9
8.2 Haftung
Der Hersteller haftet, wenn das Produkt gemäß den Beschreibungen und Anweisungen in diesem
Dokument verwendet wird. Für Schäden, die durch Nichtbeachtung dieses Dokuments, insbe
sondere durch unsachgemäße Verwendung oder unerlaubte Veränderung des Produkts verur
sacht werden, haftet der Hersteller nicht.
8.3 CE-Konformität
Das Produkt erfüllt die Anforderungen der Verordnung (EU) 2017/745 über Medizinprodukte. Die
CE-Konformitätserklärung kann auf der Website des Herstellers heruntergeladen werden.
1 Foreword
English
INFORMATION
Date of last update: 2020-11-11
►
Please read this document carefully before using the product and observe the safety
notices.
►
Obtain instruction from the qualified personnel in the safe use of the product.
►
Please contact the qualified personnel if you have questions about the product or in case of
problems.
►
Report each serious incident related to the product to the manufacturer and to the relevant
authority in your country. This is particularly important when there is a decline in the health
state.
►
Please keep this document for your records.
These instructions for use provide you with important information for properly applying and remov
ing the
Tübingen Hip Flexion and Abduction Orthosis according to Prof. Bernau
and for
correctly adapting it to the patient.
2 Product Description
2.1 Components (see Fig. 1)
Item Designation
Item Designation
1
Shoulder harness with terry cloth covers 6
Push-pull device for spreader bar (red)
2
Hook-and-loop closure with caterpillar
graphic
7
Spreader bar with ratchet mechanism
3
Front closures (white)
8
Back closures (red)
4
Beaded cords (green/white)
9
Lower closures (red)
5
Thigh shells
–
2 terry cloth covers and 1 hook-and-loop
closure are included as replacements
2.2 Design
The thigh shells (5) and the shoulder harness (1) are joined together by green/white beaded
cords, which are held by the white closures (3) and the red closures (8, 9). The hook-and-loop
closure (2) and the white closures (3) on the front of the shoulder harness (1) are used when put
ting on and taking off the Tübingen Hip Flexion Orthosis.
The attending physician can change the length of the beaded cords (4) with the red closures (8,
9) on the shoulder harness (1) and on the thigh shells (5). This establishes the hip flexion position
and can be adjusted as the infant grows.
After loosening the push-pull device (6) on the spreader bar (7), the two sections of the spreader
bar (7) can be simultaneously adjusted to achieve the desired hip abduction. The numbered scale
on the bottom of the spreader bar (7) makes it easy to duplicate the setting.
Summary of Contents for 28L10
Page 2: ...1 2 3 4 5 2...
Page 3: ...30 45 90 6 7 8 9 10 11 3...
Page 73: ...73 3 3 1 28L10 1 3 2 1 IIa IIb IIc 3 3 3 4 1 3 5 90 5 1 2 4 7 4 4 1 4 2 1 1 1 2...
Page 82: ...82 3 4 T binger 1 3 5 90 T binger 5 1 2 4 7 4 4 1 4 2 1 1 1 2 8 9 7 5 5 1 T binger 3 5 2...
Page 85: ...85 7 8 8 1 8 2 8 3 CE 2017 745 1 2020 11 11 2 2 1 1 1 6 2 7 3 8...
Page 87: ...87 4 4 1 4 2 1 1 1 2 8 9 7 5 5 1 3 5 2 2 3 1 2 3 4 3 5 4 2...
Page 89: ...89 8 1 1 4 8 2 4 3 4 8 12 4 90 13 5 4 2 3 1 2 3 2 4 6 1 2 1 2 15 2 1 3 2 40 C 4 5 1 2 7 8...
Page 90: ...90 8 1 8 2 8 3 2017 745 CE 1 2020 11 11 2 2 1 1 1 6 2 7 3 8 4 9 5 2 1 2 2 5 1 3 8 9 1 2 3...
Page 98: ...98 8 2 8 3 CE 2017 745 CE...
Page 99: ...99...
Page 100: ...100...
Page 101: ...101...