OTO Photonics LS-DH-1 Operation Manual Download Page 1

OtO Photonics 

Light Source Operation Manual  

Deuterium-Halogen Light Series  
(LS-DH Series) 

 

LS-DH-1 
LS-DH-2 
LS-DH-3 

 

LS-DH Series Operation Manual-801 Rev.1 

www.otophotonics.com 

 

www.aptechnologies.co.uk

AP 

Technologies Limited   The Coach House   Watery Lane   Bath   BA2 1RL 

T:  +44 (0) 1225 780400    F:  +44 (0) 8701 266449    E:  info@aptechnologies.co.uk 

Summary of Contents for LS-DH-1

Page 1: ...ight Series LS DH Series LS DH 1 LS DH 2 LS DH 3 LS DH Series Operation Manual 801 Rev 1 www otophotonics com www aptechnologies co uk AP Technologies Limited The Coach House Watery Lane Bath BA2 1RL...

Page 2: ...m P3 Operation Selection Features P4 Manual Mode Operation P4 Auto Mode Operation P5 I O Extension Port Pin Description Alt Function P6 Spectrum P7 LS DH Series Operation Manual 801 Rev 1 www aptechno...

Page 3: ...ies Measurement Platform LS DH Series Operation Manual 801 Rev 1 Deuterium Halogen Light Series Operation Manual www aptechnologies co uk AP Technologies Limited The Coach House Watery Lane Bath BA2 1...

Page 4: ...ED will be lightening ON Step 2 Then user can select the Auto Manual Switch Once the manual mode is selected that means the switch is at the left position Step 3 After manual mode is selected user can...

Page 5: ...er Switch The Power Green LED will be lightening ON Step 5 Slide the Auto mode switch to the right position The Auto Green LED will be lightening ON Step 6 Then user can use the OtO s software Spectra...

Page 6: ...h connector with every DH light source This 8pin connector can connect SmartEngine SE series spectrometer and DH light source directly to operate auto mode Once the operation mode is selected to Auto...

Page 7: ...m and Halogen light source on measured by OtO EE2061 spectrometer LS DH Series Operation Manual 801 Rev 1 Deuterium Halogen Light Series Operation Manual www aptechnologies co uk AP Technologies Limit...

Page 8: ...tly Setting Function Lamp button Software development commands UAI_SpectrometerSetExternalPort and UAI_SpectrometerGetExternalPort can set the operation status of shutter halogen and deuterium lamp GP...

Reviews: