in 491 mm 6 86 in 174 mm 6 77 in 172 mm 11 17 in 283 mm 25 90 in 657 mm 19 15 in 486 mm 23 33 in 592 mm...

Page 10: ...0 to 100 switch AC Plug The Ovation E 910FC comes with a power input cord terminated with a Neutrik powerCON A connector on one end and an Edison plug on the other end U S market If the power input c...

Page 11: ...Remote Device Management RDM Remote Device Management or RDM is a standard for allowing DMX enabled devices to communicate bi directionally along existing DMX cabling Check the DMX controller s User M...

Page 12: ...ion may affect the product If hanging this product make sure that the mounting location can support the product s weight See the Technical Specifications for the weight bearing requirements of this pr...

Page 13: ...tate the barrel to the desired position up to 25 in either direction from the centered position 4 Tighten the knobs by turning them clockwise which lock the barrel s position Make sure the barrel asse...

Page 14: ...the current programming level press UP or DOWN until the option shows on the display Press ENTER to select In this case if there is another programming level you will either see that first option or y...

Page 15: ...C1650 Magenta C6170 Dk Magenta C6020 Lt Lavender C5030 Lt Blue C5020 VLt Blue C5430 Lt Blue 2 C5070 Blue C5050 Md Blue C5060 Dk Blue C5690 Indigo C5080 VDk Blue C5081 VDk Blue 2 C4370 Yel Green C4070...

Page 16: ...maximum value Green Sets green LED maximum value Blue Sets blue LED maximum value LED Frequency 600Hz Selects the PWM output frequency 1200Hz 2000Hz 4000Hz 6000Hz 25KHz Fan Mode Auto Sets the fan to...

Page 17: ...n gel colors To select a gel color do the following 1 Go to the Virtual Color Wheel main level 2 Select Virtual Color Wheel 3 Select the desired color See the Virtual Color Wheel Chart section 4 Press...

Page 18: ...or Blue 4 Select a color value 125 255 5 Repeat for the other colors LED Frequency This option changes the Pulse Width Modulation PWM frequency of the LEDs on the Ovation E 910FC 6 Go to the LED Freq...

Page 19: ...the Master Slave main level b Select the Master programming level 3 Set the starting address a Go to DMX Address main level b Select the starting address 001 512 The highest recommended starting addr...

Page 20: ...100 2 Red 000 255 0 100 3 Green 000 255 0 100 4 Blue 000 255 0 100 5 Amber 000 255 0 100 6 Lime 000 255 0 100 7 Strobe 000 010 011 255 No function Strobe slow to fast 8 Virtual Color Wheel 000 255 Ref...

Page 21: ...rt section for specific values 7Ch Channel Function Value Percent Setting 1 Dimmer 000 255 0 100 2 Red 000 255 0 100 3 Green 000 255 0 100 4 Blue 000 255 0 100 5 Amber 000 255 0 100 6 Lime 000 255 0 1...

Page 22: ...226 227 234 235 242 243 250 251 255 C3050 Md Yellow C3040 Lt Yellow C3240 Amb Yellow C2340 VLt Amber C2040 Lt Amber C2050 Md Amber C2060 Dk Amber C1050 Lt Red C1080 Md Red C1020 NC Pink C1030 Md Pink...

Page 23: ...00K 4000K 4500K 5000K 5600K 6000K 6500K 000 255 253 234 204 181 160 138 147 142 000 000 199 247 255 255 248 255 255 255 251 000 000 107 129 141 156 166 180 191 193 197 000 000 253 255 253 243 224 241...

Page 24: ...cleaning tissue 6 Wipe any dirt or grime to the outside edges of the lens surface 7 Gently polish the lens surfaces until they are free of haze and lint Always dry the external surfaces thoroughly and...

Page 25: ...ik powerCON A Neutrik powerCON A Power output connector Neutrik powerCON B Neutrik powerCON B Power cord plug Edison U S Local plug Light Source Type Power Lifespan LED 3 W 50 000 hours Color Quantity...

Page 26: ...MA number Chauvet will refuse any product returned without an RMA number DO NOT write the RMA number directly on the box Instead write it on a properly affixed label Once you have received the RMA num...

Page 27: ...www chauvetlighting eu General Information Chauvet Europe Ltd Address Unit 1C Brookhill Road Industrial Estate Pinxton Nottingham UK NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Technical Sup...

Page 28: ...User Manual Ovation E 910FC User Manual Rev 8...

Reviews: